sync_intune.bat: longer poll interval, in-place status, no sync flood
Two related fixes for the desktop helper: 1. Stop hammering the Intune sync trigger every 15 seconds. The old loop called :do_sync (Start-ScheduledTask on Schedule #3) on every failed check, which started a fresh CSP pull before the previous one had time to complete - the Intune engine treats a re-trigger as "start over" and kills in-flight policy application work, so nothing ever finished. New cadence: trigger sync once at the start of each step, then poll every 30 s, only re-trigger every 6 polls (~3 min). POLL_SECS and RETRIGGER_POLLS are top-of-script knobs. 2. Stop pushing the QR code off the top of the window. The old loop echoed "Checking again in 15s..." on a new line every iteration, so after a few minutes the QR code (which contains the device ID the operator scans) had scrolled out of view. Replaced the per- iteration echo with a single self-redrawing status line using a captured CR character (copy /Z trick) and <nul set /p, padded to clear leftover characters. Important transitions ("Re-triggering sync...", "[DONE] ...") still print echo. lines so they survive in the scrollback as permanent history. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -9,6 +9,11 @@ if !errorlevel! neq 0 (
|
||||
exit /b
|
||||
)
|
||||
|
||||
:: Capture a carriage return character so the polling status line can overwrite
|
||||
:: itself in place (instead of scrolling the QR code off the top of the window).
|
||||
:: The copy /Z trick is the standard batch idiom for getting a literal CR.
|
||||
for /f %%a in ('copy /Z "%~f0" nul') do set "CR=%%a"
|
||||
|
||||
echo.
|
||||
echo ========================================
|
||||
echo Intune Policy Sync - %COMPUTERNAME%
|
||||
@@ -48,15 +53,37 @@ echo Step 3: SFLD - Consume Credentials task
|
||||
echo ========================================
|
||||
echo.
|
||||
|
||||
:: ---- Polling cadence ----
|
||||
:: An Intune policy pull (Schedule #3 task) typically takes 30-90 seconds end-to-end.
|
||||
:: We poll every POLL_SECS but only RE-TRIGGER sync every RETRIGGER_POLLS iterations
|
||||
:: (so the previous sync has time to actually complete before we kick a new one).
|
||||
:: Old version called do_sync every 15s, which started a fresh sync before the prior
|
||||
:: one had finished and the Intune CSP engine treated each re-trigger as "start over",
|
||||
:: killing in-flight policy application work.
|
||||
set "POLL_SECS=30"
|
||||
set "RETRIGGER_POLLS=6"
|
||||
|
||||
:: ---- STEP 1: Wait for SFLD registry key ----
|
||||
echo [Step 1/3] Waiting for SFLD device configuration...
|
||||
echo Triggering initial Intune sync...
|
||||
call :do_sync
|
||||
set "poll_count=0"
|
||||
|
||||
:poll_sfld
|
||||
reg query "HKLM\Software\GE\SFLD" >nul 2>&1
|
||||
if !errorlevel! equ 0 goto sfld_done
|
||||
call :do_sync
|
||||
echo Checking again in 15s...
|
||||
timeout /t 15 /nobreak >nul
|
||||
if !errorlevel! equ 0 (
|
||||
echo.
|
||||
goto sfld_done
|
||||
)
|
||||
set /a poll_count+=1
|
||||
set /a remainder=!poll_count! %% !RETRIGGER_POLLS!
|
||||
if !remainder! equ 0 (
|
||||
echo.
|
||||
echo Still waiting after !poll_count! checks - re-triggering sync...
|
||||
call :do_sync
|
||||
)
|
||||
<nul set /p "=!CR! Check #!poll_count! - next check in !POLL_SECS!s... "
|
||||
timeout /t !POLL_SECS! /nobreak >nul
|
||||
goto poll_sfld
|
||||
|
||||
:sfld_done
|
||||
@@ -65,6 +92,9 @@ echo [DONE] SFLD device configuration received.
|
||||
:: ---- STEP 2: Wait for DSC install completion ----
|
||||
echo.
|
||||
echo [Step 2/3] Waiting for DSC installation to complete...
|
||||
echo Triggering initial Intune sync...
|
||||
call :do_sync
|
||||
set "poll_count=0"
|
||||
|
||||
:poll_dsc
|
||||
set "dsc_ok=0"
|
||||
@@ -72,10 +102,19 @@ if exist "C:\LOGS\SFLD\DSCInstall.log" (
|
||||
findstr /C:"Installation completed successfully" "C:\LOGS\SFLD\DSCInstall.log" >nul 2>&1
|
||||
if !errorlevel! equ 0 set "dsc_ok=1"
|
||||
)
|
||||
if !dsc_ok! equ 1 goto dsc_done
|
||||
call :do_sync
|
||||
echo Checking again in 15s...
|
||||
timeout /t 15 /nobreak >nul
|
||||
if !dsc_ok! equ 1 (
|
||||
echo.
|
||||
goto dsc_done
|
||||
)
|
||||
set /a poll_count+=1
|
||||
set /a remainder=!poll_count! %% !RETRIGGER_POLLS!
|
||||
if !remainder! equ 0 (
|
||||
echo.
|
||||
echo Still waiting after !poll_count! checks - re-triggering sync...
|
||||
call :do_sync
|
||||
)
|
||||
<nul set /p "=!CR! Check #!poll_count! - next check in !POLL_SECS!s... "
|
||||
timeout /t !POLL_SECS! /nobreak >nul
|
||||
goto poll_dsc
|
||||
|
||||
:dsc_done
|
||||
@@ -84,13 +123,25 @@ echo [DONE] DSC installation completed successfully.
|
||||
:: ---- STEP 3: Wait for Consume Credentials scheduled task ----
|
||||
echo.
|
||||
echo [Step 3/3] Waiting for SFLD - Consume Credentials task...
|
||||
echo Triggering initial Intune sync...
|
||||
call :do_sync
|
||||
set "poll_count=0"
|
||||
|
||||
:poll_task
|
||||
schtasks /query /tn "SFLD - Consume Credentials" >nul 2>&1
|
||||
if !errorlevel! equ 0 goto task_done
|
||||
call :do_sync
|
||||
echo Checking again in 15s...
|
||||
timeout /t 15 /nobreak >nul
|
||||
if !errorlevel! equ 0 (
|
||||
echo.
|
||||
goto task_done
|
||||
)
|
||||
set /a poll_count+=1
|
||||
set /a remainder=!poll_count! %% !RETRIGGER_POLLS!
|
||||
if !remainder! equ 0 (
|
||||
echo.
|
||||
echo Still waiting after !poll_count! checks - re-triggering sync...
|
||||
call :do_sync
|
||||
)
|
||||
<nul set /p "=!CR! Check #!poll_count! - next check in !POLL_SECS!s... "
|
||||
timeout /t !POLL_SECS! /nobreak >nul
|
||||
goto poll_task
|
||||
|
||||
:task_done
|
||||
|
||||
Reference in New Issue