Let the server decide which NIC is a PC's address, and keep the rest
A CMM reported 100.0.0.1 as its address and never reported 10.48.255.210 at
all. Both halves of that were the same mistake.

THE BAY WAS CHOOSING. The collector schema took a single `ipaddress`, so the
script picked one NIC and dropped the others - preferring an address inside a
configured range, else whichever interface carried a default route. A bay
cannot make that judgement: it does not know the site's addressing. On this
CMM the Marvell AQtion 10Gbit link to its controller is a real hardware NIC,
up, and carries a default route of its own, so it satisfied every test the
script had. It won, and the corporate address was discarded before the request
was even built - which is why it is not in ShopDB even as a second row.

So the bay now reports EVERY connected hardware NIC with a routable IPv4, and
takes no view. The server picks the primary from collector_corporate_ranges, a
new per-site setting, and writes a Communication row for each of the others.
Naming the ranges is what turns the answer from a guess into a decision; with
none set it still falls back to the default-route flag and then to the first
reported, both guesses, both better than before only because nothing is thrown
away now.

Rows are keyed on the MAC where the bay sends one, because an address moves
between adapters and a MAC does not. A NIC that is down at check-in is left
alone rather than deleted - being down is not evidence the record is wrong,
and hand-entered gateway, DNS and serial settings live on those same rows.
Exactly one row ends up flagged primary, and only a row this report touched
can claim it, so a check-in cannot silently demote an address set by hand.

-AllowedRanges and the CollectorRanges registry value are now accepted and
ignored, logging a line that says where the setting moved. The parameter stays
because a scheduled task still passing it would otherwise fail on an unknown
argument.

A bay on an older collector sends one address and no interfaces; that keeps
working and is pinned by a test.

