cproudlock e40a294193 Back up what a part marker holds, without the vendor tool
Telesis pinstamp controllers have never been backed up. The vendor's own
utilities, Backup470 and Backup420, are GUIs with no command line, so nothing
could capture a marker on a schedule - and a controller swap meant retyping
patterns from memory.

TelesisMarker.psm1 speaks the protocol directly, reversed from a capture of
Backup470 against a TMC470 and verified against hardware: a pattern pulled by
this code is byte-identical to the one the vendor tool saves, and a pattern
written back survives a power cycle. A TMC420 was captured the same way and
differs in exactly one respect - it exposes no parameter files - so one
implementation covers both families, with content classes chosen from a Type I
status probe rather than a per-model dialect.

Backup-PartMarker.ps1 captures everything the controller holds into a
timestamped snapshot on the share and records it in ShopDB against the marker
asset. Snapshots rather than a mirrored directory, because a mirror forces a
choice between deleting the only copy of a retired pattern and claiming a
pattern that no longer exists; a snapshot has neither problem, and the manifest
hash means an unchanged controller writes nothing.

The marker's serial port is shared with eDNC and is exclusive-open, so captures
happen only at shift changes - 14:00 normally, when someone is on site to fix a
problem, with 06:00 and 22:00 engaging only once the backup is overdue. The
capture yields the port within a second if the marker application starts
mid-run, and cycles missed to a busy port are counted and carried into the next
snapshot, since posting a no-op to keep the health badge green would hide
exactly the failure the badge exists to report.

TYPE 'R' deletes a file on the controller, immediately and without
confirmation. It is documented in the module header and deliberately not
implemented.