Files
shopdb/CLAUDE.md
cproudlock d1a93979f2 Fix database schema documentation to match actual tables
- Fix table names: pc_comm_config → commconfig, pc_dnc_config → dncconfig
- Fix column name: communications.gateway → defaultgateway
- Clarify printers uses 'ipaddress' while communications uses 'address'
- Update CREATE TABLE statements to match actual schema
- Add warranties table to QUICK_REFERENCE.md

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-11 17:09:44 -05:00

4.7 KiB

ShopDB - Claude Code Instructions

Project Overview

ShopDB is a Classic ASP/VBScript web application for managing manufacturing shop floor infrastructure at GE Aerospace. It tracks machines, PCs, printers, and network devices.

Technology Stack

  • Backend: Classic ASP (VBScript)
  • Database: MySQL 5.6
  • Frontend: Bootstrap 4.6, jQuery, DataTables
  • Server: IIS on Windows VM (192.168.122.151:8080)
  • Version Control: Gitea (localhost:3000)

Key Architecture

Database Schema (Phase 2 - Current)

machines table (unified)
├── Equipment (machinetypeid 1-24, pctypeid IS NULL)
├── PCs (machinetypeid 33-35, pctypeid IS NOT NULL)
└── Network Devices (machinetypeid 16-20)

printers table (separate)
communications table (all network interfaces)
machinerelationships table (PC↔equipment links)

Key Queries

-- All PCs
SELECT * FROM machines WHERE pctypeid IS NOT NULL;

-- All Equipment
SELECT * FROM machines WHERE pctypeid IS NULL AND machinetypeid < 16;

-- Network devices
SELECT * FROM machines WHERE machinetypeid IN (16,17,18,19,20);

File Structure

/home/camp/projects/windows/shopdb/
├── *.asp              # Main ASP pages
├── api.asp            # REST API for PowerShell
├── includes/          # Shared includes (header, footer, sql)
├── js/                # JavaScript files
├── css/               # Stylesheets
├── images/            # Images and icons
├── docs/              # Documentation
├── sql/               # SQL scripts
│   ├── migration_phase1/
│   ├── migration_phase2/
│   └── migration_phase3/
└── logs/              # Application logs

Log Locations

IIS Logs (Windows VM): /home/camp/projects/windows/logs/shopdb/

  • Format: ex[YYMMDD].log (e.g., ex251201.log for Dec 1, 2025)
  • These are synced from the Windows VM via Samba share
  • Contains HTTP request logs with status codes and error messages

API Logs: Check logs/ folder in shopdb directory on IIS

Coding Standards

ASP/VBScript

  1. Always use parameterized queries - Never concatenate user input into SQL
  2. Use HTMLEncode for output - Prevent XSS attacks
  3. Convert text fields to strings - Use & "" to avoid type mismatch errors
  4. Use Option Explicit - Declare all variables

Example Safe Query

Dim cmd, rs
Set cmd = Server.CreateObject("ADODB.Command")
cmd.ActiveConnection = objConn
cmd.CommandText = "SELECT * FROM machines WHERE machineid = ?"
cmd.Parameters.Append cmd.CreateParameter("@id", 3, 1, , machineId)
Set rs = cmd.Execute()

Example Safe Output

' Always convert to string and encode
Dim hostname
hostname = ""
If NOT IsNull(rs("hostname")) Then hostname = rs("hostname") & ""
Response.Write(Server.HTMLEncode(hostname))

Common Tasks

Reading Files

  • Main pages are in project root (*.asp)
  • Includes are in /includes/
  • Check docs/ for documentation

Making Changes

  1. Read the file first
  2. Use parameterized queries for any SQL
  3. Test on dev server (192.168.122.151:8080)
  4. Check IIS logs for errors

Database Access

docker exec -it dev-mysql mysql -u root -prootpassword shopdb

Important Notes

VBScript Limitations

  • No IIf() function - use If-Then-Else instead
  • No Try-Catch - use On Error Resume Next carefully
  • Strings are 1-indexed, not 0-indexed

Column Name Gotchas

  • address not ipaddress in communications table (but printers uses ipaddress)
  • defaultgateway not gateway in communications table
  • machinenotes not notes in machines table
  • machineid not pcid for PCs in machines table
  • commconfig and dncconfig tables (not pc_comm_config, pc_dnc_config)

PC Identification

PCs are in the machines table, identified by:

  • pctypeid IS NOT NULL
  • machinetypeid IN (33, 34, 35)

API Endpoints

Base URL: http://192.168.122.151:8080/api.asp

Action Method Description
updateCompleteAsset POST PC data collection
getDashboardData GET Health check
updatePrinterMapping POST Printer assignments

External Integrations

Page Purpose
printerlookup.asp?ip=x.x.x.x Zabbix printer lookup by IP/FQDN

Quick Reference

Start Dev Environment

~/start-dev-env.sh
~/status-dev-env.sh

Git Commands

cd /home/camp/projects/windows/shopdb
git status
git add .
git commit -m "message"
git push

Test a Page