Three changes aimed at the same failure mode: a bay that images green and is silently unusable, diagnosed only by walking over and copying files off by hand. VERIFY STAGING (startnet, at :pctype_done) Checks pc-type.txt, Run-ShopfloorSetup.ps1, shopfloor-setup/common and shopfloor-setup/<PCTYPE> exist on the applied volume before anything depends on them, retries the small trees once, and prints a loud banner if the retry does not fix it. The enrollment package is checked but never blindly re-pulled - it is 8 GB, so a miss is reported instead. Done here because a tech is still at the machine: a short copy found in WinPE costs 30 seconds, the same copy found at first logon costs 20 minutes, and found never costs a rebuild. Four Display bays sat green at stage 2 for weeks. HARVEST LOGS (startnet, after PESetup exits) Collects X:\*.log, the generated X:\Unattend.xml, PESetup's own log from the target's Panther directory and winpe-staging.log into \<server>\enrollment\imaging-logs\<serial>\, plus a build-context.txt naming PCTYPE, PPKG, machine number and media. All of it was being discarded at reboot. Runs after PESetup exits so the logs are final, which means re-mapping Y: since cleanup already dropped it. Best-effort throughout - a bay must never fail to reboot because a log copy failed. W: WAIT CAP 20 -> 45 MINUTES 270 polls instead of 120. Fine on NVMe either way, but a WIM apply can exceed 20 minutes on slow media, and the failure mode is the os_not_found banner plus nothing staged. The loop still exits the moment the SYSTEM hive appears. RUN-ENROLLMENT RUNS ONCE Marker at C:\Enrollment\.ppkg-applied, written on exit 0 and also on 0x800700B7 ERROR_ALREADY_EXISTS. Observed running twice on 579C144; the second pass re-applied a pending rename over the package's own and otherwise did nothing. Verified: startnet parens balance, every goto resolves, 899 CRLF lines with no bare LF; run-enrollment parses clean under the PowerShell parser. Deployed - boot.wim md5 159c2a4d, live run-enrollment dce9d50a.
900 lines
43 KiB
Batchfile
900 lines
43 KiB
Batchfile
@echo off
|
|
echo Please wait while 'WinPE' is being processed. This may take a few seconds.
|
|
wpeinit
|
|
powercfg /s 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c
|
|
|
|
REM --- Wait for network (DHCP may take a moment after wpeinit) ---
|
|
echo Waiting for network...
|
|
:wait_net
|
|
ping -n 2 172.16.9.1 >NUL 2>&1
|
|
if errorlevel 1 goto wait_net
|
|
echo Network ready.
|
|
|
|
REM --- BIOS update check (runs before imaging menu) ---
|
|
REM Mounts [winpeapps_bios] share. CRITICAL: do NOT call check-bios.cmd
|
|
REM inside an `if exist (...)` parens block - CMD's variable scoping for
|
|
REM CALLed scripts inside parens does not propagate BIOS_STATUS back to
|
|
REM this script reliably. Use goto-flow instead so the CALL runs at the
|
|
REM top scope and BIOS_STATUS persists.
|
|
set BIOS_STATUS=No BIOS check (share unavailable)
|
|
net use B: \\172.16.9.1\winpeapps_bios /user:pxe-upload pxe /persistent:no 2>NUL
|
|
if not exist B:\check-bios.cmd goto :bios_check_done
|
|
echo.
|
|
echo Checking for BIOS updates...
|
|
call B:\check-bios.cmd
|
|
:bios_check_done
|
|
net use B: /delete 2>NUL
|
|
|
|
:menu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo WinPE Setup Menu
|
|
echo ========================================
|
|
echo Firmware: %BIOS_STATUS%
|
|
echo.
|
|
echo Please select an option:
|
|
echo.
|
|
echo 1. GEA Standard
|
|
echo 2. GEA Engineer
|
|
echo 3. GEA Shopfloor (sub-menu)
|
|
echo.
|
|
echo ========================================
|
|
echo.
|
|
set /p choice=Enter your choice (1-3):
|
|
|
|
REM --- Shopfloor images (3,6,7) need GCCH enrollment + (for 3) PC-type sub-menu.
|
|
REM Choice 3 = GEA Shopfloor: drill into sub-menu first to pick the gea-shopfloor-*
|
|
REM sub-category, THEN the office menu, THEN machine number for collections+nocollections.
|
|
set PPKG=
|
|
if "%choice%"=="3" goto gea_shopfloor_submenu
|
|
if "%choice%"=="6" goto enroll_menu
|
|
if "%choice%"=="7" goto enroll_menu
|
|
goto enroll_staged
|
|
|
|
:gea_shopfloor_submenu
|
|
cls
|
|
set PCTYPE=
|
|
REM Data-driven PC-type menu: the PXE webapp maintains menu.json on the
|
|
REM enrollment share; select-shopfloor-type.ps1 renders it and writes the
|
|
REM chosen PCTYPE to X:\pctype.txt. Falls back to the baked-in menu below if
|
|
REM the share or the picker is unavailable (mirrors the CMM bay picker).
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no >NUL 2>NUL
|
|
del X:\pctype.txt 2>NUL
|
|
if exist "Y:\shopfloor-setup\select-shopfloor-type.ps1" powershell.exe -NoProfile -ExecutionPolicy Bypass -File "Y:\shopfloor-setup\select-shopfloor-type.ps1" -MenuJson "Y:\shopfloor-setup\menu.json" -OutFile "X:\pctype.txt"
|
|
if exist X:\pctype.txt set /p PCTYPE=<X:\pctype.txt
|
|
if not "%PCTYPE%"=="" goto gea_shopfloor_have_type
|
|
|
|
:gea_shopfloor_submenu_fallback
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo GEA Shopfloor PC Sub-Type
|
|
echo ========================================
|
|
echo.
|
|
echo 1. Machine with Collections (eDNC + UDC + Plant Apps)
|
|
echo 2. Machine without Collections (eDNC + Plant Apps, no UDC)
|
|
echo 3. Common (Timeclock, Lab; WJ Shopfloor only)
|
|
echo 4. Keyence (VR-3000 / VR-5000 / VR-6000 microscope)
|
|
echo 5. CMM (Hexagon PC-DMIS + Protect Viewer)
|
|
echo 6. Genspect
|
|
echo 7. Heattreat (eDNC + HeatTreat app)
|
|
echo 8. Wax and Trace
|
|
echo 9. Display (kiosk dashboard)
|
|
echo 10. Part Marker (eDNC + Telesis Mark)
|
|
echo.
|
|
set /p ges_choice=Enter your choice (1-10):
|
|
if "%ges_choice%"=="1" set PCTYPE=gea-shopfloor-collections
|
|
if "%ges_choice%"=="2" set PCTYPE=gea-shopfloor-nocollections
|
|
if "%ges_choice%"=="3" set PCTYPE=gea-shopfloor-common
|
|
if "%ges_choice%"=="4" set PCTYPE=gea-shopfloor-keyence
|
|
if "%ges_choice%"=="5" set PCTYPE=gea-shopfloor-cmm
|
|
if "%ges_choice%"=="6" set PCTYPE=gea-shopfloor-genspect
|
|
if "%ges_choice%"=="7" set PCTYPE=gea-shopfloor-heattreat
|
|
if "%ges_choice%"=="8" set PCTYPE=gea-shopfloor-waxtrace
|
|
if "%ges_choice%"=="9" set PCTYPE=gea-shopfloor-display
|
|
if "%ges_choice%"=="10" set PCTYPE=gea-shopfloor-partmarker
|
|
if "%PCTYPE%"=="" goto gea_shopfloor_submenu_fallback
|
|
|
|
:gea_shopfloor_have_type
|
|
if "%PCTYPE%"=="gea-shopfloor-display" goto display_submenu
|
|
if "%PCTYPE%"=="gea-shopfloor-keyence" goto keyence_submenu
|
|
if "%PCTYPE%"=="gea-shopfloor-cmm" goto cmm_submenu
|
|
goto enroll_menu
|
|
|
|
:keyence_submenu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo Keyence Model
|
|
echo ========================================
|
|
echo.
