goCMM settings live in two places: 3 pointer values at HKLM\SOFTWARE\WOW6432Node\General Electric\goCMM, and the real content of all 7 Settings tabs (PC-DMIS, Quindos, Modus, Machine Definition, User Input, Notifications, Part Groups) in C:\geaofi\ApplicationSettings.xml. Capture-replay pair, mirroring the Wax/Trace Backup/Install scripts: - Backup-goCMMSettings.ps1/.bat: on a live legacy bay (admin), zips the registry key + the C:\geaofi tree (minus transient LocalProgramCopies/logs) to gocmm_backup_<PC>_<ts>.zip. - Install-goCMMSettings.ps1/.bat: restore at imaging (admin). Imports the key + lays down C:\geaofi, then grants BUILTIN\Users WriteKey on the reg key and Modify on C:\geaofi - goCMM's RegistrySettings.GetRegistryString opens the key with writable:true even to READ, so a locked-down operator throws a SecurityException without the grant (the post-lockdown 'registry access not allowed' error). Applies a built-in legacy->new FQDN rewrite (rd.ds.ge.com -> wjs.geaerospace.net) automatically across the registry values and ApplicationSettings.xml (incl PartGroup FullName); -NoDefaultRewrite skips it, /replace adds an extra pair, -SelectedPartGroup overrides per bay. - gocmm-debug.ps1/.bat: run as the operator to reproduce the SecurityException and dump the goCMM key ACL (confirms whether lockdown stripped the grant). All round-trip + FQDN-rewrite verified on the win11 VM. NOTE: covers goCMM only; PC-DMIS probe calibrations / custom tip angles / machine comp are owned by PC-DMIS (Hexagon) and not captured here. Not yet wired into 09-Setup-CMM auto-discovery. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
20 lines
816 B
Batchfile
20 lines
816 B
Batchfile
@echo off
|
|
REM Backup-goCMMSettings.bat - capture this bay's goCMM settings.
|
|
REM
|
|
REM Run on a LIVE legacy goCMM device, AS ADMINISTRATOR (reg export of HKLM +
|
|
REM read of C:\geaofi needs admin). Captures the registry pointers + the whole
|
|
REM Shared Data Directory (ApplicationSettings.xml = all 7 Settings tabs) into
|
|
REM one zip under C:\Logs\CMM\gocmm-backup\.
|
|
REM
|
|
REM Backup-goCMMSettings.bat (default output dir)
|
|
REM Backup-goCMMSettings.bat -OutDir D:\path
|
|
|
|
setlocal
|
|
set "HERE=%~dp0"
|
|
powershell.exe -NoProfile -ExecutionPolicy Bypass -File "%HERE%Backup-goCMMSettings.ps1" %*
|
|
echo.
|
|
echo ---------------------------------------------------------------
|
|
echo Backup zip is under C:\Logs\CMM\gocmm-backup\ (gocmm_backup_*.zip)
|
|
echo ---------------------------------------------------------------
|
|
pause
|