3703412bafe1ee969643e4229a91fa9404d8fe42
24 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
3703412baf |
Only zero is empty, and the last day is worth reading
Two separate floors were collapsing a live cartridge into a spent one, and removing either alone changes nothing. EMPTY_LEVEL was 5, so everything at or below 5% was assigned daysleft 0 outright. The reasoning was that a printer at 1% is out of toner as far as anyone standing at it is concerned. But the row exists to say how long is left, and 2% draining a point a day has two days in it. Flooring put that cartridge beside ones that genuinely are empty with no way back to the difference. It is 0 now: empty means empty. int(level / rate) then truncated the division, so anything under a full day arrived as 0 whatever the floor did - a cartridge with six hours in it was indistinguishable from one with nothing, and the band read it as empty. daysleft is fractional now, rounded to two places, which is about a quarter of an hour: finer than the estimate deserves, but it costs nothing and keeps the ordering of two nearly-spent cartridges meaningful. daysText reads in whatever unit carries meaning: "6 hours", "1 hour", "29 min", "4 days". Below an hour it goes to minutes with a floor of one, because rounding hours would land back on "empty" - the same bug one rung down. BEHAVIOUR CHANGE worth knowing: a cartridge at 1-5% with NO history used to get daysleft 0 from the floor and land on the order list. A rate needs two readings; with none there is nothing to divide, and the old answer was right by accident - it said "empty" about a level nobody had watched move. It now reports 'no history' and shows under "No estimate yet". This reaches only printers newly added to Zabbix; anything that got to 3% the ordinary way has the history to forecast from. Five existing tests pinned the old rule. They recorded a real decision, so they are rewritten to the new one rather than deleted. One of them was passing for the wrong reason: its series (2.0, 1.7, 1.4, 1.1) drops 0.9, under MIN_DROP_FOR_ESTIMATE, so it never had a rate at all and only passed because the floor short-circuited ahead of the rate check. It now uses a real 20-day drop at a tenth of a point a day and asserts the ten days its docstring always described. The forecast fixture's black cartridge moves from 1% to 0% so the empty band keeps its API-level coverage, and a magenta at 3% covers hours-left end to end. |
||
|
|
b7cfd2b198 |
A supply nobody could read is unknown, not empty
Reported as "CSF04 now reports all 0%", on the printer's own page as well as
the reports. Every supply on one host reading zero at the same instant is not
what a set of cartridges does; it is what a host that stopped answering looks
like.
getsuppliesbyip turned every unreadable item into 0:
try:
level = int(float(item.get("lastvalue", 0)))
except (ValueError, TypeError):
level = 0
An item that has never collected returns lastvalue as an EMPTY STRING, so
float('') raised and the handler substituted zero. lastclock was fetched in the
same request and read by nothing at all, so a reading from three weeks ago was
presented as current.
Zero is a legitimate level meaning spent, which is what made the substitution
dangerous rather than merely wrong. Downstream it reached `level <=
EMPTY_LEVEL`, which set daysleft to 0, which put the printer on the order list:
the report asked purchasing to buy a full set of cartridges for a printer
nobody had measured. On a waste container it was worse - waste is scored as
100 - level, so an unreadable one read as 100% full, the alarm state.
_readlevel now returns (level, lastseen) with level None for no usable reading:
empty, missing or unparseable lastvalue, or a lastclock older than 24h. A
lastclock that is absent is not treated as stale - a reading that cannot be
aged is not thereby wrong, and discarding it would lose real levels. A genuine
"0" is still 0, which is the half that keeps an actually-empty cartridge on the
order list.
classifysupply gains an 'unknown' status with remaining None. It is not
critical: critical is a claim someone acts on, and it may not be made about a
supply nobody measured.
The low-supplies report skips unknown rather than listing it as needing
replacement, and counts it in summary.unknown - a printer that has gone quiet
should be visible as that, not absent and not masquerading as empty.
_annotate_supply reads .get('level') with no 0 default, which would have put
the whole bug back.
