cproudlock bc422649e9 NIC guard: dnsmasq never serves DHCP/PXE on the GE network
pxe-nic-check classifies each NIC from what it hears: LLDP/CDP/802.1X
from managed switches, foreign DHCP offers and their domain (one
DHCPDISCOVER on the imaging NIC; the GE NIC's networkd lease is read
instead), STP and ARP hosts for information. A kernel BPF filter keeps
bulk SMB traffic out of the capture loop; bridge ports are listened on
too, since LLDP and EAPOL stop at the port.

- dnsmasq drop-in runs --guard as ExecStartPre: exit 1 on a ge or
  foreign-dhcp imaging verdict, fail open (loudly) on bugs or no link
- pxe-nic-check.timer runs --watch every 5 min: stops dnsmasq on a bad
  imaging verdict, never starts it
- /run/pxe-nic-status.json (0644, atomic) for the webapp
- playbook installs it all and writes /etc/pxe-server/nic.conf from
  pxe_imaging_mac, pxe_ge_mac, pxe_corp_domain_suffixes,
  pxe_nic_allowed_switches
- unit tests plus a no-root network-namespace lab (veth pairs, a raw
  socket DHCP/LLDP peer and real dnsmasq); docs/pxe-nic-guard.md has the
  operator notes and the two floor tests
2026-10-14 17:18:53 -04:00

8.1 KiB

PXE NIC guard

The PXE server's DHCP/PXE (dnsmasq) must never serve on the GE corporate network. Each server has two NICs:

Role Network Address
imaging isolated imaging switch static 172.16.9.1/24, dnsmasq
ge GE corporate network DHCP client (systemd-networkd)

/etc/dnsmasq.d/pxe-nic-only.conf pins dnsmasq to the imaging NIC by name. That stops dnsmasq answering on the GE NIC, but not on the imaging NIC when that NIC itself ends up on the wrong network: a cable swap, an imaging switch uplinked into a GE port, or a second PXE server on the same switch. The NIC guard catches those.

What is installed

File Purpose
/usr/local/sbin/pxe-nic-check the classifier
/etc/pxe-server/nic.conf which NIC is which
/etc/systemd/system/dnsmasq.service.d/nic-guard.conf guard before every dnsmasq start
/etc/systemd/system/pxe-nic-check.{service,timer} watch every 5 min
/run/pxe-nic-status.json last result, read by the webapp

Sources: playbook/pxe-server-helpers/, installed by pxe_server_setup.yml (vars pxe_imaging_mac, pxe_ge_mac, pxe_corp_domain_suffixes, pxe_nic_allowed_switches).

How it decides

It listens on each NIC (raw socket, sends nothing) for:

  • LLDP and CDP: managed switches announce themselves. GE switches do; the unmanaged imaging switch does not.
  • 802.1X EAPOL: GE ports ask for port authentication.
  • DHCP OFFER/ACK from any other server.
  • STP and the count of distinct ARP hosts: reported, never decisive.

On the imaging NIC it also sends one DHCPDISCOVER and collects offers for 6 s. On the GE NIC it reads the networkd lease instead (no traffic).

Verdict Meaning
isolated no foreign DHCP, no LLDP/CDP/EAPOL
ge LLDP, CDP or EAPOL seen, or a DHCP server whose domain ends in a corp suffix (geaerospace.net, ge.com; whole labels, so notgeaerospace.net does not count)
foreign-dhcp another DHCP server, no corp domain
no-link no carrier
error the check itself failed

Healthy: imaging NIC isolated (or no-link), GE NIC ge.

Our own dnsmasq never counts. An offer whose server id is our own address but comes from a MAC that is not ours is a second PXE server and DOES count.

If the imaging switch is itself a managed switch that sends LLDP/CDP, put its LLDP system name, CDP device id or chassis MAC in allowed_switches (pxe_nic_allowed_switches), or the guard will block dnsmasq. 802.1X is never allowed.

Modes

  • pxe-nic-check - check every NIC (60 s), print a summary. --json, --write, --probe (imaging DHCP probe), --iface NAME, --window S.
  • pxe-nic-check --guard - dnsmasq ExecStartPre. Imaging NIC only, about 6 s. Exit 1 = do not serve: dnsmasq does not start. A bug or no link exits 0 (fail open) with an error line in the journal.
  • pxe-nic-check --watch - the timer. On a bad imaging verdict it runs systemctl stop dnsmasq and logs CRIT. It never starts dnsmasq.

Every start or restart of dnsmasq runs the guard, so systemctl restart dnsmasq and the @reboot cron restart take about 6 s longer than before.