Scope: product
2026-08-31 17:40:21 -04:00

340 lines
15 KiB
PowerShell

# Report-AssetToShopDB.ps1
#
# Reports a PC's identity to ShopDB (Flask) so the computers/machines record
# stays current with whatever the PC actually is right now: hostname, BIOS
# serial, pc-type, logged-in user, DNC machine number (2001, 2002, ... when
# present) and its corp/AESFMA IPv4 address.
#
# TARGET: the ADR-006 collector API.
# POST <shopdb>/api/collector/computers
# The server is NOT baked in. It comes from HKLM:\SOFTWARE\GE\ShopDB BaseUrl,
# which Install-GEEnforce.ps1 provisions and the enforcement client already
# needs, or from -ApiUrl in the manifest entry's Args. ADR-015: a site name in
# product code is a defect, and this script ships to every site.
# The computers plugin's apply_collector_payload upserts idempotently by
# hostname (create if missing, patch-style update if present - only the fields
# posted here change, so it never clobbers model/VNC/WinRM). Machine number maps
# to Asset.assetnumber; the placeholder 9999 is skipped server-side.
#
# AUTH: the collector API does NOT honor the GE-Enforce IP allowlist (that only
# covers the geenforce fetch/report endpoints). It needs a collector.ingest key,
# sent as the X-API-Key header. The key is read from HKLM:\SOFTWARE\GE\ShopDB
# CollectorKey (same secret store the GE-Enforce client uses; provisioned at
# imaging), or overridden via the manifest entry's Args -ApiKey. Never bake the
# key into the manifest JSON on the share.
#
# Deployed in common\ (runs on EVERY shopfloor pc-type). Non-DNC bays report
# identity with no machineNo, so no PC-to-machine link is built - by design.
# Runs every GE-Enforce cycle as a Type=PS1 / DetectionMethod=Always entry under
# the SYSTEM task. Always exits 0 so "last run result" stays clean; failures are
# logged, never thrown.
#
# WHY ONE NIC ONLY:
# Some bays carry two NICs - a private controller NIC and the routable
# corporate NIC. This script reports ALL of them and lets the server decide
# which is the PC's address, from the collector_corporate_ranges setting.
# Choosing here was wrong: a bay cannot know a site's addressing, and a CMM
# whose 10Gbit controller link carries a default route reported the
# machine-side address as the PC's - with the corporate one never sent.
param(
# Flask collector endpoint for the computers plugin. Empty resolves from
# HKLM:\SOFTWARE\GE\ShopDB BaseUrl; override here if the path ever moves.
[string]$ApiUrl = '',
# Comma-separated CIDRs naming this site's routable ranges, e.g.
# '10.20.0.0/23,10.21.4.0/26'. Empty uses the default-route NIC instead.
[string]$AllowedRanges = '',
# collector.ingest key (X-API-Key). Default: read from the GE-Enforce secret
# store in the registry. Override with -ApiKey via Args for testing.
[string]$ApiKey = '',
[int]$TimeoutSec = 30
)
$ErrorActionPreference = 'Continue'
# Force TLS 1.2 - older images default to SystemDefault which may negotiate a
# protocol the site rejects; the collector POST is HTTPS.
[Net.ServicePointManager]::SecurityProtocol = [Net.SecurityProtocolType]::Tls12
$logDir = 'C:\Logs\Shopfloor'
if (-not (Test-Path $logDir)) {
New-Item -ItemType Directory -Path $logDir -Force -ErrorAction SilentlyContinue | Out-Null
}
$logFile = Join-Path $logDir ('report-asset-{0}.log' -f (Get-Date -Format 'yyyyMMdd'))
function Log([string]$msg) {
$ts = Get-Date -Format 'yyyy-MM-dd HH:mm:ss'
"$ts $msg" | Tee-Object -FilePath $logFile -Append | Out-Null
}
# Server from the GE-Enforce config hive when not passed via Args. Any site
# running this script is running the enforcement client, which cannot work
# without BaseUrl, so it is present wherever this is deployed.
if (-not $ApiUrl) {
foreach ($regPath in @('HKLM:\SOFTWARE\GE\ShopDB', 'HKLM:\SOFTWARE\WOW6432Node\GE\ShopDB')) {
try {
if (Test-Path $regPath) {
$base = [string](Get-ItemProperty -Path $regPath -Name BaseUrl -ErrorAction Stop).BaseUrl
if ($base -and $base.Trim()) {
$ApiUrl = $base.Trim().TrimEnd('/') + '/api/collector/computers'
break
}
}
} catch {}
}
}
if (-not $ApiUrl) {
Log 'ERROR no ShopDB URL (HKLM:\SOFTWARE\GE\ShopDB BaseUrl or -ApiUrl). Skipping.'
exit 0
}
# collector key from the GE-Enforce secret store when not passed via Args.
if (-not $ApiKey) {
foreach ($regPath in @('HKLM:\SOFTWARE\GE\ShopDB', 'HKLM:\SOFTWARE\WOW6432Node\GE\ShopDB')) {
try {
if (Test-Path $regPath) {
$v = [string](Get-ItemProperty -Path $regPath -Name CollectorKey -ErrorAction Stop).CollectorKey
if ($v -and $v.Trim()) { $ApiKey = $v.Trim(); break }
}
} catch {}
}
}
if (-not $ApiKey) {
Log 'ERROR no collector key (HKLM:\SOFTWARE\GE\ShopDB CollectorKey or -ApiKey). Skipping.'
exit 0
}
# -AllowedRanges and the CollectorRanges registry value are ACCEPTED AND
# IGNORED. Deciding which NIC is the PC's address moved to the server, where
# the site's addressing actually lives: this script now reports every NIC and
# takes no view. The parameter stays so a scheduled task still passing it does
# not fail on an unknown argument.
if ($AllowedRanges) {