|
|
echo 1. VR-3000 G2 (older microscope/profilometer line)
|
|
echo 2. VR-5000 (mid-range)
|
|
echo 3. VR-6000 (current line)
|
|
echo.
|
|
set KEYENCEMODEL=
|
|
set /p kmod_choice=Enter your choice (1-3):
|
|
if "%kmod_choice%"=="1" set KEYENCEMODEL=vr3000
|
|
if "%kmod_choice%"=="2" set KEYENCEMODEL=vr5000
|
|
if "%kmod_choice%"=="3" set KEYENCEMODEL=vr6000
|
|
if "%KEYENCEMODEL%"=="" goto keyence_submenu
|
|
echo Keyence model: %KEYENCEMODEL%
|
|
goto enroll_menu
|
|
|
|
:cmm_submenu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo CMM Bay Selection
|
|
echo ========================================
|
|
echo.
|
|
echo Loading CMM bay list from PXE share...
|
|
REM Mount enrollment share early so the picker can read the CSV.
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no >NUL 2>NUL
|
|
del X:\cmm-bay.txt 2>NUL
|
|
set CMMID=
|
|
set CMMVARIANT=standard
|
|
if not exist "Y:\installers-post\cmm\select-cmm-bay.ps1" goto cmm_picker_skip
|
|
powershell.exe -NoProfile -ExecutionPolicy Bypass -File "Y:\installers-post\cmm\select-cmm-bay.ps1" -ConfigPath "Y:\installers-post\cmm\cmm-bay-config.csv" -OutFile "X:\cmm-bay.txt"
|
|
:cmm_picker_skip
|
|
if exist X:\cmm-bay.txt set /p CMMID=<X:\cmm-bay.txt
|
|
if not "%CMMID%"=="" goto cmm_have_bay
|
|
echo.
|
|
echo Picker unavailable or cancelled. Falling back to manual entry.
|
|
set /p CMMID=Enter CMM ID (e.g. CMM1):
|
|
:cmm_have_bay
|
|
if "%CMMID%"=="" (
|
|
echo WARNING: no CMM ID entered. Defaulting to standard variant.
|
|
goto enroll_menu
|
|
)
|
|
echo CMM bay: %CMMID%
|
|
REM Resolve bay config (writes version.txt + doda.txt to %OSDRIVE%\Enrollment\cmm\
|
|
REM after %OSDRIVE% appears). Resolution deferred to after imaging starts - store
|
|
REM the CMMID for now and resolve in the post-imaging copy block below.
|
|
goto enroll_menu
|
|
|
|
:display_submenu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo Display Kiosk Sub-Type
|
|
echo ========================================
|
|
echo.
|
|
echo 1. Dashboard (shop floor metrics dashboard)
|
|
echo 2. Lobby Display (lobby information screen)
|
|
echo.
|
|
set DISPLAYTYPE=
|
|
set /p disp_choice=Enter your choice (1-2):
|
|
if "%disp_choice%"=="1" set DISPLAYTYPE=Dashboard
|
|
if "%disp_choice%"=="2" set DISPLAYTYPE=Lobby
|
|
if "%DISPLAYTYPE%"=="" goto display_submenu
|
|
goto enroll_menu
|
|
|
|
:enroll_menu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo GCCH Enrollment Profile
|
|
echo ========================================
|
|
echo.
|
|
echo 1. No Office
|
|
echo 2. Standard Office (x86)
|
|
echo 3. Standard Office (x64)
|
|
echo 4. Pro Plus Office (x86) with Access
|
|
echo 5. Pro Plus Office (x64) with Access
|
|
echo 6. Skip enrollment
|
|
echo.
|
|
set /p enroll=Enter your choice (1-6):
|
|
|
|
REM --- PPKG configuration (constructed at menu time, see docs) ---
|
|
REM Vendor ships one source PPKG; we construct the BPRT-tagged filename
|
|
REM by filling in Office, Region, Expiry, Version on the target copy.
|
|
REM The ACTIVE ppkg is read from \\172.16.9.1\enrollment\ppkg.conf, which the
|
|
REM PXE webapp writes on upload - so a new ppkg goes live with no startnet edit.
|
|
REM The baked-in values below are only a fallback if ppkg.conf is missing.
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no >nul 2>&1
|
|
set SOURCE_PPKG=
|
|
set TARGET_PPKG=
|
|
set PPKG_VER=
|
|
set PPKG_EXP=
|
|
if exist "Y:\ppkg.conf" (
|
|
for /f "usebackq tokens=1,* delims==" %%A in ("Y:\ppkg.conf") do (
|
|
if /i "%%A"=="SOURCE_PPKG" set "SOURCE_PPKG=%%B"
|
|
if /i "%%A"=="PPKG_VER" set "PPKG_VER=%%B"
|
|
if /i "%%A"=="PPKG_EXP" set "PPKG_EXP=%%B"
|
|
if /i "%%A"=="TARGET_PPKG" set "TARGET_PPKG=%%B"
|
|
)
|
|
)
|
|
if "%SOURCE_PPKG%"=="" set SOURCE_PPKG=GCCH_Prod_SFLD_v4.16.ppkg
|
|
if "%PPKG_VER%"=="" set PPKG_VER=v4.16
|
|
if "%PPKG_EXP%"=="" set PPKG_EXP=20260831
|
|
set REGION=US
|
|
|
|
set OFFICE=
|
|
if "%enroll%"=="1" set OFFICE=NoOffice
|
|
if "%enroll%"=="2" set OFFICE=StdOffice-x86
|
|
if "%enroll%"=="3" set OFFICE=StdOffice-x64
|
|
if "%enroll%"=="4" set OFFICE=ProPlusOffice-x86
|
|
if "%enroll%"=="5" set OFFICE=ProPlusOffice-x64
|
|
if "%enroll%"=="6" set OFFICE=
|
|
if "%enroll%"=="" goto enroll_menu
|
|
|
|
set PPKG=
|
|
REM Target filename for the staged package.
|
|
REM
|
|
REM The SFLD-era scheme encoded an Office variant in the name
|
|
REM (GCCH_Prod_SFLD_<Office>_<Region>_Exp_<date>_<ver>.ppkg) because one source
|
|
REM package was renamed per Office choice. MCL packages do not work that way -
|
|
REM Office is installed by Install-Office.ps1 inside the package - and renaming
|
|
REM an MCL package into the SFLD scheme just produces a misleading filename.
|
|
REM
|
|
REM So: honour TARGET_PPKG from ppkg.conf when present, otherwise keep the
|
|
REM source filename unchanged. The SFLD construction remains only as a fallback
|
|
REM for a legacy SFLD source package.
|
|
if not "%TARGET_PPKG%"=="" (
|
|
set PPKG=%TARGET_PPKG%
|
|
) else (
|
|
REM find, NOT findstr: findstr.exe is not in this WinPE image (find.exe is,
|
|
REM and startnet already uses it for the PESetup wait). findstr fails with
|
|
REM "not recognized", leaves errorlevel 9009, and "if errorlevel 1" then
|
|
REM takes the NON-SFLD branch for an SFLD package - so the staged ppkg keeps
|
|
REM its source name and never gets the BPRT-tagged one.
