Files
pxe-server/playbook/shopfloor-setup/gea-shopfloor-collections
cproudlock 27045d5e4a gea-shopfloor-collections: controller NIC auto-IP + credential break-glass
04-SetControllerNicIP.ps1 (imaging-time, runs once via Run-ShopfloorSetup):
- Finds the Realtek physical Ethernet adapter (controller NIC on every
  collections bay; corp LAN is Intel)
- Skips any candidate with a DHCP default gateway (that one is the corp
  LAN, not the controller)
- Skips any candidate already on 192.168.1.2
- Sets static 192.168.1.2/24, no gateway, clears DNS - matches the
  manual procedure documented in post-deploy-debug-flowchart.md section 2B
- Refuses to guess when multiple Realtek NICs remain ambiguous
- Imaging-time only, not enforced via GE-Enforce so the tech can override
  on a specific bay if needed without the drift-catcher reverting

Set-ControllerCredential.ps1 + manifest-entry-controller-credential.json:
- Break-glass cmdkey /add for the controller SMB share (\\192.168.1.1\md1
  used by DNC). Scoped to the 12 Okuma LOC650 machine numbers (3201-3212).
- Manifest entry is detection-less so it runs every enforce cycle if the
  script is armed (.ps1 extension); disarmed by default (.ps1.bak on the
  share) so a coach can rename when a bay loses its credential without
  the enforcer overwriting per-bay deviations between events.
- Smoke-tested end-to-end on win11 VM via QGA: SYSTEM context cmdkey /add
  succeeds, cmdkey /list shows the entry. DNC service runs as LocalSystem
  so SYSTEM vault is the right target.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-21 19:38:59 -04:00
..