docs: wiki update for API docs, printer installer, geenforce cutover, timezone
Execute WIKI-UPDATE-PLAN.md (14 items): - NEW docs/PRINTER-INSTALLER.md: install-list / pc-default / install-batch contract + public installer map page. - NEW-shape docs/API-REFERENCE.md: index + pointer to the live generated docs (/api/docs Redoc, openapi.json, llms.txt, MCP), replacing a stale full dump. - geenforce cutover + GE-ENFORCE-DISPLAY/CLIENT/DEPLOY: server-first display dispatcher (display-role by FQDN, display-type.txt fallback), dashboarddefaults FQDN keying, legacy kiosk autostart self-heal (Wow6432Node), per-PC-type cutover status. - PLUGINS: printers/slides rows + plugin-permissions note (slides.manage). - IMPORT-API: dashboarddefaults FQDN-first keying. - CONFIG: word-wise search, site_timezone setting. - PILOT-DEPLOY: servers-to-network reclassify step. IMPORT-ADOPTION: fixup note. - CLAUDE.md: test count 1077->1159, HTTPS-cutover state. CHANGELOG: timezone + kiosk-autostart fixes, site_timezone setting.
This commit is contained in:
@@ -234,10 +234,13 @@ upload them after import via `POST /api/models/<modelid>/image` (multipart
|
||||
| `pctype` | `POST /api/computers/types` | `typename` -> `computertype`, `description` | `computertype` |
|
||||
| `subnettypes` | (see subnets) | used as `subnettype` string on subnets | - |
|
||||
| `subnets` | `POST /api/network/subnets` | `cidr`, `description` -> `name`/`description`, `vlan` -> create VLAN first (`POST /api/network/vlans`) then `vlanid`, `subnettypeid` -> `subnettype` name | `cidr` |
|
||||
| `dashboarddefaults` | `POST /api/dashboarddefaults` | `ipaddress` -> `ipaddress`, `businessunitid` (remapped), `description` | `ipaddress` |
|
||||
| `dashboarddefaults` | `POST /api/dashboarddefaults` | `fqdn` (preferred key, stored lowercase), `ipaddress` (fallback key), `displayrole` (`dashboard`/`lobby`/`partskiosk`), `businessunitid` (remapped; only the `dashboard` role uses it), `description` | `fqdn`, else `ipaddress` |
|
||||
| `controllertypes` | remap into `vendors` + `models` | e.g. "Fanuc" -> a Vendor; the controller model -> a Model; then set `controllervendorid`/`controllermodelid` on the machine | - |
|
||||
| `comstypes` | `communicationtypes` (seeded, no API) | ensure `flask seed reference-data` created IP/Serial/USB/... before importing comms | - |
|
||||
|
||||
Resolution at runtime is FQDN-first with IP fallback (migration
|
||||
`7d31_dashboarddefault_fqdn`); import both when the legacy source has them.
|
||||
|
||||
Note on communication types: the classic `comstypes.typename` values
|
||||
(IP, Serial, Network_Interface, USB, Parallel, VNC, FTP, DNC) correspond to the
|
||||
seeded `communicationtypes.comtype`. They are created by the reference-data seed,
|
||||
|
||||
Reference in New Issue
Block a user