|
|
echo %SOURCE_PPKG% | find /I "_SFLD_" >NUL
|
|
if errorlevel 1 (
|
|
set PPKG=%SOURCE_PPKG%
|
|
) else (
|
|
if not "%OFFICE%"=="" set PPKG=GCCH_Prod_SFLD_%OFFICE%_%REGION%_Exp_%PPKG_EXP%_%PPKG_VER%.ppkg
|
|
)
|
|
)
|
|
|
|
REM --- 2026-05-04 rename reorg: PCTYPE is set by gea_shopfloor_submenu above
|
|
REM (single string, e.g. gea-shopfloor-collections). pc-subtype.txt is no
|
|
REM longer written. DISPLAYTYPE IS still written (display-type.txt) when
|
|
REM PCTYPE=gea-shopfloor-display because Install-KioskApp.cmd needs Lobby
|
|
REM vs Dashboard to choose installer + Get-PCProfile builds Display-{type}
|
|
REM profile key.
|
|
set PCSUBTYPE=
|
|
|
|
REM --- Machine number / asset tag (only PC types that key per-machine config) ---
|
|
REM collections + nocollections = 4-digit machine number for shopfloor identification.
|
|
REM waxtrace = asset tag like WJRP2335 used to match per-machine cal ISO during
|
|
REM 09-Setup-WaxAndTrace.ps1. Cal ISO files are named
|
|
REM CAL-{asset_tag}_serial-*_probe-*.iso.
|
|
set MACHINENUM=9999
|
|
if /i "%PCTYPE%"=="gea-shopfloor-collections" goto prompt_machinenum
|
|
if /i "%PCTYPE%"=="gea-shopfloor-nocollections" goto prompt_machinenum
|
|
if /i "%PCTYPE%"=="gea-shopfloor-heattreat" goto prompt_machinenum
|
|
if /i "%PCTYPE%"=="gea-shopfloor-waxtrace" goto prompt_waxtrace_asset
|
|
if /i "%PCTYPE%"=="gea-shopfloor-cmm" goto skip_machinenum
|
|
goto skip_machinenum
|
|
:prompt_machinenum
|
|
echo.
|
|
set /p MACHINENUM=Enter machine number (digits, or Enter for 9999):
|
|
if "%MACHINENUM%"=="" set MACHINENUM=9999
|
|
echo Machine number: %MACHINENUM%
|
|
goto skip_machinenum
|
|
:prompt_waxtrace_asset
|
|
echo.
|
|
echo Loading Wax/Trace bay list from PXE share...
|
|
REM Mount enrollment share early so the picker can read INDEX.csv. Later
|
|
REM net use Y: will be a no-op if Y: is already mapped.
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no >NUL 2>NUL
|
|
del X:\waxtrace-asset.txt 2>NUL
|
|
if not exist "Y:\installers-post\waxtrace\select-waxtrace-asset.ps1" goto waxtrace_picker_skip
|
|
powershell.exe -NoProfile -ExecutionPolicy Bypass -File "Y:\installers-post\waxtrace\select-waxtrace-asset.ps1" -IndexPath "Y:\installers-post\waxtrace\bay-config.csv" -OutFile "X:\waxtrace-asset.txt"
|
|
:waxtrace_picker_skip
|
|
set MACHINENUM=
|
|
if exist X:\waxtrace-asset.txt set /p MACHINENUM=<X:\waxtrace-asset.txt
|
|
if not "%MACHINENUM%"=="" goto waxtrace_have_asset
|
|
echo.
|
|
echo Picker unavailable or cancelled. Falling back to free-text prompt.
|
|
echo Wax/Trace bays use the asset tag, e.g. WJRP2335 or WJF00159, to pick
|
|
echo the right calibration ISO during shopfloor setup.
|
|
set /p MACHINENUM=Enter asset tag:
|
|
:waxtrace_have_asset
|
|
if "%MACHINENUM%"=="" echo WARNING: no asset tag entered - calibration apply will be skipped.
|
|
echo Asset tag: %MACHINENUM%
|
|
:skip_machinenum
|
|
|
|
REM --- Map enrollment share early (kept open for copy after imaging) ---
|
|
REM Y: may already be mapped from :prompt_waxtrace_asset (picker block).
|
|
REM net use of an already-mapped letter throws "System error 85: The local
|
|
REM device name is already in use" which is harmless but noisy on screen.
|
|
REM Skip the re-map when Y: is already mounted.
|
|
set NEED_ENROLL=0
|
|
if not "%PPKG%"=="" set NEED_ENROLL=1
|
|
if not "%PCTYPE%"=="" set NEED_ENROLL=1
|
|
if "%NEED_ENROLL%"=="0" goto enroll_staged
|
|
if exist Y:\ goto enroll_already_mapped
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no
|
|
:enroll_already_mapped
|
|
if "%PPKG%"=="" goto enroll_staged
|
|
if not exist "Y:\ppkgs\%SOURCE_PPKG%" (
|
|
echo WARNING: %SOURCE_PPKG% not found on server. Enrollment will be skipped.
|
|
set PPKG=
|
|
)
|
|
:enroll_staged
|
|
|
|
echo. > X:\Boot.tag
|
|
if "%choice%"=="1" goto gea-standard
|
|
if "%choice%"=="2" goto gea-engineer
|
|
if "%choice%"=="3" goto gea-shopfloor
|
|
echo Invalid choice. Please try again.
|
|
pause
|
|
goto menu
|
|
|
|
:gea-standard
|
|
echo.
|
|
echo Starting GEA Standard setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\gea-standard /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:gea-engineer
|
|
echo.
|
|
echo Starting GEA Engineer setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\gea-engineer /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:gea-shopfloor
|
|
echo.
|
|
echo Starting GEA Shopfloor setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
REM --- Per-PCTYPE media view -----------------------------------------------
|
|
REM PESetup's CopyPackages copies the WHOLE of <media>\Deploy\Applications to
|
|
REM the target, recursively, with no filtering and no manifest (see
|
|
REM docs/PESETUP-INTERNALS.md). One shared shopfloor media therefore hands
|
|
REM every shopfloor payload to every bay whatever its type.
|
|
REM _media\<PCTYPE> is that same media rebuilt out of symlinks by
|
|
REM scripts/build-pctype-media.py, carrying only this type's payload. It is
|
|
REM built once, server-side, and never mutated per session: bays image
|
|
REM concurrently and CopyPackages is fail-fast, so changing a path mid-copy
|
|
REM would fail some OTHER bay's imaging.
|
|
if "%PCTYPE%"=="" goto gea_shopfloor_media_shared
|
|
REM Free Z: first. A leftover mapping makes net use fail with "device already
|
|
REM in use" and the probe below would then pass against the OLD media.
|
|
net use Z: /delete /y >NUL 2>&1
|
|
net use Z: \\172.16.9.1\winpeapps\_media\%PCTYPE% /user:pxe-upload pxe /persistent:no >NUL 2>&1
|
|
REM Probe a file that only resolves when the view exists AND its symlinks are
|
|
REM intact. A dangling view must not image silently off a half-mapped drive.
|
|
if exist "Z:\Deploy\Control\HardwareDriver.json" goto end
|
|
echo.
|
|
echo WARNING: no usable per-type media at _media\%PCTYPE%.
|
|
echo Falling back to the shared shopfloor media, so EVERY shopfloor
|
|
echo payload will be staged on this bay, not just this type's.
|
|
echo Imaging is otherwise unaffected. Tell the PXE admin.
|
|
echo.
|
|
net use Z: /delete /y >NUL 2>&1
|
|
|
|
:gea_shopfloor_media_shared
|
|
net use Z: \\172.16.9.1\winpeapps\gea-shopfloor /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:end
|
|
echo.
