main was 16 days and 259 commits behind the line the product is actually built on, at contract 0.30.0 against 0.35.0, with no per-PC credential code at all. It was neither current nor curated - just stale. This brings it forward and, at the same time, makes it mean something: main is what a receiving site installs, and nothing else. WHAT IT CARRIES. Twelve plugins - backups, computers, endpoints, guides, knowledgebase, machines, network, notifications, printers, slides, tools, warranty - plus applications, which is manifest-less core and always ships. The only manifest dependency inside that set is endpoints on computers, and both are in it, so the closure is self-contained. WHAT IT DOES NOT. employees, geenforce, measuringtools, printedparts and usb stay on the site line. So do the Windows installer tree, the VM rehearsal helpers, the agent tooling config, one site's data loader, the internal audit and findings records, and the planner spreadsheet. 1,135 tracked files against 1,438. A REMOVAL THAT BREAKS THE APP IS NOT A REMOVAL, and two nearly shipped: deploy/site-profile-universal.json still named all seventeen plugins. It is the file docs/DEPLOY.md tells a site to provision from, so a fresh install would have failed at `flask plugin apply-profile` with PluginError - the first thing a receiving site does, broken by the branch meant to serve them. It now names the twelve that exist, and its comment says the two must agree. agent/ was never refreshed. Whoever populated this branch copied shopdb/, plugins/, frontend/ and tests/ from the site line and left the agent tree at its September state: 22 C# and PowerShell sources missing, including AgentCredentials, EnrollmentService, AgentHttpFactory and the fleet-alert client, plus one file the site line had deleted still present. The old tree is internally consistent, so it compiles, and nothing in CI builds it - every gate was green over a server that speaks enrollment and per-PC credentials to a bundled agent source that cannot. Resynced whole. DECISIONS THIS ENCODES, rather than defers: - The plugin-authoring lab builds printedparts, whose manifest depends on employees, so it could not stay. The lab remains on the site line and main ships no build-along tutorial. That is a real loss for an adopting developer and is recorded here rather than discovered later. - Recognition, Training and Recertification notifications are no longer seeded. Each splits one notification into a card per employee and renders a photo, which needs a plugin this branch does not bundle. Seeding them would offer an author a type that cannot resolve anybody. A site that installs employees gets them from that plugin's own seed. - Windows/IIS is documented as the legacy path throughout, and the README leads with Docker, because that is what a receiving site gets. The API description is regenerated for THIS branch - 347 paths and 483 operations, down from 415 and 573 - so the published contract describes what is here rather than what the site line serves. docs/CONFIG.md lost the two measuring-tool label keys the code no longer declares, which two lanes had decided opposite ways. Suite: 3124 passed, 6 skipped. Naming and style gates pass. The docs gates run rather than skip, and every index line count is derived from the file it names.
6.1 KiB
ADR-018: Metrology instruments are machines
- Status: ACCEPTED
- Date: 2026-09-04
- Deciders: ShopDB maintainers
- Relates to: ADR-001 (asset as the platform contract), ADR-006 (collector contract), ADR-008 (a plugin owns its tables and its migration chain)
- Supersedes: ADR-005 (equipment plugin scope vs measuringtools plugin)
Context
ADR-005 split manufacturing machinery from metrology instruments into two
plugins on the grounds that they are two asset classes: machines make parts,
measuring tools measure them. It named the metrology population as "CMMs,
Keyence vision systems, wax-and-trace surface profilometers, GenSpec
instruments", and the measuringtools plugin was built against a docstring
naming a different population again: "calipers, micrometers, thread gages,
bore gages, height gages".
Those two lists are not the same thing, and the difference is the whole decision. One is bay-mounted capital equipment with a controlling PC. The other is hand tools in a drawer. The plugin was built for the second and populated with neither.
