Files
pxe-server/playbook/shopfloor-setup/gea-shopfloor-collections/manifest-entry-controller-credential.json
cproudlock 27045d5e4a gea-shopfloor-collections: controller NIC auto-IP + credential break-glass
04-SetControllerNicIP.ps1 (imaging-time, runs once via Run-ShopfloorSetup):
- Finds the Realtek physical Ethernet adapter (controller NIC on every
  collections bay; corp LAN is Intel)
- Skips any candidate with a DHCP default gateway (that one is the corp
  LAN, not the controller)
- Skips any candidate already on 192.168.1.2
- Sets static 192.168.1.2/24, no gateway, clears DNS - matches the
  manual procedure documented in post-deploy-debug-flowchart.md section 2B
- Refuses to guess when multiple Realtek NICs remain ambiguous
- Imaging-time only, not enforced via GE-Enforce so the tech can override
  on a specific bay if needed without the drift-catcher reverting

Set-ControllerCredential.ps1 + manifest-entry-controller-credential.json:
- Break-glass cmdkey /add for the controller SMB share (\\192.168.1.1\md1
  used by DNC). Scoped to the 12 Okuma LOC650 machine numbers (3201-3212).
- Manifest entry is detection-less so it runs every enforce cycle if the
  script is armed (.ps1 extension); disarmed by default (.ps1.bak on the
  share) so a coach can rename when a bay loses its credential without
  the enforcer overwriting per-bay deviations between events.
- Smoke-tested end-to-end on win11 VM via QGA: SYSTEM context cmdkey /add
  succeeds, cmdkey /list shows the entry. DNC service runs as LocalSystem
  so SYSTEM vault is the right target.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-21 19:38:59 -04:00

9 lines
1.0 KiB
JSON

{
"_comment": "Drop this entry into the SFLD share at \\tsgwp00525\\sfld$\\v2\\shared\\dt\\shopfloor\\gea-shopfloor-collections\\manifest.json (Applications array). Edit Set-ControllerCredential.ps1 first to fill in the real $Username + $Password before pushing the script + manifest. Detection is omitted on purpose: Install-FromManifest treats missing DetectionMethod as 'not installed' and runs the script every enforce cycle, which is exactly what we want (Defender / Intune occasionally scrubs the entry; we re-apply on each cycle). cmdkey /add is idempotent so re-running is harmless. TargetMachineNumbers is optional; remove it to apply to every collections bay, or list specific machine numbers to scope down.",
"Name": "Controller credential for Okuma LOC650 bays (192.168.1.1)",
"PCTypes": ["gea-shopfloor-collections"],
"TargetMachineNumbers": ["3201", "3202", "3203", "3204", "3205", "3206", "3207", "3208", "3209", "3210", "3211", "3212"],
"Script": "apps/Set-ControllerCredential.ps1",
"Type": "PS1"
}