|
|
|
|
REM --- Push initial "WinPE staging" status to PXE webapp ---
|
|
REM Externalized to Y:\scripts\winpe-status-push.ps1 so future edits don't
|
|
REM require a boot.wim rebuild. Best-effort; the script logs to
|
|
REM X:\Windows\Temp\winpe-status-push.log and swallows all errors.
|
|
if exist "Y:\scripts\winpe-status-push.ps1" (
|
|
powershell -NoProfile -ExecutionPolicy Bypass -File "Y:\scripts\winpe-status-push.ps1"
|
|
)
|
|
|
|
echo Waiting for PESetup.exe to start...
|
|
:wait_start
|
|
ping -n 3 127.0.0.1 >NUL
|
|
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
|
|
if errorlevel 1 goto wait_start
|
|
echo PESetup.exe is running. Waiting for imaging to complete...
|
|
|
|
REM --- Copy enrollment package and shopfloor setup as soon as Windows partition appears ---
|
|
if "%PPKG%"=="" if "%PCTYPE%"=="" goto wait_finish
|
|
REM --- Wait for the volume PESetup applies Windows to -----------------------
|
|
REM PESetup hardcodes W: in nine places - every copy destination, both DISM
|
|
REM offline sessions, bcdboot and reagentc - and CREATES it during its own disk
|
|
REM preparation. See docs/PESETUP-INTERNALS.md. There is nothing to search for.
|
|
REM
|
|
REM Do NOT try to locate the volume earlier by scanning for a Windows install.
|
|
REM Proven on 579C144, 2026-08-06, PESetup 4.0.0.20:
|
|
REM 11:30:07 PESetup logs the OLD install still mounted at C:
|
|
REM 11:30:18 operator presses Next
|
|
REM 11:30:20 PESetup runs DISKPART /S X:\diskpartEFI0.txt - the wipe
|
|
REM 11:30:24 a volume scan had returned that C:, startnet assigned it W: and
|
|
REM staged into the partition PESetup was mid-way through erasing.
|
|
REM Every robocopy died, "The system cannot find the path
|
|
REM specified", and NOTHING was staged.
|
|
REM 11:30:30 PESetup creates its own W: and starts copying to it
|
|
REM The SYSTEM hive is the signal that distinguishes the applied image from the
|
|
REM one being wiped: it exists only once the WIM apply has written it. Do not
|
|
REM weaken this test to "the volume exists" or "Windows is present".
|
|
set OSDRIVE=
|
|
echo Waiting for the applied Windows volume at W: ...
|
|
set OSWAIT=0
|
|
:wait_enroll
|
|
if exist W:\Windows\System32\config\system (
|
|
set OSDRIVE=W:
|
|
goto found_os
|
|
)
|
|
set /a OSWAIT+=1
|
|
REM 270 polls at ~10s = 45 minutes. Was 120 (20 min), which is fine on NVMe but
|
|
REM tight on slow media - a WIM apply can run 25+ minutes there, and the failure
|
|
REM mode is the scary os_not_found banner plus nothing staged. Waiting longer
|
|
REM costs nothing: the loop exits the moment the SYSTEM hive appears.
|
|
if %OSWAIT% GEQ 270 goto os_not_found
|
|
ping -n 11 127.0.0.1 >NUL
|
|
goto wait_enroll
|
|
|
|
:os_not_found
|
|
echo.
|
|
echo ******************************************************************
|
|
echo ERROR: no applied Windows volume found.
|
|
echo NOTHING was staged: pc-type.txt, the enrollment package and
|
|
echo shopfloor-setup are all missing. Imaging will finish but the
|
|
echo post-install setup will NOT run. Tell the PXE admin.
|
|
echo ******************************************************************
|
|
echo.
|
|
goto cleanup_enroll
|
|
|
|
:found_os
|
|
echo Found Windows at %OSDRIVE%
|
|
|
|
REM No drive-letter reassignment here. PESetup owns W: and runs its own DISKPART
|
|
REM against the same disk; a second diskpart racing it destroys the volume that
|
|
REM staging is writing to. The unattend's hardcoded W:\Drivers path is PESetup's
|
|
REM own destination (CopyDrivers unzips there), so it lines up by construction.
|
|
mkdir %OSDRIVE%\Enrollment 2>NUL
|
|
REM Log all copy operations to a file that persists on the target disk.
|
|
REM Tech can check C:\Enrollment\winpe-staging.log post-imaging.
|
|
REM Each echo in the copy block below also appends to this file via
|
|
REM the >> redirect after the screen echo. robocopy /LOG+ appends its
|
|
REM own output directly.
|
|
set STAGELOG=%OSDRIVE%\Enrollment\winpe-staging.log
|
|
echo [%DATE% %TIME%] WinPE staging started >> "%STAGELOG%"
|
|
echo PCTYPE=%PCTYPE% PPKG=%PPKG% MACHINENUM=%MACHINENUM% CMMID=%CMMID% >> "%STAGELOG%"
|
|
|
|
REM --- Copy site config (drives site-specific values in all setup scripts) ---
|
|
if exist "Y:\config\site-config.json" (
|
|
robocopy "Y:\config" "%OSDRIVE%\Enrollment" "site-config.json" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
if errorlevel 8 (
|
|
echo WARNING: site-config.json robocopy FAILED - not staged.
|
|
echo [%TIME%] FAILED: site-config.json robocopy >> "%STAGELOG%"
|
|
) else (
|
|
echo Copied site-config.json.
|
|
echo [%TIME%] Copied site-config.json >> "%STAGELOG%"
|
|
)
|
|
) else (
|
|
echo WARNING: site-config.json not found on enrollment share.
|
|
echo [%TIME%] WARNING: site-config.json not found >> "%STAGELOG%"
|
|
)
|
|
|
|
REM --- Copy PPKG if selected (renames from SOURCE to BPRT-tagged filename) ---
|
|
if "%PPKG%"=="" goto copy_pctype
|
|
robocopy "Y:\ppkgs" "%OSDRIVE%\Enrollment" "%SOURCE_PPKG%" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
REM robocopy exit codes: 0-7 = success, 8+ = failure (inverse of copy's 0/1).
|
|
if errorlevel 8 (
|
|
echo WARNING: Failed to copy enrollment package.
|
|
echo [%TIME%] WARNING: Failed to copy PPKG %SOURCE_PPKG% >> "%STAGELOG%"
|
|
goto copy_pctype
|
|
)
|
|
REM robocopy keeps the source name; rename to the BPRT-tagged target name.
|
|
if not "%SOURCE_PPKG%"=="%PPKG%" ren "%OSDRIVE%\Enrollment\%SOURCE_PPKG%" "%PPKG%"
|
|
echo [%TIME%] Copied PPKG %SOURCE_PPKG% as %PPKG% >> "%STAGELOG%"
|
|
robocopy "Y:\scripts" "%OSDRIVE%\Enrollment" "run-enrollment.ps1" "wait-for-internet.ps1" "migrate-to-wifi.ps1" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
echo [%TIME%] Copied enrollment scripts >> "%STAGELOG%"
|
|
|
|
REM --- Create enroll.cmd at drive root as manual fallback ---
|
|
> %OSDRIVE%\enroll.cmd (
|
|
echo @echo off
|
|
echo echo Waiting for network...
|
|
echo :waitnet
|
|
echo ping -n 2 8.8.8.8 ^>NUL 2^>^&1
|
|
echo if errorlevel 1 goto waitnet
|
|
echo echo Network connected. Running enrollment...