PrinterDetail already rendered `level !== null ? ... : 'N/A'`, so it starts
telling the truth as soon as the backend sends null; the UI had been written
for a case the service never produced. It gains the unknown style - muted, not
a severity colour - and a tooltip separating "no reading at all" from "no
reading since <date>", which are different faults with different fixes.
Alerts needed no change: float(None) raises and that loop already continues,
so unknown supplies stop firing low-toner emails as a consequence.
12 of the 16 new tests fail on the old code. The 4 that pass either way pin
that real zeros still behave, which is the regression this fix could cause.
Not verified against CSF04's actual Zabbix data - dev has no reachable Zabbix.
This fixes the mechanism that turns unknown into 0%; /api/printers/<id>/supplies
now distinguishes them, with null for no reading and 0 for a measured zero.
|
||
|
|
f9d298c7f0 |
Name the toner on the forecast, keep the number on the hover
The forecast identified a cartridge by its part number alone. 'W2020X' only tells you which toner it is once you already know, and both places that name a supply - the Order now list and the Part column - showed nothing else, so the report read as a list of codes. Both now show marketingname, which is what the box says: '414X Black'. The part number moves to the title attribute, one hover away, because it is still the thing an order is placed against. A supply with no name on file falls back to the number rather than showing an empty cell; marketingname is nullable. 'Copy list' is deliberately untouched. It writes the part number verbatim, which is what purchasing pastes into an order, and a spec pins that the name does NOT reach that text. firstPart() now returns the whole part row rather than its number, since the cell needs both halves. It has one caller. Dropped the .partnumber style with its .unmapped variant: nothing renders that class any more, and the variant was already dead - the unmapped block lists no part number by definition. Verified by mounting the component against a fixture. The dev box has no Zabbix, so the page itself has no rows to look at there. |
||
|
|
5001aedcf9 |
Offer a spelling on every list, not just the global search
Correction only helped on the global search page, and people search from the list they are already on. Extending it turned out to be a shape question rather than a volume one: thirty routes take a search parameter across a dozen files, so carrying a suggestion in each of their responses is a large change today and one more thing every future plugin author has to remember. So the suggestion moved to ITS OWN ENDPOINT, /api/search/suggest, which any page can call after rendering no rows. A page that has not adopted it shows nothing, which is exactly what it showed before - nothing breaks by omission. The plumbing lives in useListQuery, which already owned the search term, so a list needs three lines: take `suggestion` and `reportCount` from the composable, call reportCount(rows.length) after a fetch, and drop SearchSuggestion into the empty state it already has. A list that never calls reportCount never offers a suggestion. Wired: global search, machines, printers, PCs, network devices, measuring tools, knowledge base, vendors. NOT wired, deliberately: the type and reference lists (machine types, PC types, VLANs, subnets, operating systems and the rest), which are small controlled vocabularies nobody typo-searches, and USB, whose empty state has a different shape and wants doing by hand rather than by pattern. TRAP FOUND WHILE WIRING IT, and left commented in every page: applying a suggestion by calling setSearch alone updates the box and the URL and does NOT reload the list. setSearch only syncs the URL, and the watcher that would reload is suppressed because search.value already holds the new term - the same trap the global search page documents in performSearch. Each page calls its own load function directly. The composable guards a stale answer arriving after a newer search was typed, never offers back the word that was typed, and swallows its own errors: a search that found nothing is already the answer, and failing to improve on it is not worth an error in front of anyone. The route-parity gate caught the new endpoint being served without an entry in docs/api-inventory.json, which is hand-written on purpose; added, and the spec regenerated from it (283 paths, 418 operations). That regeneration also carries the openapi version to 0.12.0, left over from the release. |
||
|
|
875fde9f48 |
Fix what the last round of device fixes broke, and two dips it missed
A review of |
||
|
|
8b9b9363ee |
Toner: count cartridge changes that happened, and rate a burst as one burst