Log 'NOTE -AllowedRanges is ignored; set collector_corporate_ranges in ShopDB settings instead.'
}
Log '=== Report asset to ShopDB (collector) ==='
# hostname - the collector identity field. required.
$hostname = $env:COMPUTERNAME
# BIOS serial - optional now (collector keys on hostname). Sent when present.
$serialNumber = ''
try {
$serialNumber = (Get-CimInstance -ClassName Win32_BIOS -ErrorAction Stop).SerialNumber
if ($serialNumber) { $serialNumber = $serialNumber.Trim() }
} catch {
Log "WARN could not read BIOS serial: $($_.Exception.Message)"
}
# Machine identifier - optional, sent only if found. Maps to Asset.assetnumber
# server-side (9999 placeholder skipped there and here).
# 1. eDNC registry (WOW6432Node, then native) - DNC/collections bays (2001...).
# 2. C:\Enrollment\cmm\cmmid.txt - CMM bay id (e.g. CMM3).
# 3. C:\Enrollment\machine-number.txt - imaging value.
# keyence / genspect / part-marker have no per-bay id -> no machineNo sent.
# Those bays name their DEVICE instead, in asset-id.txt below.
$machineNo = ''
foreach ($regPath in @(
'HKLM:\SOFTWARE\WOW6432Node\GE Aircraft Engines\DNC\General',
'HKLM:\SOFTWARE\GE Aircraft Engines\DNC\General'
)) {
if ($machineNo) { break }
try {
if (Test-Path $regPath) {
$v = [string](Get-ItemProperty -Path $regPath -Name MachineNo -ErrorAction Stop).MachineNo
if ($v -and $v.Trim() -ne '9999') { $machineNo = $v.Trim() }
}
} catch {
Log "WARN could not read MachineNo from ${regPath}: $($_.Exception.Message)"
}
}
if (-not $machineNo) {
$cmmFile = 'C:\Enrollment\cmm\cmmid.txt'
if (Test-Path -LiteralPath $cmmFile) {
try {
$v = ([string](Get-Content -LiteralPath $cmmFile -First 1 -ErrorAction Stop)).Trim()
if ($v -and $v -ne '9999') { $machineNo = $v; Log "machineNo from $cmmFile (CMM bay id): $machineNo" }
} catch { Log "WARN could not read ${cmmFile}: $($_.Exception.Message)" }
}
}
if (-not $machineNo) {
$mnFile = 'C:\Enrollment\machine-number.txt'
if (Test-Path -LiteralPath $mnFile) {
try {
$v = ([string](Get-Content -LiteralPath $mnFile -First 1 -ErrorAction Stop)).Trim()
if ($v -and $v -ne '9999') { $machineNo = $v; Log "machineNo from $mnFile (imaging value): $machineNo" }
} catch { Log "WARN could not read ${mnFile}: $($_.Exception.Message)" }
}
}
# OS name string (caption + feature-update + build), e.g.
# "Microsoft Windows 11 Enterprise 23H2 (build 22631)". Server upserts each
# distinct string into operatingsystems.
$osVersion = ''
$lastBootTime = ''
try {
$os = Get-CimInstance -ClassName Win32_OperatingSystem -ErrorAction Stop
$osVersion = "$($os.Caption)".Trim()
$displayVersion = ''
try {
$displayVersion = (Get-ItemProperty 'HKLM:\SOFTWARE\Microsoft\Windows NT\CurrentVersion' -Name DisplayVersion -ErrorAction Stop).DisplayVersion
} catch {}
if ($displayVersion) { $osVersion += " $displayVersion" }
if ($os.BuildNumber) { $osVersion += " (build $($os.BuildNumber))" }
$osVersion = $osVersion.Trim()
# ISO 8601 - collector parses via datetime.fromisoformat.
try { $lastBootTime = $os.LastBootUpTime.ToString('yyyy-MM-ddTHH:mm:ss') } catch {}
} catch {}
# interactive console user. runs as SYSTEM, so use Win32_ComputerSystem.UserName
# (console session owner). empty when nobody logged on -> omitted so an
# unattended bay does not blank the last-known user.
$loggedInUser = ''
try {
$loggedInUser = (Get-CimInstance -ClassName Win32_ComputerSystem -ErrorAction Stop).UserName
if ($loggedInUser) { $loggedInUser = ($loggedInUser -split '\\')[-1].Trim() }
} catch {
Log "WARN could not read logged-in user: $($_.Exception.Message)"
}
# The DEVICE hanging off this PC - the ONE enrollment file for every bay that
# has no NTLARS/eDNC MachineNo registry to identify it. It names the asset and
# nothing else: it does not say what kind of device that is, because the pc-type
# already does, so the same file serves a part marker, a Keyence, a Genspect or
# anything added later without a new file or a client change.
#
# Deliberately NOT machine-number.txt. machinenumber answers "which bay is
# this" and is what GE-Enforce TargetMachineNumbers gates on, so naming a device
# there would silently stop every bay-gated manifest entry from matching.
#
# WHY A FILE AT ALL: every other identity the server can fall back to is derived
# from the PC - a prior link from this PC, or an asset number built from this
# hostname - so none of them survive a PC SWAP. The replacement box mints a
# SECOND record for the same physical device while the first keeps its history
# under a dead PC's name. This file is what survives.
#
# The server ADOPTS the named asset, refuses a value it cannot resolve, and
# refuses one that resolves to the wrong kind of thing - so a typo warns instead
# of inventing a phantom device.
$deviceId = ''
$idFile = 'C:\Enrollment\asset-id.txt'
if (Test-Path -LiteralPath $idFile) {
