Remove emojis from all markdown docs, add consolidation plan
- Strip emojis from 47 markdown files across docs/, sql/, and root - Add docs/DOCS_CONSOLIDATION_PLAN.md with plan to reduce 45 docs to 8 - Establish no-emoji rule for documentation going forward 🤖 Generated with [Claude Code](https://claude.com/claude-code) Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
This commit is contained in:
@@ -29,7 +29,7 @@ This session was a continuation of Phase 2 PC migration testing. The main accomp
|
||||
|
||||
**Pages Tested:** 15 out of 123
|
||||
|
||||
**✅ PASSED - Critical PC Pages:**
|
||||
** PASSED - Critical PC Pages:**
|
||||
- displaypcs.asp
|
||||
- displaypc.asp
|
||||
- displaymachines.asp
|
||||
@@ -45,7 +45,7 @@ This session was a continuation of Phase 2 PC migration testing. The main accomp
|
||||
- network_map.asp (after enhancements)
|
||||
- network_devices.asp
|
||||
|
||||
**❌ Issues Found:**
|
||||
** Issues Found:**
|
||||
- displaysubnet.asp - Runtime error (subscript out of range) - NOT FIXED
|
||||
- 3 warranty pages in v2 directory using old schema - NOT FIXED
|
||||
|
||||
@@ -64,7 +64,7 @@ This session was a continuation of Phase 2 PC migration testing. The main accomp
|
||||
<input type="hidden" name="pcid" value="<%=machineid%>">
|
||||
```
|
||||
|
||||
**Status:** ✅ Fixed
|
||||
**Status:** Fixed
|
||||
|
||||
#### Bug 2: updatedevice.asp - Phase 2 Schema Migration
|
||||
**File:** updatedevice.asp
|
||||
@@ -97,7 +97,7 @@ This session was a continuation of Phase 2 PC migration testing. The main accomp
|
||||
' NEW: updateSQL = updateSQL & "lastupdated = NOW() WHERE machineid = ? AND pctypeid IS NOT NULL"
|
||||
```
|
||||
|
||||
**Status:** ✅ Fixed
|
||||
**Status:** Fixed
|
||||
|
||||
#### Bug 3: updatedevice_direct.asp - Phase 2 Schema Migration
|
||||
**File:** updatedevice_direct.asp
|
||||
@@ -130,7 +130,7 @@ This session was a continuation of Phase 2 PC migration testing. The main accomp
|
||||
' NEW: cmdUpdate.Parameters.Append cmdUpdate.CreateParameter("@machineid", 3, 1, , CLng(pcid))
|
||||
```
|
||||
|
||||
**Status:** ✅ Fixed
|
||||
**Status:** Fixed
|
||||
|
||||
---
|
||||
|
||||
@@ -227,7 +227,7 @@ if (sourceTable === 'printers') {
|
||||
|
||||
**Result:** Network map now correctly queries and displays network devices from machines table
|
||||
|
||||
**Status:** ✅ Fixed
|
||||
**Status:** Fixed
|
||||
|
||||
---
|
||||
|
||||
@@ -326,7 +326,7 @@ WHERE mt.machinetypeid IN (16, 17, 18, 19, 20);
|
||||
- network_devices.asp now shows devices from both separate tables AND machines table
|
||||
- Supports future addition of network devices in either location
|
||||
|
||||
**Status:** ✅ Fixed
|
||||
**Status:** Fixed
|
||||
|
||||
---
|
||||
|
||||
@@ -403,7 +403,7 @@ User requested: "i need example switches, idf, cameras"
|
||||
- Only 38 printers remain in vw_network_devices
|
||||
- System proven ready for real network device data
|
||||
|
||||
**Status:** ✅ Created, Tested, and Removed
|
||||
**Status:** Created, Tested, and Removed
|
||||
|
||||
---
|
||||
|
||||
@@ -467,7 +467,7 @@ User requested: "i need example switches, idf, cameras"
|
||||
- Root cause: IIS Express had cached the old compiled ASP
|
||||
- Resolution: Environment restart cleared ASP cache
|
||||
|
||||
**Status:** ✅ Fixed
|
||||
**Status:** Fixed
|
||||
|
||||
---
|
||||
|
||||
@@ -484,7 +484,7 @@ User requested: "i need example switches, idf, cameras"
|
||||
- Displays total count
|
||||
- Confirms map bounds validation
|
||||
|
||||
**Status:** ✅ Created (for troubleshooting)
|
||||
**Status:** Created (for troubleshooting)
|
||||
|
||||
### SQL Scripts Created
|
||||
|
||||
@@ -633,14 +633,14 @@ None - all critical Phase 2 PC functionality working
|
||||
|
||||
## Production Readiness
|
||||
|
||||
### ✅ Ready for Production
|
||||
### Ready for Production
|
||||
- All PC functionality (display, add, edit, update, save)
|
||||
- Phase 2 schema migration complete for critical paths
|
||||
- network_map.asp showing all device types
|
||||
- network_devices.asp unified view working
|
||||
- Security: All pages use parameterized queries
|
||||
|
||||
### ⚠️ Before Production Deployment
|
||||
### Before Production Deployment
|
||||
1. Test remaining 108 ASP pages
|
||||
2. Fix displaysubnet.asp runtime error
|
||||
3. Decide on v2 directory (update or remove)
|
||||
@@ -648,7 +648,7 @@ None - all critical Phase 2 PC functionality working
|
||||
5. Monitor IIS logs for 48 hours after deployment
|
||||
6. Create rollback plan
|
||||
|
||||
### 📊 Current Test Coverage
|
||||
### Current Test Coverage
|
||||
- **Pages Tested:** 15 / 123 (12%)
|
||||
- **Critical Pages:** 15 / 15 (100%)
|
||||
- **Phase 2 Migration:** Complete for PC pages
|
||||
@@ -682,5 +682,5 @@ This was a highly productive session with 6 critical bugs fixed, major enhanceme
|
||||
|
||||
All Phase 2 critical PC functionality is working and tested. The unified architecture allows flexible device storage in either separate tables or the machines table, with the view layer handling the abstraction.
|
||||
|
||||
**Status:** ✅ Session Objectives Met
|
||||
**Status:** Session Objectives Met
|
||||
**Production Readiness:** 85% (core functionality complete, full testing pending)
|
||||
|
||||
Reference in New Issue
Block a user