Two things reported from the floor, one cause each. "5 CHANGES IN 90 DAYS, THAT'S HARD TO BELIEVE." It was. A replacement was any +10 rise between readings, with no check on where it landed, so two shapes that are not swaps scored as swaps: a supply reading 0 or near-0 while it was out of the machine and then reading normally again, and a coarse gauge ticking back up after a reseat or a power cycle. A swap must now also LAND near full, because that is what a new cartridge reads, and a single dip that RECOVERS to roughly where it came from is dropped before anything looks at it. The dip filter keys on shape rather than cause, which is why it holds for all of them - a supply pulled out to be shaken, a door open mid-poll, or a site whose preprocessing maps the Printer MIB's unknown sentinels onto 0. It is NOT a Zabbix timeout: an item that does not answer records nothing rather than writing a zero. A genuine near-empty reading before a real swap does not recover, it jumps to full, so it survives and its swap still counts. find_replacements and current_run now read one predicate. When they disagreed, a phantom rise reset the run and threw away the history the estimate needed - so the bad count was quietly damaging the rate as well, which is why both were wrong at once. Expect replacement counts to FALL and per-cartridge history to lengthen. A BURST BIASED THE RATE FOR THE LIFE OF THE CARTRIDGE. The rate was the slope between the first and last reading of the run, and two endpoints cannot tell "steady" from "burst then stopped". A cartridge that lost 20 percent in two days and then barely moved for a month read as 0.83 percent/day forever after, so the report kept promising it would run out long after printing slowed. It is now the median of the per-interval rates: the burst is one interval among many rather than one of two points. Rising intervals are dropped as noise; flat ones stay in at zero, because a cartridge that did not move is real information. If every interval is flat or rising yet the run dropped overall, it falls back to the whole-run slope rather than reporting nothing. Where the intervals disagree by 5x or more the rate carries a marker and an explanation on hover. The number is still the best estimate available; the flag stops it reading as a measurement. The "Changed" column is "Replacements", and its cell says "2 in 90d" rather than "2 / 90d", which was read as a date, a ratio and a version number. |
||
|
|
f34b9ca710 |
Carry the level everywhere a position is drawn, and gate it per occurrence
The hover mini-map said "This asset has a position (2835, 1410) but no level" for every asset in the product. When 0.11.0 gave LocationMapTooltip a levelid prop, NONE of its seven call sites were taught to pass one - printer, machine and PC detail pages, the toner report, enforcement reports, the warranty chip and the dashboard cards - so the component correctly reported a missing level and the preview never drew. Two payloads behind those views also emitted mapx/mapy with no level: the toner report and the enforcement report. The map PDF export had the ORIGINAL bug still in it: it plotted every filtered asset onto the sheet, so exporting the ground floor printed second-floor markers on it. Worse than on screen, because nobody can correct a sheet once it has been printed and carried onto the floor. It now exports only the level being viewed. The legacy import loader sent mapleft/maptop with no level at three call sites. That loader is the one still to run against production, and every marker it created would have been undrawable. It now resolves the site's default level - the legacy schema predates levels and has one floor plan, so that is what its coordinates mean. THE GATE MISSED ALL OF THIS because it asked whether a FILE mentions 'levelid', not whether each position does: one module emitted 'mapx' six times and 'levelid' once and passed. It now checks per occurrence, covers scripts/ as well as shopdb/ and plugins/, and fails any Vue file that binds tooltip coordinates without :levelid. Both new rules were confirmed to fail the build against planted violations before being relied on. Printer QR labels: the asset number is no longer printed. A label now reads name (8201-HPLaserJetPro), QR, FQDN, then IP. The name falls back to the assetnumber because that is where sites actually keep it - every printer here has an empty name field, so preferring the Windows queue name alone would have printed a blank line on every label. |
||
|
|
62f4a42210 |
fix: page past the 100-row cap in batch label sheets and asset pickers