Reading it

sudo pxe-nic-check                       # full summary, 60 s
cat /run/pxe-nic-status.json             # last guard/watch result
journalctl -u dnsmasq -b | grep pxe-nic-check
journalctl -u pxe-nic-check -b

dnsmasq will not start

  1. journalctl -u dnsmasq -b | grep pxe-nic-check shows the evidence, e.g. REFUSING to start dnsmasq: imaging NIC br-pxe verdict ge: LLDP from WJ-IDF2 port Gi1/0/14.
  2. Check the imaging cabling: the imaging NIC must go to the imaging switch only, and that switch must not be uplinked anywhere.
  3. sudo pxe-nic-check until the imaging NIC reads isolated.
  4. sudo systemctl start dnsmasq (runs the guard again).

Floor tests (run with the floor idle)

Both tests stop imaging for a few minutes. Have console or GE-side SSH access to the server; do not rely on the imaging network for the session.

(a) Rogue DHCP on the imaging switch: expect the alarm

  1. Confirm the baseline: sudo pxe-nic-check --probe shows the imaging NIC isolated and dnsmasq_bound true.
  2. Plug a device that runs a DHCP server into a free port of the IMAGING switch (a spare home router with DHCP on, LAN port only, nothing in its WAN port; or a laptop running dnsmasq).
  3. Run the watch now instead of waiting up to 5 min: sudo systemctl start pxe-nic-check.service
  4. Expect:
    • journalctl -u pxe-nic-check -n 20 has a CRIT line imaging NIC is NOT isolated, stopping dnsmasq: ... verdict foreign-dhcp: DHCP from 192.168.x.1, ... (or ge if the router sends LLDP).
    • systemctl is-active dnsmasq is inactive.
    • /run/pxe-nic-status.json has "dhcp_guard": {"state": "blocked", ...}.
  5. Prove the guard too: sudo systemctl start dnsmasq must FAIL, and journalctl -u dnsmasq -n 20 shows REFUSING to start dnsmasq.
  6. Unplug the rogue device. sudo pxe-nic-check --probe shows isolated. sudo systemctl start dnsmasq starts. PXE-boot one client to confirm.

(b) Cable swap into a GE port: expect the guard to refuse dnsmasq

dnsmasq must be stopped BEFORE the cable moves, so it never serves on GE.

  1. sudo systemctl stop dnsmasq; systemctl is-active dnsmasq must say inactive. Do not reboot during the test (the @reboot cron restarts dnsmasq; the guard would still block it, but do not test that way).
  2. Move the IMAGING NIC's cable from the imaging switch into a live GE network port. Wait for link: ip -br link shows the imaging NIC UP.
  3. Run the guard by hand first: sudo pxe-nic-check --guard; echo "exit $?" Expect exit 1 and a REFUSING to start dnsmasq line naming LLDP/CDP, 802.1X, or DHCP from 10.x.x.x, domain ....geaerospace.net. This sends one DHCPDISCOVER on the GE port, the same as any PC being plugged in. To send nothing, use --no-probe --window 60 instead and rely on LLDP/CDP/802.1X (switches announce every 30-60 s). If it exits 0, STOP: do not start dnsmasq. Move the cable back and send the output of sudo pxe-nic-check --probe --json.
  4. Only after step 3 exited 1: sudo systemctl start dnsmasq. Expect Job for dnsmasq.service failed; systemctl is-active dnsmasq says failed; journalctl -u dnsmasq -n 20 shows REFUSING.
  5. Move the cable back to the imaging switch. sudo pxe-nic-check --probe shows the imaging NIC isolated. sudo systemctl start dnsmasq starts. PXE-boot one client to confirm.

Status file

/run/pxe-nic-status.json, mode 0644, replaced atomically:

{"checked_at": "2026-10-14T16:47:09-04:00", "duration_s": 60,
 "dhcp_guard": {"state": "allowed"|"blocked"|"unknown", "reason": "..."},
 "interfaces": [{"iface": "br-pxe", "mac": "aa:bb:..", "role": "imaging"|"ge"|"other",
   "link": "up"|"down", "speed_mbps": 5000, "addrs": ["172.16.9.1/24"],
   "verdict": "isolated"|"ge"|"foreign-dhcp"|"no-link"|"error", "evidence": ["..."],
   "dhcp_servers": [{"server": "10.1.2.3", "domain": "x.geaerospace.net", "own": false}],
   "switch": {"lldp": [{"system": "...", "port": "...", "vlan": null}],
              "cdp": [{"device": "...", "port": "..."}], "eapol": false, "stp": false},
   "arp_hosts": 3, "dnsmasq_bound": true}]}

dnsmasq_bound is null when it cannot be told (no ss). A bridge (br-pxe) is reported as one interface; its ports are listened on too, because LLDP and 802.1X frames stop at the port and never reach the bridge.