Fix endpoint user-context collection running in the wrong session
Mapped drives reported Unavailable on endpoints where the operator could see them fine. The data path was intact; the collection was running under the wrong token. Mapped drives are per logon token, so an elevated probe enumerates a different drive table than the interactive user. Collection: - Pin the user-context spool path so the probe and service agree on one location, and persist/overwrite it instead of deleting on read. - Refuse to collect while elevated (exit code 2) rather than emitting a confident wrong answer, and stamp elevated/username on the spool. - Reject spools stamped elevated or from an unexpected account on read, so an admin run cannot masquerade as valid. - Log netuse/smbmapping/userlistener counts so each run leaves evidence of what it actually saw. Install and launch context: - Move collection to a 'ShopDB user-context probe' scheduled task under S-1-5-32-545 at RunLevel Limited, the only mechanism that reliably runs in the operator's own session. Verify registration and record it in the install ledger. - Stop starting the tray as a child of the elevated installer; explorer.exe de-elevates without changing ACCOUNT, so an admin install produced an admin tray. The Run key only fires at logon, which left the tray dead on a machine already signed in, so add a transient 'ShopDB tray first launch' task that starts it once in the existing session and unregisters itself. - Hide the console window during --collect-usercontext. The agent is a console exe; the tray used to mask this with CreateNoWindow, but the scheduled task invokes it directly and flashed a window every cycle. Installer edits are in _install_script() in plugins/endpoints/api/siteagent.py, which generates the install.ps1 that actually ships. The standalone agent/installer/install-shopdbagent.ps1 was never shipped once the package moved to the UI builder and is deleted here to stop the divergence that caused an earlier fix to land in a file no endpoint ever ran. Versions: agent 1.10.1, tray 1.3.0. These share the pinned spool path and must be deployed together. Pre-existing test failures unrelated to this work (8, identical on a clean tree): docs publishable/versions, plugin contract symlink scan, import guard tamper check, security headers upload sandbox, and three endpoint timestamp tests.
This commit is contained in:
@@ -84,12 +84,23 @@ event channel and system WMI.
|
||||
## Tray app (system-tray icon)
|
||||
|
||||
The tray is a per-user process, not a service, so it starts at sign-in rather
|
||||
than under `sc.exe`. `install-shopdbagent.ps1` handles it: it copies
|
||||
`shopdb-endpoint-tray.exe` next to the agent, registers an HKCU logon autostart
|
||||
(`Software\Microsoft\Windows\CurrentVersion\Run\ShopDbEndpointTray`), and
|
||||
launches it for the current user. Run the installer from the operator's own
|
||||
session so the autostart lands in the right user hive. Pass `-NoTray` for a
|
||||
headless, service-only install.
|
||||
than under `sc.exe`. The generated `install.ps1` handles it: it copies
|
||||
`shopdb-endpoint-tray.exe` next to the agent and registers a machine-wide logon
|
||||
autostart (`HKLM\Software\Microsoft\Windows\CurrentVersion\Run\ShopDbEndpointTray`,
|
||||
64-bit view). The installer deliberately does NOT start the tray itself: it runs
|
||||
elevated, so any process it starts inherits an admin token, and mapped drives are
|
||||
per logon token - an elevated tray probes the wrong drive table. The Run key only
|
||||
fires at logon, which would leave the tray dead until sign-out on a machine
|
||||
someone is already using, so the installer also registers a transient
|
||||
`ShopDB tray first launch` scheduled task under `S-1-5-32-545` at `RunLevel
|
||||
Limited`, runs it once, and unregisters it. That task is the only mechanism that
|
||||
can reach into an existing interactive session without carrying the installer's
|
||||
token. Pass `-NoTray` for a headless, service-only install.
|
||||
|
||||
User-context collection does not depend on the tray. The installer registers a
|
||||
`ShopDB user-context probe` scheduled task against the Users group at
|
||||
`RunLevel Limited`, which runs `shopdbagent.exe --collect-usercontext` in the
|
||||
operator's own session at logon and every 30 minutes.
|
||||
|
||||
Right-click the tray icon for:
|
||||
|
||||
@@ -143,7 +154,7 @@ logic itself changes.
|
||||
|
||||
## Diagnostics
|
||||
|
||||
- Rolling file log: `%ProgramData%\ShopDB\EndpointAgent\logs\agent-YYYYMMDD.log`
|
||||
- Rolling file log: `%ProgramData%\ShopDB\EndpointAgent\logs\YYYYMMDD-agent.log`
|
||||
(14-day retention).
|
||||
- Windows Event Log: agent runtime failures and unhandled exceptions are written
|
||||
to the `Application` log under source `ShopDB Endpoint Agent`. The source is
|
||||
|
||||
Reference in New Issue