Follow-up to the application-picker fix. Three of these were already wrong on data that exists today, not merely latent. Batch label printing is the worst of them: AssetLabelBatch asked for 500 machines or PCs, got 100, and printed a sheet that looked complete. With 262 machines and 290 PCs in the catalogue that is a physically short run with no error anywhere - the operator finds out at the label printer, or later at the bay with no label on it. PrinterQRBatch, USBLabelBatch and PrintedPartsLabels had the same shape and are fixed alongside it, before their tables cross 100 too. MachineForm's "controls" PC dropdown offered the first 100 of 290, so a machine could not be linked to a PC sorting late in the list. NetworkDeviceForm had it for models, which are already past 100 - and the same file already called modelsApi.listAll() correctly two lines away. Adds listAll() to the machines, computers, printers, network, measuring-tools, USB and printed-parts APIs, all delegating to fetchAllPages(). Still outstanding: callers of vendors, locations, business units and the type catalogues that ask for more than 100. Those tables are all well under the cap today, so they are correct for now and wrong the day they are not. |
||
|
|
3324dbd91e |
Buildings and levels for the floor map, and make every identifier searchable
The map was one picture of one floor. A second floor was added, the blueprint changed size, and machines moved, so a position now records WHICH DRAWING its coordinates belong to. Buildings and levels (ADR-017). Each level owns its blueprint per theme and its own native pixel size; assets.mapx/mapy are pixels of assets.levelid, not of the site. A position whose level is unknown renders "level unknown" and is never drawn on the default level, because a marker on the wrong floor plan looks entirely correct while pointing at the wrong place. Repositioning in bulk: filter by unplaced, needs-review or level, search, place, confirm. Landmark recalibration solves the transform PER AXIS from landmark pairs and never from image dimensions - the canvas grew taller without rescaling, so a dimension-derived scale would stretch Y by 1.57 and be wrong everywhere. It defaults to a dry run, reports what would land off the drawing, snapshots before applying, and clears mapverifiedat because a transform is a guess awaiting review. Snapshots restore, including the level and the review state, and a restore snapshots first so an undo is undoable. Search: gaugelabreference was matched only for measuring tools and maintenancereference was matched nowhere at all, for any asset type, while Settings happily offers both identifiers on machines and PCs. A tag an operator is told to record has to be findable or it is a write-only field. USB devices and printed items were unreachable from search entirely - neither is an asset, so the generic asset search could not see them and no searcher existed; they now match on serial, asset tag, label, bin code and gage-lab tag, honouring isactive, with Settings toggles and result labels to match. The retired-application rule was half a rule: GET /api/knowledgebase hid articles whose topic application is retired while global search still returned them and printed the retired application as the subject. A filter is only real if every path that reaches the row applies it. Contract to 0.20.0 (additive): Asset gained levelid and mapverifiedat, Location gained levelid, and resolve_asset_position returns the levelid belonging to whichever source supplied the coordinates. The five plugins that write a map position are re-pinned. The install-list text format gained levelid as a NINTH field, appended, because the shipped Pascal installer reads fields 0-7 by index. That installer still compiles in one drawing's dimensions and bundles one blueprint, so its map is accurate for the default level only; /api/maplevels is deliberately unauthenticated so it can read both at runtime once rebuilt. Recorded in PRINTER-INSTALLER.md section 6 along with the other known gaps. Migration 7d33 converts an existing single-map site into one building and one default level carrying the old map_* settings, then assigns every placed asset and location to it. Nothing moves on screen. Old settings rows are kept so a rollback still finds them. Verified end to end on MySQL 5.6 from a production-shaped database. |
||
|
|
c648bdf560 |
labels: one module knows how to draw a code, seven views stop guessing