try {
$deviceId = ([string](Get-Content -LiteralPath $idFile -First 1 -ErrorAction Stop)).Trim()
if ($deviceId) { Log "deviceId from ${idFile}: $deviceId" }
} catch { Log "WARN could not read ${idFile}: $($_.Exception.Message)" }
}
# 0.12.0 shipped measuringtool-id.txt before the file was generalised. Read it
# as a fallback so a bay already staged with one keeps reporting.
if (-not $deviceId) {
$mtFile = 'C:\Enrollment\measuringtool-id.txt'
if (Test-Path -LiteralPath $mtFile) {
try {
$deviceId = ([string](Get-Content -LiteralPath $mtFile -First 1 -ErrorAction Stop)).Trim()
if ($deviceId) { Log "deviceId from ${mtFile} (pre-0.13 name): $deviceId" }
} catch { Log "WARN could not read ${mtFile}: $($_.Exception.Message)" }
}
}
# imaging pc-type (gea-shopfloor-*), read from the enrollment file. Sent only
# when present; absent -> server leaves existing pctype untouched (a bare report
# never re-types a PC). Unmapped values return a warning, not an error.
$pcType = ''
$ptFile = 'C:\Enrollment\pc-type.txt'
if (Test-Path -LiteralPath $ptFile) {
try {
$pcType = (Get-Content -LiteralPath $ptFile -First 1 -ErrorAction Stop).Trim()
} catch { Log "WARN could not read ${ptFile}: $($_.Exception.Message)" }
}
# PC make/model from WMI. Server resolves/creates vendor + model. Sent only when
# present so a WMI read failure does not blank the model.
$manufacturer = ''
$model = ''
try {
$cs = Get-CimInstance -ClassName Win32_ComputerSystem -ErrorAction Stop
$manufacturer = "$($cs.Manufacturer)".Trim()
$model = "$($cs.Model)".Trim()
} catch {
Log "WARN could not read make/model: $($_.Exception.Message)"
}
# EVERY connected hardware NIC with a routable IPv4, and no opinion about
# which one matters. Choosing used to happen here and this was the wrong place
# for it: a bay cannot know a site's addressing. A CMM whose Marvell AQtion
# 10Gbit link to its controller sits on 100.0.0.1 reported THAT as the PC's
# address - the link carries a default route too - and the corporate address
# was never sent at all, so ShopDB could not even show it as a second row.
#
# The server picks the primary now, from the site's configured corporate
# ranges, and records the rest. Report what is here; let it decide.
$interfaces = @()
$defaultRouteIfIndexes = @()
try {
$defaultRouteIfIndexes = @(Get-NetRoute -DestinationPrefix '0.0.0.0/0' -ErrorAction Stop |
Select-Object -ExpandProperty InterfaceIndex -Unique)
} catch {
Log "WARN could not read the route table: $($_.Exception.Message)"
}
try {
$ipObjs = Get-NetIPAddress -AddressFamily IPv4 -ErrorAction Stop |
Where-Object { $_.IPAddress -notmatch '^169\.254' -and $_.IPAddress -ne '127.0.0.1' }
foreach ($ipo in $ipObjs) {
$adapter = $null
try { $adapter = Get-NetAdapter -InterfaceIndex $ipo.InterfaceIndex -ErrorAction Stop } catch {}
if (-not $adapter) { continue }
if (-not $adapter.HardwareInterface) { continue }
if ($adapter.Status -ne 'Up') { continue }
$interfaces += @{
ipaddress = $ipo.IPAddress
macaddress = $adapter.MacAddress
adaptername = $adapter.InterfaceDescription
isdefaultroute = [bool]($defaultRouteIfIndexes -contains $ipo.InterfaceIndex)
}
}
} catch {
Log "WARN interface enumeration failed: $($_.Exception.Message)"
}
if ($interfaces.Count -eq 0) {
Log 'WARN no routable IPv4 NIC found; posting identity without any interface.'
} else {
Log ("Reporting {0} NIC(s): {1}" -f $interfaces.Count,
(($interfaces | ForEach-Object { $_.ipaddress }) -join ', '))
}
# collector schema fields (lowercase concatenated). hostname is required; the
# rest are sent only when present so a partial read never blanks a good value.
$body = @{ hostname = $hostname }
if ($serialNumber) { $body['serialnumber'] = $serialNumber }
if ($machineNo) { $body['machinenumber'] = $machineNo }
if ($pcType) { $body['pctype'] = $pcType }
if ($deviceId) { $body['deviceid'] = $deviceId }
if ($manufacturer) { $body['vendorname'] = $manufacturer }
if ($model) { $body['modelnumber'] = $model }
if ($osVersion) { $body['osname'] = $osVersion }
if ($lastBootTime) { $body['lastboottime'] = $lastBootTime }
if ($loggedInUser) { $body['loggedinuser'] = $loggedInUser }
if ($interfaces.Count -gt 0) { $body['interfaces'] = $interfaces }
$body['lastcheckin'] = (Get-Date).ToUniversalTime().ToString('yyyy-MM-ddTHH:mm:ss')
$json = $body | ConvertTo-Json -Compress -Depth 4
Log ("POST {0} host={1} serial={2} pcType={3} make={4} model={5} os={6} boot={7} machineNo={8} user={9} ip={10} deviceId={11}" -f `
$ApiUrl, $hostname, $serialNumber, $pcType, $manufacturer, $model, $osVersion, $lastBootTime, $machineNo, $loggedInUser, $corpIp, $deviceId)
try {
$resp = Invoke-RestMethod -Uri $ApiUrl -Method Post -Body $json `
-ContentType 'application/json' `
-Headers @{ 'X-API-Key' = $ApiKey } `
-TimeoutSec $TimeoutSec -ErrorAction Stop
Log ("RESPONSE {0}" -f ($resp | ConvertTo-Json -Compress -Depth 4))
} catch {
Log "ERROR POST failed: $($_.Exception.Message)"
}
exit 0