Recurring Phase 2 "Device Configuration" stuck: GE Intune Proactive Remediation "Report IP" script enumerates Get-NetIPAddress and POSTs all IPs to a GE webhook. Bays cabled to air-gapped PXE LAN have 10.9.100.x leak into that report. GE backend tags bays "not on corp net" -> dynamic-group assignment-filter at GE excludes them from the SFLD ConfigurationProfile (Function + SasToken OMA-URI) -> HKLM:\SOFTWARE\GE\SFLD\DSC never populates -> Monitor Phase 2 gate never closes. Confirmed via mdm-diag-F907T5X3 dump: every Microsoft policy delivered fine, zero SFLD/GE-namespace OMA-URI present. Fix flow: 1. Run-ShopfloorSetup line 43: disable every Up wired NIC right after stage 2 push. NIC names persisted to C:\Enrollment\disabled-wired-nics.txt for later re-enable. 2. Stages 3-6 status pushes fail silently while wired is down (PXE server lives on the air-gapped 10.9.100.0/24 LAN, unreachable from WiFi). Dashboard goes dark in that window. 3. PPKG installs, immediate reboot, AAD/Intune enroll over WiFi only. 4. IME boots, Report IP script fires with corp-WiFi IP only, writes C:\Logs\GE_Report_IP_Address*.txt. Webhook records clean IP. GE dynamic group eligibility flips. SFLD policy delivers next sync. 5. Monitor-IntuneProgress detects the log file, re-enables every NIC in the persisted list, sleeps 1s for link, then pushes idx=7 with DeviceId so the dashboard card flips to QR before the Intune- triggered LAPS-prompt reboot lands. Phase 1 remains "in progress" on the dashboard until Report IP fires - correct, the bay isn't actually registration-clean until then. Files: - Disable-WiredNics.ps1 (new) - persists names + disables - Run-ShopfloorSetup.ps1 - call after stage 2 Report-Stage - Monitor-IntuneProgress.ps1 - gate idx=7 push + re-enable Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
46 lines
2.0 KiB
PowerShell
46 lines
2.0 KiB
PowerShell
# Disable-WiredNics.ps1
|
|
# Disables every Up wired (MediaType 802.3) NIC and records their names to
|
|
# C:\Enrollment\disabled-wired-nics.txt so Monitor-IntuneProgress can
|
|
# re-enable them once Report IP has run on WiFi-only.
|
|
#
|
|
# Reason: GE's Intune Proactive-Remediation "Report IP" script enumerates
|
|
# Get-NetIPAddress and POSTs every IP it finds to a GE webhook. When a
|
|
# shopfloor bay is still cabled to the air-gapped PXE LAN (10.9.100.0/24),
|
|
# the webhook sees 10.9.100.x as one of the device's IPs and tags the bay
|
|
# "not on corp net". A dynamic group / assignment-filter at GE then excludes
|
|
# the bay from receiving the SFLD ConfigurationProfile (Function + SasToken
|
|
# OMA-URI) -> Phase 2 "Device Configuration" never closes.
|
|
#
|
|
# Killing the wired NIC after stage 2 reports + before AAD-join makes the
|
|
# bay's first Report IP fire see corp-WiFi IP only. The bay is tagged
|
|
# clean, dynamic group eligibility flips, SFLD policy delivers normally.
|
|
# Monitor-IntuneProgress re-enables the NIC once Report IP's log file
|
|
# appears at C:\Logs\GE_Report_IP_Address*.txt.
|
|
|
|
$ErrorActionPreference = 'Continue'
|
|
$stateFile = 'C:\Enrollment\disabled-wired-nics.txt'
|
|
|
|
try {
|
|
$wired = Get-NetAdapter -ErrorAction Stop |
|
|
Where-Object {
|
|
$_.Status -eq 'Up' -and
|
|
$_.MediaType -eq '802.3' -and
|
|
$_.HardwareInterface -eq $true
|
|
}
|
|
|
|
if (-not $wired) {
|
|
Write-Host "Disable-WiredNics: no Up wired NICs found - nothing to disable."
|
|
return
|
|
}
|
|
|
|
$names = $wired | ForEach-Object { $_.Name }
|
|
$names | Out-File -FilePath $stateFile -Encoding ASCII -Force
|
|
Write-Host ("Disable-WiredNics: persisted {0} NIC name(s) -> {1}" -f $names.Count, $stateFile)
|
|
foreach ($n in $names) { Write-Host " - $n" }
|
|
|
|
$wired | Disable-NetAdapter -Confirm:$false -ErrorAction Continue
|
|
Write-Host "Disable-WiredNics: NICs disabled. Re-enable triggered by Monitor when GE_Report_IP_Address log appears."
|
|
} catch {
|
|
Write-Warning "Disable-WiredNics: failed: $_"
|
|
}
|