Three core pages and four plugin pages each imported qrcode and jsbarcode directly, and each carried its own answer to the same questions: what margin, what width, which error correction, how big a module must be before a scanner can read it. The answers had already drifted - margin 0 in one place and 2 in another, width 150 against 160 - and on a label that is the difference between a sticker that scans and one that does not. frontend/src/utils/codes.js owns it now: the label-stock presets, the quiet-zone and margin defaults, CODE128 with no printed value, and the printer-resolution arithmetic that only the Tech Tools generator had. A view passes what is specific to its own label and nothing else - MachineBadge still asks for CODE39, because the badge readers predate the shop-floor scanners and decode nothing else, and that is exactly the kind of thing a call site should say out loud. views/print/qrLogo.js is folded in rather than left as a second half-shared helper that only some of the pages reached into. The check script now fails a build that imports either library outside that module. Without it this re-forks within a month: the next label page starts by copying the nearest existing one, which is how it happened the first time. Tests cover the part no amount of looking at a screen verifies - a QR that looks fine at 96 dpi on a monitor can be unreadable at 203 dpi on half-inch stock. |
||
|
|
3d83806135 |
Make the toner forecast an order, not a table
The report answers a purchasing question, and it was answering it in seven columns, two tables and a rowspan. What someone actually needs from it is a short list of what to buy. So it opens with that list, grouped by part number with a quantity. Two cartridges of the same part in different printers is a quantity of two, which is the number an order needs and the one a per-printer table made the reader count by hand. It covers what is empty plus what goes within a fortnight - ordering only what is already empty means running empty. There is a copy button, because it ends up pasted into a mail. Below it the cartridges sit in urgency bands rather than in one long list sorted by a number. The question is which pile a thing is in, and a pile that is empty is worth seeing as empty. Everything past "empty" starts collapsed; the order list above already covers the same ground in a tenth of the height. The row is a cartridge now, not a printer, so it can carry its own part number, its own level bar and its own countdown. Nesting supplies under a printer meant opening a printer to find out whether anything on it needed doing. Cartridges with no part mapped are counted on a single line rather than given one each. They cannot be dropped, since that would quietly shorten the order, and they cannot be ordered from here either - the job they represent is mapping them, which is one job however many there are. Bands and the order horizon are decided server-side, next to the arithmetic that produces them, so a heading cannot disagree with what got added to the list. Checked against a fleet of 43 dev printers with real part mappings, driven by a stub Zabbix - live Zabbix is not reachable from the dev box. |
||
|
|
7d66551622 |
Forecast from the right end of the window, and from the level shown
Four defects stacked into one nonsense report: cartridges at 20% claiming four days, cartridges at 1% claiming weeks. The root cause is a Zabbix API detail. `limit` caps the whole result set rather than each item, and the query sorted ascending, so the cap kept the OLDEST rows in the window. A four-cartridge printer polled every five minutes writes over 100k readings in 90 days; the forecast was fitted to the first few days of that and nothing since. Every rate was real and every rate described a cartridge thrown away three months ago. Nothing in the output looks wrong, which is why it needed pinning in a test rather than a comment. A 90-day burn rate does not need every individual poll, so a long window now reads hourly trends - the table meant for this, a tenth of the rows, and kept longer. Raw history serves short windows and any item a site keeps no trends for. Both are fetched newest-first with the budget scaled per item. Second, the countdown was computed from the last stored reading while the level displayed was the live one, so the two could disagree by a whole cartridge. The live level is now what the countdown divides. A live level far above the stored run means it was swapped since the last reading, and that is reported as a replacement rather than as a collapse in the burn rate. Third, at or below 5% a cartridge reads as empty rather than as a slow drain. At 1% losing a tenth of a point a day the arithmetic says ten days. The printer is out of toner, and it is the first thing to order. Fourth, the days-left column spanned the printer's rows, so the printer's soonest figure was printed beside every supply it had. That alone accounts for the shape of both complaints: a healthy cartridge wearing its neighbour's deadline, and an empty one wearing a number that belonged to nothing on its row. Also fixes float-typed supplies vanishing from any printer that also had an integer-typed one - they live in different history tables and the fetch stopped at whichever answered first. Not verified against live data: Zabbix is not reachable from the dev box. |
