Consolidate PC types: use pctypeid instead of multiple machinetypeids
All PCs now use machinetypeid 33 (PC) with pctypeid for sub-type: - Standard, Engineer, Shopfloor, CMM, Wax/Trace, Keyence, Genspect, Heat Treat Added new pctypes: Keyence, Genspect, Heat Treat 🤖 Generated with [Claude Code](https://claude.com/claude-code) Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
44
sql/consolidate_pc_machinetypes.sql
Normal file
44
sql/consolidate_pc_machinetypes.sql
Normal file
@@ -0,0 +1,44 @@
|
|||||||
|
-- Consolidate PC Machine Types
|
||||||
|
-- Date: 2025-12-08
|
||||||
|
--
|
||||||
|
-- Previously PCs used multiple machinetypeids:
|
||||||
|
-- 33: Standard PC
|
||||||
|
-- 34: Engineering PC
|
||||||
|
-- 35: Shopfloor PC
|
||||||
|
-- 42: PC - Wax Trace
|
||||||
|
-- 43: PC - Measuring Tool
|
||||||
|
--
|
||||||
|
-- Now all PCs use machinetypeid 33 (PC) with pctypeid for sub-type
|
||||||
|
|
||||||
|
-- Add new PC types
|
||||||
|
INSERT IGNORE INTO pctype (typename, description, functionalaccountid, isactive, displayorder) VALUES
|
||||||
|
('Keyence', 'Keyence measurement system', 1, 1, 6),
|
||||||
|
('Genspect', 'Genspect inspection system', 1, 1, 7),
|
||||||
|
('Heat Treat', 'Heat treat monitoring', 1, 1, 8);
|
||||||
|
|
||||||
|
-- Rename machinetypeid 33 to just 'PC'
|
||||||
|
UPDATE machinetypes SET machinetype = 'PC' WHERE machinetypeid = 33;
|
||||||
|
|
||||||
|
-- Update pctypeid based on current machinetypeid
|
||||||
|
-- 34 (Engineering PC) -> pctypeid 2 (Engineer)
|
||||||
|
UPDATE machines SET pctypeid = 2 WHERE machinetypeid = 34 AND (pctypeid IS NULL OR pctypeid = 1);
|
||||||
|
|
||||||
|
-- 35 (Shopfloor PC) -> pctypeid 3 (Shopfloor)
|
||||||
|
UPDATE machines SET pctypeid = 3 WHERE machinetypeid = 35 AND (pctypeid IS NULL OR pctypeid = 1);
|
||||||
|
|
||||||
|
-- 42 (PC - Wax Trace) -> pctypeid 6 (Wax / Trace)
|
||||||
|
UPDATE machines SET pctypeid = 6 WHERE machinetypeid = 42 AND (pctypeid IS NULL OR pctypeid = 1);
|
||||||
|
|
||||||
|
-- 43 (PC - Measuring Tool) -> pctypeid 7 (Keyence)
|
||||||
|
UPDATE machines SET pctypeid = 7 WHERE machinetypeid = 43 AND (pctypeid IS NULL OR pctypeid = 1);
|
||||||
|
|
||||||
|
-- Consolidate all PCs to machinetypeid 33
|
||||||
|
UPDATE machines SET machinetypeid = 33 WHERE machinetypeid IN (34, 35, 42, 43);
|
||||||
|
|
||||||
|
-- Verification query
|
||||||
|
-- SELECT pt.pctypeid, pt.typename, COUNT(*) as count
|
||||||
|
-- FROM machines m
|
||||||
|
-- JOIN pctype pt ON m.pctypeid = pt.pctypeid
|
||||||
|
-- WHERE m.pctypeid IS NOT NULL
|
||||||
|
-- GROUP BY pt.pctypeid, pt.typename
|
||||||
|
-- ORDER BY pt.pctypeid;
|
||||||