Sixteen months on, the evidence is in:
measuringtoolsholds zero rows, against 204 machines, 305 computers, 73 network devices and 53 printers.- The metrology inventory actually waiting to be entered is 134 instruments: 35 CMM, 32 form tracer, 23 vision, 18 wax trace, 14 measuring, 8 Genspect, 2 eddy current, 1 spline. Every one is bay-mounted with a controlling PC.
- Not one caliper, micrometer, thread gage, bore gage or height gage. The population the plugin's own docstring justifies it with does not exist at the reference site and is not planned.
CMMalready exists as amachinetype, andPart Markeris already classed as a machine whileForm Traceris classed as a measuring tool. Two bay instruments with a controlling PC, split across two plugins, with the line drawn somewhere no operator can predict.
The split has therefore been paying an ongoing cost - a duplicate type page, a
settings group, a nav section, a migration chain, a searcher, dashboard cards,
map colours, label printing and four collector pctypemap entries - to model a
distinction that the inventory does not make.
Decision
Metrology and inspection instruments are machines. The measuringtools plugin
is retired and the measuring_tool asset type is removed.
Calibration moves to machines, and is not lost
machines gains the calibration lifecycle as nullable columns:
machines
- calibrationintervaldays integer, null
- lastcalibrationdate date, null
- nextcalibrationdate date, null
- calibrationprovider varchar(150), null
Calibration status stays derived at read time from nextcalibrationdate
(overdue / duesoon / current / unknown, 30-day window), exactly as
measuringtools derived it and for the same reason: a stored status is stale
the day after it is written. The helper moves across unchanged.
This is a net gain rather than a port. A machine could not record calibration at all before, and a part marker with a certified fixture, or a machine with a calibrated probe, had nowhere to put it.
machinetypes.ismetrology answers ADR-005's objection
ADR-005 made one concrete technical argument, and it deserves a concrete answer rather than silence:
"show me all measuring tools" requires an enumeration of measuring-instrument equipmenttype values, which scales badly.
That is correct about enumeration and it is why machinetypes gains a boolean
ismetrology. The metrology view stays a first-class single-column filter -
WHERE mt.ismetrology = 1 - not a hardcoded list of type names that drifts the
first time someone adds an instrument type. The calibration report, the gage
lab view and any compliance export all hang off that flag.
What does not change
assets.gaugelabreferencestays on the core asset. The gage tag was never ameasuringtoolscolumn, so it survives untouched and stays searchable for every asset type.- The collector's device identity file and the
measuringtoolidpayload alias stay accepted. Bays staged withmeasuringtool-id.txtkeep reporting; only the asset type they resolve to changes. - Instrument types keep their names. A Form Tracer is still a Form Tracer, now
as a
machinetypewithismetrology = 1.
Consequences
The migration is free today and expensive later. measuringtools has zero
rows, so retirement is a DROP TABLE, not a data migration. Once the 134
staged instruments are entered they carry relationships, audit history, map
positions and collector links, and every one of those would have to be
rewritten. This ADR is being taken now specifically because the window is open.
A site that did populate it needs a real migration. The reference site did
not and the sister site shows no sign of having done so - its branch contains
no deliberate work on the plugin in its entire history - but that is inference,
not a query against their database. Confirm before the removal ships to another
site. If rows exist, the retirement migration must copy them into machines
with ismetrology types rather than drop them.
Four collector pctypemap entries change asset type. gea-shopfloor-cmm,
-keyence, -genspect and -waxtrace resolve to machine instead of
measuring_tool. The collector:measuringtool relationship label is kept as a
recognised origin marker so links a collector already created are still
archived correctly rather than orphaned.
One fewer of everything. A duplicate type page, a settings group, a plugin migration chain, a gated searcher, a set of dashboard cards, a map colour entry and a label-printing branch all go. That is the point.
ADR-005 is superseded, not reversed in principle. Its reasoning was sound
for the population it described. The population never arrived. If a site ever
does track hand gages in quantity, the answer is a handgages plugin against
that real inventory - not the reinstatement of this one.