Files
pxe-server/playbook/shopfloor-setup/gea-shopfloor-keyence/vr5000/manifest.json
cproudlock 37357eee43 Shopfloor images: add Wax/Trace + Keyence per-model variants
Wax/Trace (gea-shopfloor-waxtrace):
- captured/ holds master FormTracePak v6.0 state (Program Files reg dump
  gzipped, ARP entries) taken from a win11 VM where the CD-ROM-bound VB6
  wrapper was driven to completion. xcopy + reg-import replays the install
  on real bays without running the wrapper itself.
- 09-Setup-WaxAndTrace.ps1 rewrites the stub: installs prereqs via manifest
  (VC++ 2008/2017 x86+x64, Sentinel HASP), expands the captured zips into
  C:\Program Files (x86)\MitutoyoApp + C:\MitutoyoApp, imports the reg
  hive, then mounts the bay's per-machine cal ISO (matched by asset tag
  in machine-number.txt) and runs its Setup.exe.
- waxtrace-manifest.json lists the 5 prereqs with InstallShield-style
  silent flags verified on the win11 VM.
- sync-waxtrace.sh ships captured-binary/ + prereqs + cal ISOs from
  /home/camp/pxe-images/iso/mitutoyo-cal/ to
  /srv/samba/enrollment/installers-post/waxtrace/ on the PXE box.
- select-waxtrace-asset.ps1 arrow-key bay picker for WinPE (parses
  INDEX.csv from the cal share, offers "Other (new bay)" fallback).
- startnet.cmd: prompt_waxtrace_asset prompt, skip_waxtrace_stage xcopy
  block (mirrors :skip_cmm_stage), machine-number.txt write covers bay
  asset tag (WJRP*).

Keyence (gea-shopfloor-keyence) - now multi-model:
- vr3000/manifest.json + vr5000/manifest.json + vr6000/manifest.json
  (current single-model VR-6000 moved into vr6000/ subdir). Each ships
  the model's MSI silent-install + DetectionPath via ProductCode.
  Big payloads (Data1.cab, Data11.cab) gitignored, staged via
  sync-keyence.sh from /home/camp/pxe-images/iso/keyence/.
- 09-Setup-Keyence.ps1 dispatches by C:\Enrollment\keyence-model.txt
  (written by startnet.cmd in :keyence_submenu) and points
  InstallerRoot at C:\KeyenceInstall\<model>. DXSETUP probe widened
  to all three Program Files paths (VR-3000 G2, VR-5000, VR-6000).
- startnet.cmd: :keyence_submenu picks vr3000/vr5000/vr6000,
  :skip_keyence_stage xcopy block selectively stages chosen model bundle,
  pc-subtype.txt also written = drops directly into existing GE-Enforce
  PCSubType wiring (looks for gea-shopfloor-keyence-<model>\manifest.json
  on the tsgwp00525 share for ongoing enforcement, no dispatcher change
  needed).
- sync-keyence.sh mirrors sync-waxtrace.sh pattern.

Verified silent MSI install for VR-3000 G2 v2.5.0 and VR-5000 v3.3.1 on
the win11 VM 2026-05-18 with /qn /norestart ALLUSERS=1 REBOOT=ReallySuppress
TRANSFORMS=1033.mst. boot.wim on 172.16.9.1 wimupdate'd with the new
startnet.cmd.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-18 16:34:20 -04:00

18 lines
1.1 KiB
JSON

{
"Version": "1.0",
"_comment": "Keyence VR-5000 imaging-time manifest. Consumed by 09-Setup-Keyence.ps1 when keyence-model.txt = vr5000. USB drivers embedded in MSI (newer InstallShield). MSI references Data1.cab (702 MB) in installers/ - gitignored, stage from /home/camp/pxe-images/iso/keyence/Keyence-VR-5000-v3.3.1.iso. Verified silent install via msiexec on Win11 2026-05-18.",
"Applications": [
{
"_comment": "VR-5000 Series Software v3.3.1 Nov 2018. ProductCode {AF7E8B93-DBEB-4DB1-91CB-4DA592D8E222}. Same bypass-bootstrapper pattern: call MSI directly skipping the InstallShield setup.exe (203 MB - prereq bundle we don't need).",
"Name": "VR-5000 Series Software",
"Installer": "installers\\VR-5000 Series Software.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ALLUSERS=1 REBOOT=ReallySuppress TRANSFORMS=installers\\1033.mst",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{AF7E8B93-DBEB-4DB1-91CB-4DA592D8E222}",
"DetectionName": "DisplayVersion",
"DetectionValue": "3.3.1"
}
]
}