cproudlock a22d2f0313 Stage-Dispatcher: top up AutoLogonCount during shopfloor-setup stage
Unattend XML sets LogonCount=7 for SupportUser autologon. Each interactive
login decrements the counter; at 0 Windows clears AutoAdminLogon and the
bay parks at the login screen with no one to fire RunOnce -> dispatcher
never re-runs -> imaging chain stalls.

Typical imaging burns several logons: Windows OOBE first logon,
post-Office reboot, Oracle install reboot, FormTracePak Setup.exe forced
reboot, Run-ShopfloorSetup's own shutdown /r at end of script, stage
advances. The unplanned FormTracePak reboot pushes the count past 0 on
some bays - the exact failure mode the WJF00159 imaging today hit, where
Stage-Dispatcher.ps1 had the new defensive RunOnce-re-register fix
landed but the dispatcher still never re-fired because there was no
auto-logon to trigger it.

Top up AutoLogonCount to 10 every time the dispatcher hits the
'shopfloor-setup' stage. Restores the autologon budget across any
vendor-forced reboots that fire during the stage. When sync-intune
finishes the whole pipeline, AutoLogonCount is left to decrement
naturally; by then lockdown's Autologon.exe has set its own
AutoAdminLogon for the ShopFloor user.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 08:59:22 -04:00
..