The device token assumes a handful of fixed screens an administrator
provisions once. That is not how these kiosks are used: most people open the
page on their own PC, and there is no login, so per-browser provisioning would
mean touching every PC on the floor and losing it again on the next reimage or
cleared profile. A screen in that state did not look refused either - the USB
kiosk rendered a working page whose every call answered 404.
Both kiosks now admit a caller on either ground, the same shape the GE-Enforce
client endpoints already use: the per-device token, or a source address inside
an allowlist. Wall screens keep the token and are not confined to the
allowlist; everyone else is admitted by where they are on the network. Still
gated on the site's enable flag, so nothing opens by itself, and both
allowlists ship empty - token-only until a site enters its ranges.
- shopdb.api gains ip_in_cidrs and request_ip_allowlisted (contract 0.35.0).
On the surface because both plugins need the identical gate, and a CIDR
parser copied into two of them is where a fail-open creeps in later. They
fail closed on an empty setting, an unparseable caller address and a
malformed entry, and they read remote_addr rather than raw X-Forwarded-For -
so the IIS rewrite rule is what makes them meaningful, which the module says
at length.
- Separate settings per kiosk, usb_kiosk_allowed_cidrs and
printedparts_kiosk_allowed_cidrs. One must not grant the other, for the same
reason the tokens are separate.
- Both settings pages get a picker listing the network plugin's subnets with
their VLANs. It stores resolved CIDR strings, not subnet ids: the setting has
to work at a site that does not run that plugin and must not break when an
inventory row is deleted. Entries matching no subnet are shown rather than
hidden, since a stale one left by an inventory edit looks exactly like a
hand-typed range.
- USBKiosk says it was not admitted instead of pretending to work, which
PartsKiosk already did.
- The USB settings page keyed text-vs-boolean off the token alone. Adding a
second text setting to the boolean path would have saved it as the word
'true' - the bug that replaced the kiosk token and 404'd every provisioned
screen. Both load and save now key off a list, with a spec on it.
The trade, stated plainly in the admin UI: anyone on an allowed network can
check a drive in or out against a badge number they guess, and the record
carries that person's name. Badges are attribution, not authorization. Keeping
the ranges narrow is what bounds it; login is the alternative and was ruled out
because these users do not sign in.
The page saved every field as 'true'/'false', the kiosk device token
included, and loaded the token as a boolean. One save of Settings > USB
Devices therefore stored the literal word "true" (or "false") as the token,
and every kiosk provisioned with the real token got 404 on each request -
reported as the kiosk no longer accepting an SSO. Generate + Save never
stored the generated value either.
The token now loads and saves as text. The server already keeps the stored
token when it receives the mask back unchanged. The two switches still save
as booleans. The parts kiosk page was not affected.