Files
pxe-server/playbook/shopfloor-setup/Shopfloor/lib
cproudlock 7298d433eb 9999 machine-number prompt: split into user-context Prompt + SYSTEM-context Apply
OLD design: a single 'Check Machine Number' scheduled task ran as the
logged-in user (BUILTIN\Users, Limited) on AtLogOn. It both showed the
InputBox AND tried to update HKLM\SOFTWARE\WOW6432Node\GE Aircraft
Engines\DNC\General + C:\ProgramData\UDC\udc_settings.json. To make
those non-admin writes possible, 02-MachineNumberACLs.ps1 pre-granted
BUILTIN\Users SetValue + Modify on those targets during imaging.

Three problems with that:
  1. SECURITY: any logged-in user could overwrite the machine-identity
     reg key.
  2. FRAGILE: ACL grants raced with eDNC install timing on some bays
     (eDNC reg key didn't exist yet when 02-MachineNumberACLs ran;
     OpenSubKey returned null, ACL silently skipped, Check-MachineNumber
     later failed with PermissionDenied).
  3. SILENT-SUCCESS BUG: Update-MachineNumber's Set-ItemProperty calls
     lacked -ErrorAction Stop. PermissionDenied is a non-terminating
     error in PS5.1, so the try/catch never fired. The script set
     $out.EdncUpdated=$true anyway and the dialog reported success
     while the reg value stayed at 9999. WJF capture log on FGY07FZ3
     shows this exact pattern.

NEW design - two scheduled tasks split by responsibility:

  - "Prompt Machine Number" : AtLogOn trigger, BUILTIN\Users (Limited).
    Reads current values (read-only). If 9999, shows InputBox. Writes
    typed number to C:\Logs\SFLD\machine-number-request.txt. Triggers
    SYSTEM Apply via schtasks /run. Polls for result JSON (60s timeout).
    Shows result MessageBox with TopMost so it isn't hidden behind
    other windows.

  - "Apply Machine Number" : on-demand, SYSTEM (Highest). Reads the
    request file, calls Update-MachineNumber (full HKLM + ProgramData
    access from SYSTEM context). Pulls per-machine NTLARS .reg + UDC
    settings JSON + UDC live data from the SFLD share if site-config
    has share paths. Writes result JSON. Removes request file.
    Unregisters the Prompt task on full success (Prompt itself can't
    self-unregister - Limited users can't delete a SYSTEM-owned task).

  - Default task SDDL only allows Admins + SYSTEM to read/run a
    SYSTEM-owned task. Added BUILTIN\Users GR+GX ACE via COM
    SetSecurityDescriptor so the Limited Prompt task can schtasks /run
    Apply on demand. They can read + execute it; not modify or delete.

  - Update-MachineNumber.ps1 writes now have -ErrorAction Stop so
    PermissionDenied actually fires the catch block instead of being
    swallowed.

  - 02-MachineNumberACLs.ps1 gutted to a no-op (left in place for
    Stage-Dispatcher discovery; no longer grants the ACLs). Old bays'
    existing grants are harmless since SYSTEM ignores them.

  - Register-CheckMachineNumberTask.ps1 now installs both tasks AND
    unregisters the legacy 'Check Machine Number' task name on
    re-imaging. Run-ShopfloorSetup.ps1's $skipInBaseline list now
    includes Prompt-MachineNumber.ps1 + Apply-MachineNumber.ps1 so
    they aren't auto-run during the baseline pass (only via the
    scheduled tasks).

Smoke tested end-to-end on win11 VM with ShopFloor (Limited) logging in
interactively: AtLogOn trigger fired Prompt, dialog rendered, tech
typed 7777, schtasks /run succeeded (the SDDL fix lets Limited users
trigger SYSTEM tasks), Apply ran as SYSTEM, eDNC reg + machine-number.txt
both updated to 7777, result MessageBox shown, Prompt task auto-
unregistered by Apply's cleanup step. No ACL grants needed on any user.

Apply also re-tested with -ErrorAction Stop confirming non-terminating
PermissionDenied now properly throws into the catch + populates Errors[]
+ flips $out.EdncUpdated to false - so any future write failures will
report honestly instead of silently claiming success.
2026-05-24 17:08:59 -04:00
..