New post-deploy-checklist.md (+ live.html + static.html siblings): - Four-section terse coach checklist run after a freshly imaged PC reaches the login screen. Pairs with the existing post-deploy debug flowchart for failure paths. - Sections: Common Shop Floor opens + connects, controller comms (ping 192.168.1.1 / NTLARS General+FMS), UDC COM port matches physical socket + no machine-comm error dialog + Tools > Retry Connection succeeds, printers ready (Genspect-specific note). post-deploy-debug-flowchart.md: - COM port mapping: PCIe add-in card now listed as 'COM 2 or COM 4' (Windows enumeration varies by hardware) instead of fixed COM 2. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
1.3 KiB
1.3 KiB
Post-Deploy Checklist
Run after first boot. Sign off when all boxes checked. Fail any step, see post-deploy-debug-flowchart.md.
1. Common Shop Floor
Shopfloor ToolsthenWJ Shopflooropens- Login prompt and menu screen render
Fail: check corp network, ping WJFMS3.AE.GE.COM.
2. Controller (skip if standalone PC)
ping 192.168.1.1returns 4 of 4 replies- NTLARS General tab populated
- NTLARS FMS Host Primary set to
WJFMS3.AE.GE.COM(FQDN)
Fail ping, see 2B NIC. Blank General, see 2A reg load.
3. UDC COM port
- UDC opens with no machine-communication error dialog
ToolsthenRetry Connectionsucceeds (no error)- Port Name matches physical port: onboard COM1, PCIe card COM2 or COM4
- Data lines populate after reopen
Fail, see Step 4.
4. Printers (Genspect: all nearby)
Install Printersshortcut opens- Each nearby printer installed, status Ready
- Test page prints
- Genspect: default printer set
Fail, see printer-mapping.md.