|
|
echo powershell.exe -ExecutionPolicy Bypass -File "C:\Enrollment\run-enrollment.ps1"
|
|
)
|
|
echo Manual fallback created at %OSDRIVE%\enroll.cmd
|
|
|
|
:copy_pctype
|
|
REM --- Copy shopfloor PC type setup scripts ---
|
|
if "%PCTYPE%"=="" goto cleanup_enroll
|
|
echo %PCTYPE%> %OSDRIVE%\Enrollment\pc-type.txt
|
|
REM 2026-05-04 rename reorg: pc-subtype.txt no longer written.
|
|
REM display-type.txt IS still written for gea-shopfloor-display because
|
|
REM Install-KioskApp.cmd reads it to pick Lobby vs Dashboard installer
|
|
REM and Get-PCProfile.ps1 reads it to build the Display-{type} profile key.
|
|
if not "%DISPLAYTYPE%"=="" echo %DISPLAYTYPE%> %OSDRIVE%\Enrollment\display-type.txt
|
|
if not "%MACHINENUM%"=="" echo %MACHINENUM%> %OSDRIVE%\Enrollment\machine-number.txt
|
|
REM Keyence model goes to BOTH keyence-model.txt (read by 09-Setup-Keyence) AND
|
|
REM pc-subtype.txt (read by GE-Enforce for per-model dispatch via existing
|
|
REM PCSubType wiring: looks for gea-shopfloor-keyence-<model>\manifest.json on share).
|
|
if not "%KEYENCEMODEL%"=="" (
|
|
echo %KEYENCEMODEL%> %OSDRIVE%\Enrollment\keyence-model.txt
|
|
echo %KEYENCEMODEL%> %OSDRIVE%\Enrollment\pc-subtype.txt
|
|
)
|
|
REM CMM bay ID + resolved config. CMMID comes from the bay picker (e.g. CMM4).
|
|
REM Written to machine-number.txt (same field collections/waxtrace use) so
|
|
REM TargetMachineNumbers on the SFLD share manifest gates per-bay entries.
|
|
REM resolve-cmm-bay-config.ps1 reads the CSV and writes version.txt + doda.txt
|
|
REM to %OSDRIVE%\Enrollment\cmm\ for 09-Setup-CMM.ps1 to consume.
|
|
if "%CMMID%"=="" goto cmm_id_done
|
|
echo %CMMID%> %OSDRIVE%\Enrollment\machine-number.txt
|
|
mkdir %OSDRIVE%\Enrollment\cmm 2>NUL
|
|
if exist "Y:\installers-post\cmm\resolve-cmm-bay-config.ps1" (
|
|
powershell.exe -NoProfile -ExecutionPolicy Bypass -File "Y:\installers-post\cmm\resolve-cmm-bay-config.ps1" -ConfigPath "Y:\installers-post\cmm\cmm-bay-config.csv" -CmmId "%CMMID%" -OutDir "%OSDRIVE%\Enrollment\cmm"
|
|
)
|
|
REM Read doda flag to set pc-subtype.txt for GE-Enforce manifest gating.
|
|
REM goto-flow avoids CMD variable scoping issues inside parens blocks.
|
|
if not exist %OSDRIVE%\Enrollment\cmm\doda.txt goto cmm_id_done
|
|
set /p CMMDODA=<%OSDRIVE%\Enrollment\cmm\doda.txt
|
|
if /i "%CMMDODA%"=="yes" echo doda> %OSDRIVE%\Enrollment\pc-subtype.txt
|
|
:cmm_id_done
|
|
robocopy "Y:\shopfloor-setup" "%OSDRIVE%\Enrollment" "Run-ShopfloorSetup.ps1" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
REM Post-boot bulk re-fetch. WinPE staging below is best-effort (it can fail if
|
|
REM the Y: mount went idle-dead during the WIM apply); Fetch-StagingPayload.ps1
|
|
REM re-pulls the shopfloor-setup tree + preinstall bundle at first logon on a
|
|
REM FRESH mount. The unattend FirstLogonCommands runs it before the PowerShell 7
|
|
REM MSI + Run-ShopfloorSetup. Stage the script + its source coords here.
|
|
robocopy "Y:\shopfloor-setup" "%OSDRIVE%\Enrollment" "Fetch-StagingPayload.ps1" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
REM Stage the staging self-heal directly too, so the unattend Order 5 heal step
|
|
REM runs even if Fetch-StagingPayload itself did not land. Small, reliable copy.
|
|
robocopy "Y:\shopfloor-setup" "%OSDRIVE%\Enrollment" "Verify-And-Heal-Staging.ps1" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
> %OSDRIVE%\Enrollment\fetch-source.txt (
|
|
echo \\172.16.9.1\enrollment
|
|
echo pxe-upload
|
|
echo pxe
|
|
)
|
|
REM --- Always copy Shopfloor baseline scripts ---
|
|
mkdir %OSDRIVE%\Enrollment\shopfloor-setup 2>NUL
|
|
robocopy "Y:\shopfloor-setup" "%OSDRIVE%\Enrollment\shopfloor-setup" "backup_lockdown.bat" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
if exist "Y:\shopfloor-setup\Shopfloor" (
|
|
mkdir %OSDRIVE%\Enrollment\shopfloor-setup\Shopfloor 2>NUL
|
|
robocopy "Y:\shopfloor-setup\Shopfloor" "%OSDRIVE%\Enrollment\shopfloor-setup\Shopfloor" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
REM Report what actually happened. These echoes used to run unconditionally
|
|
REM and printed "Copied ..." for six copies that moved zero bytes.
|
|
REM %ERRORLEVEL% is not printed: inside a parenthesised block it expands at
|
|
REM PARSE time, so it shows a stale value from before the robocopy ran.
|
|
if errorlevel 8 (
|
|
echo WARNING: shopfloor-setup\Shopfloor robocopy FAILED - nothing copied.
|
|
echo [%TIME%] FAILED: Shopfloor baseline robocopy >> "%STAGELOG%"
|
|
) else (
|
|
echo Copied Shopfloor baseline setup files.
|
|
echo [%TIME%] Copied Shopfloor baseline >> "%STAGELOG%"
|
|
)
|
|
)
|
|
REM --- Always copy common/ (cross-PC-type GE-Enforce dispatcher + lib live here post-v2) ---
|
|
if exist "Y:\shopfloor-setup\common" (
|
|
mkdir %OSDRIVE%\Enrollment\shopfloor-setup\common 2>NUL
|
|
robocopy "Y:\shopfloor-setup\common" "%OSDRIVE%\Enrollment\shopfloor-setup\common" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: shopfloor-setup\common robocopy FAILED - nothing copied.
|
|
echo [%TIME%] FAILED: common robocopy >> "%STAGELOG%"
|
|
) else (
|
|
echo Copied common setup files.
|
|
echo [%TIME%] Copied common >> "%STAGELOG%"
|
|
)
|
|
)
|
|
REM --- Copy _ntlars-backups (147 per-bay .reg files restored by gea-shopfloor-{collections,nocollections}\03-RestoreEDncConfig.ps1) ---
|
|
REM Same root level as common/, referenced by 03-RestoreEDncConfig.ps1 via Join-Path $PSScriptRoot '..\_ntlars-backups'.
|
|
if exist "Y:\shopfloor-setup\_ntlars-backups" (
|
|
mkdir %OSDRIVE%\Enrollment\shopfloor-setup\_ntlars-backups 2>NUL
|
|
robocopy "Y:\shopfloor-setup\_ntlars-backups" "%OSDRIVE%\Enrollment\shopfloor-setup\_ntlars-backups" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: _ntlars-backups robocopy FAILED - nothing copied.
|
|
echo [%TIME%] FAILED: _ntlars-backups robocopy >> "%STAGELOG%"
|
|
) else (
|
|
echo Copied _ntlars-backups.
