fix: stop logging failures from silently breaking PC-machine relationships
Two related fixes in api.asp: 1. CreatePCMachineRelationship now archives stale Controls relationships in BOTH directions (Equipment->PC and the legacy PC->Equipment shape some prod rows use), so a self-registering PC cannot leave a stale controller active alongside its new link. Previously only the Equipment->PC direction was archived, leaving reversed legacy rows dangling. 2. LogToFile now clears Err before returning. It runs under On Error Resume Next; a failed write (logs dir not writable, disk full) left Err set, and CreatePCMachineRelationship tests Err.Number right after a LogToFile call, so a logging failure was misread as fatal and silently aborted relationship creation. Verified live: with the fix, updateCompleteAsset creates the PC, archives the reversed legacy relationship, and links the new PC. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
21
api.asp
21
api.asp
@@ -1821,13 +1821,20 @@ Function CreatePCMachineRelationship(pcMachineid, machineNumber)
|
||||
' previous PC's relationship is stale (PC was replaced). Soft-archive via
|
||||
' isactive=0 keeps history but excludes from active inventory views (the
|
||||
' display pages already filter on isactive=1).
|
||||
'
|
||||
' Match the equipment on EITHER side of the row. Legacy prod data stores
|
||||
' some Controls links reversed (machineid = PC, related_machineid =
|
||||
' equipment) instead of the canonical Equipment -> PC shape this function
|
||||
' writes. A direction-blind archive catches both, so a self-registering
|
||||
' DSC asset cannot leave a stale legacy controller active alongside it.
|
||||
' The new PC's own link (either direction) is preserved by the <> guards.
|
||||
Dim archiveSQL
|
||||
archiveSQL = "UPDATE machinerelationships " & _
|
||||
"SET isactive = 0, lastupdated = NOW() " & _
|
||||
"WHERE machineid = " & CLng(equipmentMachineid) & _
|
||||
" AND related_machineid <> " & CLng(pcMachineid) & _
|
||||
" AND relationshiptypeid = " & CLng(relationshiptypeid) & _
|
||||
" AND isactive = 1"
|
||||
"WHERE relationshiptypeid = " & CLng(relationshiptypeid) & _
|
||||
" AND isactive = 1" & _
|
||||
" AND ( (machineid = " & CLng(equipmentMachineid) & " AND related_machineid <> " & CLng(pcMachineid) & ")" & _
|
||||
" OR (related_machineid = " & CLng(equipmentMachineid) & " AND machineid <> " & CLng(pcMachineid) & ") )"
|
||||
LogToFile "CreatePCMachineRelationship: Archiving stale relationships: " & archiveSQL
|
||||
objConn.Execute archiveSQL
|
||||
If Err.Number <> 0 Then
|
||||
@@ -2732,6 +2739,12 @@ Sub LogToFile(message)
|
||||
|
||||
Set logFile = Nothing
|
||||
Set fso = Nothing
|
||||
|
||||
' Logging is best-effort. A failed write (e.g. logs dir not writable) must
|
||||
' never leak Err into callers - several callers run under On Error Resume
|
||||
' Next and test Err.Number right after a LogToFile call, so a logging
|
||||
' failure would otherwise be misread as a fatal error.
|
||||
Err.Clear
|
||||
End Sub
|
||||
|
||||
' ============================================================================
|
||||
|
||||