Recurring Phase 2 "Device Configuration" stuck: GE Intune Proactive
Remediation "Report IP" script enumerates Get-NetIPAddress and POSTs
all IPs to a GE webhook. Bays cabled to air-gapped PXE LAN have
10.9.100.x leak into that report. GE backend tags bays "not on corp
net" -> dynamic-group assignment-filter at GE excludes them from the
SFLD ConfigurationProfile (Function + SasToken OMA-URI) ->
HKLM:\SOFTWARE\GE\SFLD\DSC never populates -> Monitor Phase 2 gate
never closes. Confirmed via mdm-diag-F907T5X3 dump: every Microsoft
policy delivered fine, zero SFLD/GE-namespace OMA-URI present.
Fix flow:
1. Run-ShopfloorSetup line 43: disable every Up wired NIC right after
stage 2 push. NIC names persisted to
C:\Enrollment\disabled-wired-nics.txt for later re-enable.
2. Stages 3-6 status pushes fail silently while wired is down (PXE
server lives on the air-gapped 10.9.100.0/24 LAN, unreachable from
WiFi). Dashboard goes dark in that window.
3. PPKG installs, immediate reboot, AAD/Intune enroll over WiFi only.
4. IME boots, Report IP script fires with corp-WiFi IP only, writes
C:\Logs\GE_Report_IP_Address*.txt. Webhook records clean IP. GE
dynamic group eligibility flips. SFLD policy delivers next sync.
5. Monitor-IntuneProgress detects the log file, re-enables every NIC
in the persisted list, sleeps 1s for link, then pushes idx=7 with
DeviceId so the dashboard card flips to QR before the Intune-
triggered LAPS-prompt reboot lands.
Phase 1 remains "in progress" on the dashboard until Report IP fires
- correct, the bay isn't actually registration-clean until then.
Files:
- Disable-WiredNics.ps1 (new) - persists names + disables
- Run-ShopfloorSetup.ps1 - call after stage 2 Report-Stage
- Monitor-IntuneProgress.ps1 - gate idx=7 push + re-enable
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>