|
|
echo [%TIME%] Copied _ntlars-backups >> "%STAGELOG%"
|
|
)
|
|
)
|
|
REM --- Copy type-specific scripts on top of baseline ---
|
|
if exist "Y:\shopfloor-setup\%PCTYPE%" (
|
|
mkdir "%OSDRIVE%\Enrollment\shopfloor-setup\%PCTYPE%" 2>NUL
|
|
robocopy "Y:\shopfloor-setup\%PCTYPE%" "%OSDRIVE%\Enrollment\shopfloor-setup\%PCTYPE%" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: shopfloor-setup\%PCTYPE% robocopy FAILED - nothing copied.
|
|
echo [%TIME%] FAILED: %PCTYPE% type-specific robocopy >> "%STAGELOG%"
|
|
) else (
|
|
echo Copied %PCTYPE% setup files.
|
|
echo [%TIME%] Copied %PCTYPE% type-specific >> "%STAGELOG%"
|
|
)
|
|
) else (
|
|
echo WARNING: No setup files found for PC type %PCTYPE%.
|
|
echo [%TIME%] WARNING: No setup files for %PCTYPE% >> "%STAGELOG%"
|
|
)
|
|
|
|
REM --- Stage preinstall bundle (apps installed locally to save Azure bandwidth) ---
|
|
if exist "Y:\pre-install\preinstall.json" (
|
|
mkdir %OSDRIVE%\PreInstall 2>NUL
|
|
mkdir %OSDRIVE%\PreInstall\installers 2>NUL
|
|
robocopy "Y:\pre-install" "%OSDRIVE%\PreInstall" "preinstall.json" /R:1 /W:1 /NFL /NDL /NJH /NJS
|
|
if exist "Y:\pre-install\installers" (
|
|
robocopy "Y:\pre-install\installers" "%OSDRIVE%\PreInstall\installers" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: pre-install\installers robocopy FAILED - nothing staged.
|
|
) else (
|
|
echo Staged preinstall bundle to %OSDRIVE%\PreInstall.
|
|
)
|
|
echo [%TIME%] Staged preinstall bundle >> "%STAGELOG%"
|
|
) else (
|
|
echo WARNING: Y:\pre-install\installers not found - preinstall.json staged without installers.
|
|
)
|
|
if exist "Y:\pre-install\udc-backups" (
|
|
robocopy "Y:\pre-install\udc-backups" "%OSDRIVE%\PreInstall\udc-backups" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: pre-install\udc-backups robocopy FAILED - nothing staged.
|
|
) else (
|
|
echo Staged UDC settings backups to %OSDRIVE%\PreInstall\udc-backups.
|
|
)
|
|
echo [%TIME%] Staged UDC backups >> "%STAGELOG%"
|
|
)
|
|
) else (
|
|
echo No preinstall bundle on PXE server - skipping.
|
|
)
|
|
|
|
REM --- Stage CMM bootstrap bundle (CMM-type PCs only) ---
|
|
REM Copies the Hexagon installer bundle (~1.9 GB) from the PXE server enrollment
|
|
REM share onto the target disk so 09-Setup-CMM.ps1 can install from local disk.
|
|
REM The tsgwp00525 SFLD share that holds the canonical copy is not yet reachable
|
|
REM during shopfloor-setup (Azure DSC provisions those creds later), so this
|
|
REM bootstrap exists to get the first-install through. Post-imaging, the
|
|
REM unified GE-Enforce dispatcher takes over from the share for ongoing updates.
|
|
if /i not "%PCTYPE%"=="gea-shopfloor-cmm" goto skip_cmm_stage
|
|
if exist "Y:\installers-post\cmm\cmm-manifest.json" (
|
|
mkdir %OSDRIVE%\CMM-Install 2>NUL
|
|
REM /XD the backups tree: it holds EVERY bay's settings backup (some 240 MB
|
|
REM each). Copying all of it to every imaged CMM would waste GBs. The bulk
|
|
REM copy excludes it; the selected bay's backup is staged separately below.
|
|
robocopy "Y:\installers-post\cmm" "%OSDRIVE%\CMM-Install" /E /XD "Y:\installers-post\cmm\backups" /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: cmm robocopy FAILED - CMM bootstrap NOT staged.
|
|
) else (
|
|
echo Staged CMM bootstrap to %OSDRIVE%\CMM-Install.
|
|
)
|
|
echo [%TIME%] Staged CMM bootstrap >> "%STAGELOG%"
|
|
) else (
|
|
echo WARNING: Y:\cmm-installers not found - CMM PC cannot install Hexagon apps at imaging time.
|
|
)
|
|
REM Stage ONLY the selected bay's settings backup. 09-Setup-CMM's Restore-CMM
|
|
REM reads %OSDRIVE%\CMM-Install\backups\%CMMID%\ to restore PC-DMIS + goCMM settings.
|
|
if not defined CMMID goto skip_cmm_stage
|
|
if exist "Y:\installers-post\cmm\backups\%CMMID%" (
|
|
robocopy "Y:\installers-post\cmm\backups\%CMMID%" "%OSDRIVE%\CMM-Install\backups\%CMMID%" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: %CMMID% backup robocopy FAILED - settings will NOT restore.
|
|
echo [%TIME%] FAILED: %CMMID% backup robocopy >> "%STAGELOG%"
|
|
) else (
|
|
echo Staged %CMMID% settings backup for restore.
|
|
echo [%TIME%] Staged %CMMID% backup >> "%STAGELOG%"
|
|
)
|
|
)
|
|
:skip_cmm_stage
|
|
|
|
REM --- Stage Keyence per-model bootstrap bundle (Keyence PCs only) ---
|
|
REM Copies only the selected model's MSI + Data cabs from the PXE enrollment
|
|
REM share to the target disk. installers-post/keyence/<model>/ contains:
|
|
REM manifest.json
|
|
REM installers/{MSI, Data1.cab, [Data11.cab for vr3000], 1033.mst}
|
|
REM drivers/ (vr6000 only - older external .inf; vr3000/vr5000 drivers
|
|
REM are embedded in their MSIs)
|
|
REM 09-Setup-Keyence.ps1 reads C:\Enrollment\keyence-model.txt to know which.
|
|
if /i not "%PCTYPE%"=="gea-shopfloor-keyence" goto skip_keyence_stage
|
|
if "%KEYENCEMODEL%"=="" goto skip_keyence_stage
|
|
if exist "Y:\installers-post\keyence\%KEYENCEMODEL%\manifest.json" (
|
|
mkdir %OSDRIVE%\KeyenceInstall 2>NUL
|
|
mkdir %OSDRIVE%\KeyenceInstall\%KEYENCEMODEL% 2>NUL
|
|
robocopy "Y:\installers-post\keyence\%KEYENCEMODEL%" "%OSDRIVE%\KeyenceInstall\%KEYENCEMODEL%" /E /MT:16 /R:1 /W:1 /NFL /NDL /LOG+:"%STAGELOG%"
|
|
if errorlevel 8 (
|
|
echo WARNING: keyence\%KEYENCEMODEL% robocopy FAILED - nothing staged.
|
|
) else (
|
|
echo Staged Keyence %KEYENCEMODEL% bootstrap to %OSDRIVE%\KeyenceInstall\%KEYENCEMODEL%\.
|
|
)
|
|
echo [%TIME%] Staged Keyence %KEYENCEMODEL% >> "%STAGELOG%"
|
|
) else (
|
|
echo WARNING: Y:\installers-post\keyence\%KEYENCEMODEL% not found - Keyence %KEYENCEMODEL% cannot install at imaging time.