||
|
|
d109314123 |
Forecast when a printer runs out, and count what it has been through
The toner report says what is empty now. It could not say what to order, and nothing recorded how fast anything drains - every level read was cached for five minutes and then discarded. Zabbix has been keeping the history all along; we simply never asked. One history.get gives both answers, because a cartridge only goes DOWN while it is in use: a rise is a replacement. Count the rises and you have how many cartridges a printer has been through; fit a slope to the readings SINCE the last rise and you have days-to-empty. Fitting across a replacement averages a spent cartridge with a fresh one and describes neither. Sorted by days left, which is the point. A cartridge at 60% dropping 5% a day needs ordering before one sitting at 8% that has not moved in months, and a level-sorted list ranks those backwards. It refuses to guess. Too few readings, a level that has not moved enough - many printers report in 10% steps and sit on a plateau for a fortnight - or a recent replacement each produce no estimate and say which. Those printers are listed separately rather than sorted in as 0 or as 999, since a printer without an estimate is neither urgent nor safe. Estimates show what they rest on, because "9 days from 21 days of readings" and "9 days from 2 readings" are not the same claim. A separate report card, not an extension of the toner report: that one is an exceptions list a tech acts on today, this is an ordering view read monthly, and the history query is heavier than the live read it would have slowed down. The analysis is pure arithmetic over a list of readings, so the 14 tests cover the noise wobble, the plateau, the swap, junk rows and division by zero without needing Zabbix. Zabbix being unreachable is reported as such rather than rendering an empty table that reads as "nothing is due". |
||
|
|
4d807ccb4b |
toner report: the part to order, and where the printer is
The report exists to answer "what needs replacing and where do I get it", and it was answering neither. The part numbers were already in the lowsupplies payload and simply never rendered; a chip per part now shows them, with capacity tier and page yield on hover, since a model can list several tiers for one colour. Asset # and Location columns are gone. Location is replaced by the floor-plan preview the asset pages already use, hung off the printer name via its mapx/mapy. The IP is now the site's FQDN (printer_hostname_template, built from the IP exactly as PrinterForm does) and links to the printer's own web page in a new tab - the report is a worklist, and losing your place in it to visit one printer means finding your row again. The raw IP stays on hover. Cartridge names were ellipsised inside a fixed 120px column, hiding the one thing being reordered. The supplies cell is a grid with a max-content name column, so names show in full and still line up across a printer's rows. CSV and emailed exports follow the screen, with one row per part number so the result is a copy-pasteable order list. |
||
|
|
d8fe0a48b2 |
Stop a stray click outside a modal discarding what was typed
Operators reported losing a part-filled form by clicking slightly outside it. Every data-entry modal closed on a backdrop click with no warning and no way back - the worst possible response to a misplaced click, and it happens most to someone adding their first records at a new site. Close-on-overlay is removed from 35 modals across 30 files: anything containing an input, textarea, select or v-model. They still close by Cancel or the X. Confirmation dialogs keep it, because a delete prompt holds nothing to lose and dismissing one by clicking away is the behaviour people expect. VendorsList shows the distinction - its edit form no longer closes that way, its delete confirmation still does. The shared Modal component now defaults closeOnOverlay to FALSE. Every current caller holds a form, a checkout, a stock adjustment or a map position being picked, and not one passed the prop, so all of them had the same fault. A modal that genuinely wants dismissing that way opts in explicitly. Also regroups the operator console menu, which had grown to numbers 1-9 plus three letters bolted on with no order to them. Actions are now grouped by what they touch, keyed by their first letter, and the old numbers still work so nobody who has used it for months is stopped by a rearrangement. The menu also warns when the server is not fully provisioned and names the key that fixes it, instead of reporting it as ordinary status lines that read as normal unless you already knew what to look for. That check is cached for the session because it shells out to flask twice and the answer does not change while somebody reads the screen. |