|
|
)
|
|
:skip_keyence_stage
|
|
|
|
REM --- Stage WaxTrace bootstrap bundle (wax/trace gea-shopfloor-waxtrace only) ---
|
|
REM Three-step process:
|
|
REM 1. robocopy installers-post\waxtrace -> %OSDRIVE%\WaxTrace-Install (everything
|
|
REM EXCEPT the formtracepak\ subdir, via /XD - that subdir carries all
|
|
REM 7 vendor ISOs and we only need one of them)
|
|
REM 2. resolve-bay-config.ps1: reads bay-config.csv + asset_tag, writes
|
|
REM %OSDRIVE%\Enrollment\waxtrace\{version,model,userid}.txt for 09-Setup to read
|
|
REM 3. robocopy ONLY the bay's matching FORMTRACEPAK-V<ver>.iso from
|
|
REM Y:\installers-post\waxtrace\formtracepak\ onto the target disk
|
|
REM (so 09-Setup-WaxAndTrace.ps1 mounts the right version per bay)
|
|
if /i not "%PCTYPE%"=="gea-shopfloor-waxtrace" goto skip_waxtrace_stage
|
|
if not exist "Y:\installers-post\waxtrace\waxtrace-manifest.json" goto skip_waxtrace_missing
|
|
mkdir %OSDRIVE%\WaxTrace-Install 2>NUL
|
|
REM robocopy /XD excludes the formtracepak\ dir up front so we don't waste
|
|
REM disk + time copying 12+ GB of vendor ISOs only to delete them. The
|
|
REM matched FTPak ISO gets cherry-picked below into the same target dir.
|
|
REM /NFL/NDL keep the listing manageable; output left visible (no >NUL) so
|
|
REM any failure is debuggable from the install log. robocopy exit codes
|
|
REM 0-7 are "OK" (per Microsoft); 8+ is real failure.
|
|
robocopy "Y:\installers-post\waxtrace" "%OSDRIVE%\WaxTrace-Install" /E /XD formtracepak /MT:16 /R:1 /W:1 /NFL /NDL
|
|
REM Both tests read the robocopy result, so they must sit before any command
|
|
REM that sets its own errorlevel - mkdir does, which is why it moved below.
|
|
if errorlevel 8 echo WARNING: WaxTrace bootstrap robocopy FAILED - nothing staged.
|
|
if not errorlevel 8 echo Staged WaxTrace bootstrap minus formtracepak\ to %OSDRIVE%\WaxTrace-Install.
|
|
mkdir %OSDRIVE%\WaxTrace-Install\formtracepak 2>NUL
|
|
REM Resolve bay-config: writes %OSDRIVE%\Enrollment\waxtrace\{version,model,userid}.txt
|
|
mkdir %OSDRIVE%\Enrollment\waxtrace 2>NUL
|
|
if not "%MACHINENUM%"=="" (
|
|
powershell.exe -NoProfile -ExecutionPolicy Bypass -File "Y:\installers-post\waxtrace\resolve-bay-config.ps1" -Asset "%MACHINENUM%" -OutDir "%OSDRIVE%\Enrollment\waxtrace"
|
|
) else (
|
|
echo WARNING: no MACHINENUM set - skipping bay-config resolve. 09-Setup-WaxAndTrace will abort cleanly with no version.
|
|
)
|
|
REM Read the resolved version + robocopy ONLY that FTPak ISO (avoids dumping
|
|
REM 12 GB of ISOs on the bay disk; only the matched ~2 GB ISO lands locally).
|
|
set WTVER=
|
|
if exist %OSDRIVE%\Enrollment\waxtrace\version.txt set /p WTVER=<%OSDRIVE%\Enrollment\waxtrace\version.txt
|
|
if not "%WTVER%"=="" (
|
|
if exist "Y:\installers-post\waxtrace\formtracepak\FORMTRACEPAK-V%WTVER%.iso" (
|
|
REM robocopy /J = unbuffered I/O, meaningfully faster than xcopy on
|
|
REM 2 GB FTPak ISOs over SMB. Single-file syntax: source dir, dest
|
|
REM dir, file pattern.
|
|
robocopy "Y:\installers-post\waxtrace\formtracepak" "%OSDRIVE%\WaxTrace-Install\formtracepak" "FORMTRACEPAK-V%WTVER%.iso" /J /R:1 /W:1 /NFL /NDL
|
|
echo Staged FormTracePak V%WTVER%.iso for %MACHINENUM%.
|
|
) else (
|
|
echo WARNING: No FORMTRACEPAK-V%WTVER%.iso on share for %MACHINENUM% - 09-Setup-WaxAndTrace will abort cleanly with the version-mismatch error.
|
|
)
|
|
) else (
|
|
echo WARNING: bay-config did not resolve a FTPak version for %MACHINENUM%.
|
|
)
|
|
REM Per-asset backup ZIPs land at %OSDRIVE%\WaxTrace-Install\backups\<asset>.zip
|
|
REM as part of the robocopy bundle above (backups\ is not in the /XD list).
|
|
REM 09-Setup-WaxAndTrace.ps1 Step 3b reads C:\WaxTrace-Install\backups\
|
|
REM <asset>.zip post-vendor-MSI and runs Install-FormtracepakSettings.ps1
|
|
REM -RestoreData -RestoreConfig. Total ~17 MB on disk for the whole set, no
|
|
REM cherry-pick needed.
|
|
if not "%MACHINENUM%"=="" (
|
|
if exist "%OSDRIVE%\WaxTrace-Install\backups\%MACHINENUM%.zip" (
|
|
echo Backup ZIP %MACHINENUM%.zip is in the bundle - 09-Setup Step 3b will restore.
|
|
) else (
|
|
echo INFO: No backup ZIP for %MACHINENUM% in %OSDRIVE%\WaxTrace-Install\backups - 09-Setup will skip the restore step.
|
|
)
|
|
)
|
|
goto skip_waxtrace_stage
|
|
:skip_waxtrace_missing
|
|
echo WARNING: Y:\installers-post\waxtrace not found - WaxTrace PC cannot install FormTracePak at imaging time.
|
|
:skip_waxtrace_stage
|
|
:pctype_done
|
|
if defined STAGELOG echo [%TIME%] WinPE staging complete >> "%STAGELOG%"
|
|
|
|
REM --- Verify what we just staged ------------------------------------------
|
|
REM Check the payload BEFORE anything depends on it, while a tech is still
|
|
REM standing at the machine. A short copy found here costs 30 seconds; the same
|
|
REM copy found at first logon costs 20 minutes, and found never costs a rebuild.
|
|
REM Four Display bays sat at "imaging stage 2, green" for weeks because nothing
|
|
REM checked. Retry once for the small trees; the ppkg is 8 GB so report it
|
|
REM rather than blindly re-pulling it.
|
|
if "%PCTYPE%"=="" goto verify_done
|
|
set STAGEBAD=
|
|
if not exist "%OSDRIVE%\Enrollment\pc-type.txt" set STAGEBAD=%STAGEBAD% pc-type.txt
|
|
if not exist "%OSDRIVE%\Enrollment\Run-ShopfloorSetup.ps1" set STAGEBAD=%STAGEBAD% Run-ShopfloorSetup.ps1
|
|
if not exist "%OSDRIVE%\Enrollment\shopfloor-setup\common" set STAGEBAD=%STAGEBAD% shopfloor-setup\common
|
|
if not exist "%OSDRIVE%\Enrollment\shopfloor-setup\%PCTYPE%" set STAGEBAD=%STAGEBAD% shopfloor-setup\%PCTYPE%
|
|
if "%STAGEBAD%"=="" goto verify_ppkg
|
|
|
|
echo.
|
|
echo Staging verify: missing%STAGEBAD% - retrying once...
|
|
echo [%TIME%] VERIFY: missing%STAGEBAD% - retry >> "%STAGELOG%"
|
|
robocopy "Y:\shopfloor-setup" "%OSDRIVE%\Enrollment" "Run-ShopfloorSetup.ps1" /R:2 /W:2 /NFL /NDL /NJH /NJS
|
|
robocopy "Y:\shopfloor-setup\common" "%OSDRIVE%\Enrollment\shopfloor-setup\common" /E /MT:16 /R:2 /W:2 /NFL /NDL /NJH /NJS
|
|
robocopy "Y:\shopfloor-setup\%PCTYPE%" "%OSDRIVE%\Enrollment\shopfloor-setup\%PCTYPE%" /E /MT:16 /R:2 /W:2 /NFL /NDL /NJH /NJS
|
|
if not exist "%OSDRIVE%\Enrollment\pc-type.txt" echo %PCTYPE%> %OSDRIVE%\Enrollment\pc-type.txt
|
|
|
|
set STAGEBAD=
|
|
if not exist "%OSDRIVE%\Enrollment\pc-type.txt" set STAGEBAD=%STAGEBAD% pc-type.txt
|
|
if not exist "%OSDRIVE%\Enrollment\Run-ShopfloorSetup.ps1" set STAGEBAD=%STAGEBAD% Run-ShopfloorSetup.ps1
|
|
if not exist "%OSDRIVE%\Enrollment\shopfloor-setup\common" set STAGEBAD=%STAGEBAD% shopfloor-setup\common
|
|
if not exist "%OSDRIVE%\Enrollment\shopfloor-setup\%PCTYPE%" set STAGEBAD=%STAGEBAD% shopfloor-setup\%PCTYPE%
|
|
if "%STAGEBAD%"=="" (
|
|
echo Staging verify: retry fixed it.
|
|
echo [%TIME%] VERIFY: retry succeeded >> "%STAGELOG%"
|
|
goto verify_ppkg
|
|
)
|
|
echo.
|
|
echo ******************************************************************
|
|
echo STAGING INCOMPLETE after retry:%STAGEBAD%
|
|
echo This bay will image but the post-install setup will NOT run
|
|
echo properly. Fix the share and re-image. Tell the PXE admin.
|
|
echo ******************************************************************
|
|
echo.
|
|
echo [%TIME%] VERIFY FAILED after retry:%STAGEBAD% >> "%STAGELOG%"
|
|
|
|
:verify_ppkg
|
|
REM The enrollment package is the expensive one - 8 GB. Report, do not re-pull.
|
|
if "%PPKG%"=="" goto verify_done
|
|
if exist "%OSDRIVE%\Enrollment\%PPKG%" (
|
|
echo Staging verify: enrollment package present.
|
|
echo [%TIME%] VERIFY: %PPKG% present >> "%STAGELOG%"
|
|
) else (
|
|
echo.
|
|
echo WARNING: enrollment package %PPKG% is MISSING from %OSDRIVE%\Enrollment.
|
|
echo Enrollment will not run. Re-image this bay.
|
|
echo.
|
|
echo [%TIME%] VERIFY FAILED: %PPKG% missing >> "%STAGELOG%"
|
|
)
|
|
:verify_done
|
|
|
|
REM --- BIOS update sub-stage push (fires AFTER %OSDRIVE% copies complete) ---
|
|
REM check-bios.cmd drops X:\bios-fired.flag iff it actually flashed or
|
|
REM staged a firmware update. Reading the flag file is more reliable than
|
|
REM scanning BIOS_STATUS for substrings (caret escaping inside quoted SET
|
|
REM is subtle in WinPE cmd.exe). Push must happen before Y: cleanup since
|
|
REM the push script lives on the share.
|
|
if exist X:\bios-fired.flag (
|
|
if exist "Y:\scripts\winpe-status-push.ps1" (
|
|
powershell -NoProfile -ExecutionPolicy Bypass -File "Y:\scripts\winpe-status-push.ps1" -CurrentStage "WinPE: BIOS firmware update"
|
|
)
|
|
)
|
|
|
|
:cleanup_enroll
|
|
net use Y: /delete 2>NUL
|
|
|
|
:wait_finish
|
|
ping -n 11 127.0.0.1 >NUL
|
|
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
|
|
if not errorlevel 1 goto wait_finish
|
|
|
|
REM --- Harvest the imaging logs to the share --------------------------------
|
|
REM Every diagnosis of a failed build so far has meant walking to the bay and
|
|
REM copying files off by hand. PESetup preserves its log and the generated
|
|
REM unattend, DISM writes its apply logs, and our staging log sits on the target
|
|
REM - all of it is thrown away at reboot unless collected now. Runs after
|
|
REM PESetup exits so the logs are final, which means re-mapping Y: (cleanup
|
|
REM already dropped it).
|
|
REM Best-effort throughout: a bay must never fail to reboot because a log copy
|
|
REM did not work.
|
|
set SERIAL=
|
|
for /f "skip=1 tokens=*" %%S in ('wmic bios get serialnumber 2^>NUL') do if not defined SERIAL set SERIAL=%%S
|
|
for /f "tokens=*" %%a in ("%SERIAL%") do set SERIAL=%%a
|
|
if "%SERIAL%"=="" set SERIAL=unknown-serial
|
|
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no >NUL 2>&1
|
|
if not exist "Y:\" goto harvest_done
|
|
set LOGDEST=Y:\imaging-logs\%SERIAL%
|
|
mkdir "Y:\imaging-logs" 2>NUL
|
|
mkdir "%LOGDEST%" 2>NUL
|
|
echo Collecting imaging logs to %LOGDEST% ...
|
|
|
|
REM WinPE side: DISM apply logs, the unattend PESetup generated, BIOS flash log.
|
|
robocopy X:\ "%LOGDEST%" "*.log" "Unattend.xml" /R:1 /W:1 /NFL /NDL /NJH /NJS >NUL 2>&1
|
|
REM Target side: PESetup's own log lands in Panther, and our staging log.
|
|
if defined OSDRIVE (
|
|
robocopy "%OSDRIVE%\Windows\Panther" "%LOGDEST%" "PESetup*.log" /R:1 /W:1 /NFL /NDL /NJH /NJS >NUL 2>&1
|
|
robocopy "%OSDRIVE%\Enrollment" "%LOGDEST%" "winpe-staging.log" /R:1 /W:1 /NFL /NDL /NJH /NJS >NUL 2>&1
|
|
)
|
|
REM A breadcrumb of what this build actually was, so the logs are readable
|
|
REM without cross-referencing the webapp.
|
|
> "%LOGDEST%\build-context.txt" (
|
|
echo Serial=%SERIAL%
|
|
echo PCTYPE=%PCTYPE%
|
|
echo PPKG=%PPKG%
|
|
echo MACHINENUM=%MACHINENUM%
|
|
echo CMMID=%CMMID%
|
|
echo KEYENCEMODEL=%KEYENCEMODEL%
|
|
echo DISPLAYTYPE=%DISPLAYTYPE%
|
|
echo OSDRIVE=%OSDRIVE%
|
|
echo Media=%MEDIAPATH%
|
|
echo Date=%DATE% %TIME%
|
|
)
|
|
echo Imaging logs collected.
|
|
net use Y: /delete /y >NUL 2>&1
|
|
:harvest_done
|
|
|
|
echo.
|
|
echo Imaging complete. Rebooting in 15 seconds...
|
|
echo Press Ctrl+C to cancel.
|
|
ping -n 16 127.0.0.1 >NUL
|
|
wpeutil reboot
|