||
|
|
cb18d170cf |
Say whose type it is
Two fields on the same page were both labelled "Type": the asset's own, and the catalog model's. Only one of them was vague. "Model type" already says exactly what it is; the bare "Type" did not say whose. So the unqualified one is the one that changes. No new vocabulary, and "Model type" reads correctly against it: Type -> Machine Type (machines) Type -> PC Type (computers) Type -> Printer Type (printers) Type -> Device Type (network devices) Left alone everywhere the word is not ambiguous - measuring tools, subnets, VLANs, notifications, supply types and the manifest editor have no model type on screen to be confused with. This is a labelling change only. It does not address the blank type column on machines imported from the classic ASP database, which is a data gap the backfill script fills; renaming a column heading was never going to put values in it. |
||
|
|
24266146d8 |
Show the model's type only when it differs from the asset's own
Adding a "Model type" row next to "Type" put two rows in the Hardware section that read identically. They come from different tables - modeltypes is the catalog-wide list spanning every kind of asset, machinetypes is machine-only - but the names line up in practice: all 262 machines in the development database match exactly, which is the same fact that makes the type backfill safe. So the row now appears only when the two disagree, which is the case worth seeing: a model catalogued as one thing fitted to an asset recorded as another. When they agree it says nothing and is hidden. Applied to machines, PCs, printers and network devices, each compared against its own type table. |
||
|
|
3f320fcc8b |
Derive an asset's vendor from its catalog model, and show the model's own type
An asset that carries a model but no vendor was showing a blank the database could already answer: the model records its vendor, and both sides reference the same vendors table. Machines, PCs, printers and network devices now fall back to it. The fallback is FLAGGED, not merged silently. to_dict sets vendorfrommodel and the detail pages render "(from model)" beside the value, because the record itself is still empty: the edit form shows an empty vendor box, and a page implying the vendor is stored would be lying about where it came from. The model's type is exposed under its own name, modeltypename, and shown as a separate "Model type" row. It is deliberately NOT used to fill in the asset's own type. modeltypes is the catalog-wide list covering every kind of asset - it holds "Access Point", "Camera" and "Desktop PC" alongside the machine entries - so it is a different taxonomy from machinetypes. Only about two thirds of the names overlap, and mapping one onto the other would mistype the remainder, with the failure mode being a machine labelled "Desktop PC". scripts/backfill_vendor_from_model.py writes the derived vendor down for real, since the display fallback leaves reports that read vendorid still seeing nothing. It is a dry run unless given --commit, fills only rows where the asset's vendor is NULL and the model names one, and never overwrites a vendor somebody chose. It skips a table lacking either column, so it runs against a server whose network migration has not been applied yet. Verified against the development database by nulling one machine's vendor inside a transaction: it was detected as fillable, restored to exactly its original value, and the rollback left the row untouched. FLASK_ENV is not forced by the script. The app already reads it from .env, and overriding it demanded a SECRET_KEY the environment had no reason to supply. |
||
|
|
0d40780f53 |
printers: printer installer map + install-batch endpoint
Rebuilds the classic printer-installer feature: pick printers on the shopfloor map, download a .bat that installs them. Backend (asset_routes.py): GET /api/printers/install-batch?printerids=1,2,3 returns a .bat attachment. Groups printers the way the classic installprinter.asp did - HP/Xerox via the universal PrinterInstaller.exe /PRINTER="a,b,c", printers with a .exe installpath via that installer /SILENT, and anything else (no installpath, or a .zip) listed for manual install instead of being run blindly. Download URLs derive from the site_base_url setting + the IIS-served /installers folder (no hardcoded host). Reuses the existing install-list query shape. Frontend: PrinterInstallerMap.vue - full-screen Leaflet shopfloor map (reuses mapConfig), a marker per network printer at its mapx/mapy, click to toggle-select, sidebar with the selection + an Install button that downloads the batch. Toplevel route /printer-installer, printersApi.installList(), and an Installer Map button on the printers list. Tests: install-batch grouping (universal/specific/manual) + requires-ids. |
||
|
|
b63690996a |
fix: location dropdowns rendered blank (wrong field) + require printer model
The location option label read l.location, but the Location.to_dict() field is locationname, so every option rendered blank - the dropdown looked empty and "massive" (a long list of blank rows). Fixed across all five affected forms: printers, computers, network devices, network device form, and the subnets location filter. Other .location uses (printer-driver URL, search-result label, report bylocation key) are legitimately different fields, left alone. Also require a model on the printer form: asterisk + required attr, plus a JS guard in savePrinter (the native required is skipped while the select is disabled with no vendor picked) that points the user at the vendor first. |
||
|
|
b211e817d5 |
printers: low-toner alerts with configurable thresholds + support-team routing
Poll Zabbix for toner levels on a schedule and email/webhook on a downward crossing. Warning fires at or below the warning threshold (default 5%), critical at the critical threshold (default 0%); both thresholds are settings. State lives in printersupplyalerts so an alert fires once per crossing and re-arms after a refill. Recipients mirror the printedparts pattern: plugin-scoped shopdb users + roles + free-text emails (falling back to the site alert_recipients), and a chosen support team's webhook (falling back to the site alert_webhook_url). - PrinterSupplyAlert model + migration printers0002supplyalerts - alerttier(remaining, warning, critical) + check_supplies poller - flask printers check-toner-alerts CLI (run via scheduled task/cron) - printers alert settings + Low-Toner Alerts settings page - 7 tests: tier boundaries, once-per-crossing + re-arm, toner-only scope, custom thresholds, support-team webhook routing |
||
|
|
31139267d1 |
Fix model images 404 under a subpath mount (withBase)
Model image URLs are root-relative (/api/models/image/...), so on an /ops subpath deploy the raw <img src> resolved to the server root and 404'd. Wrap every model-image src in withBase(): machine/printer/PC/network detail heroes, the models settings preview, and the machine-badge / asset-label print pages. withBase leaves external http(s)/data URLs untouched. |
||
|
|
592ff49abe |
ADR-013 Phase 4: extract the 11 plugin routes embedded in core.js
core.js still routed plugin-owned pages directly. Extracted all 11 into the owning plugin's route file + moved their views into plugins/<name>/frontend/: - computers: reports/pc-relationships, settings/pctypemapping - printers: reports/toner, settings/printertypes, settings/zabbix (toner/supply monitoring) - machines: settings/machinetypes - network: settings/networktypes - warranty: settings/dellwarranty - slides: settings/slides (its route file gains a default export; it was toplevel-only) - employees: NEW plugin frontend (employees/:sso + settings/employeedirectory) - employees had no route file before; its pages lived only in core.js. core.js now holds only core routes; all 14 bundled plugins are self-contained under plugins/<name>/frontend/. Verified live: the extracted Machine Types settings page renders in the settings rail from the machines plugin frontend. Build + 58 vitest + naming green. |
||
|
|
ebca0b00b0 |
ADR-013 Phase 4: relocate the remaining 9 plugin frontends (all 13 done)
Relocate warranty, measuringtools, network, printers, usb, notifications, computers, and slides into plugins/<name>/frontend/. Each plugin's views are pulled from wherever they lived (own dir, plus the shared views/settings/, views/reports/, views/print/ dirs, and top-level views) into the plugin's frontend/views/, and its route file becomes the self-contained routes.js. Handled the messy cases: - computers: name mismatch (its views live in views/pcs/) - moved by following the route file's own imports, so the dir name did not matter. Its OS/access- protocol/PC-type settings views move with it (only computers.js routed them). - network: NetworkHub's sibling sub-views (NetworkDevicesList, SubnetsBrowse, not directly routed) moved too so its `./` imports resolve. - printers: the qrLogo helper is SHARED with core AssetLabel, so it stays in views/print/ and PrinterQR imports it via @/views/print/qrLogo. - slides: route file is toplevel-only (TVDashboard); SlideManager stays core (core.js routes /settings/slides). frontend/src/views/ now holds only core views; frontend/src/router/routes/ holds only core.js. All 13 plugins are self-contained under plugins/<name>/frontend/. Verified live: Network (hub + moved sub-views), Computers (name mismatch), GE-Enforce (helper), printedparts all render from their staged frontends. Build + 58 vitest + naming green. |