- CMM imaging pipeline: WinPE-staged bootstrap + on-logon enforcer
against tsgwp00525 share, manifest-driven installer runner shared via
Install-FromManifest.ps1. Installs PC-DMIS 2016/2019 R2, CLM 1.8,
goCMM; enables .NET 3.5 prereq; registers GE CMM Enforce logon task
for ongoing version enforcement.
- Shopfloor serial drivers: StarTech PCIe serial + Prolific PL2303
USB-to-serial via Install-Drivers.cmd wrapper calling pnputil
/add-driver /subdirs /install. Scoped to Standard PCs.
- OpenText extended to CMM/Keyence/Genspect/WaxAndTrace via
preinstall.json PCTypes; Defect Tracker added to CMM profile
desktopApps + taskbarPins.
- Configure-PC startup-item toggle now persists across the logon
sweep via C:\\ProgramData\\GE\\Shopfloor\\startup-overrides.json;
06-OrganizeDesktop Phase 3 respects suppressed items.
- Get-ProfileValue helper added to Shopfloor/lib/Get-PCProfile.ps1;
distinguishes explicit empty array from missing key (fixes Lab
getting Plant Apps in startup because empty array was falsy).
- 06-OrganizeDesktop gains transcript logging at C:\\Logs\\SFLD\\
06-OrganizeDesktop.log and now deletes the stale Shopfloor Intune
Sync task when C:\\Enrollment\\sync-complete.txt is present (task
was registered with Limited principal and couldn't self-unregister).
- startnet.cmd CMM xcopy block (gated on pc-type=CMM) stages the
bundle to W:\\CMM-Install during WinPE.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Adds a machine number prompt to startnet.cmd after the Standard sub-type
selection. Tech enters the number during the PXE boot process. Defaults
to 9999 if Enter is pressed (existing placeholder behavior).
Written to C:\Enrollment\machine-number.txt alongside pc-type.txt.
Consumers:
00-PreInstall-MachineApps.ps1 - replaces 9999 in UDC InstallArgs with
the entered number, so UDC installs with the correct machine number
from the start (no post-setup Set-MachineNumber needed).
01-eDNC.ps1 - writes the machine number to the DNC\General\MachineNo
registry value during eDNC install.
Configure-PC.ps1 - existing $needsMachineNumber check already skips
the prompt when UDC/eDNC aren't at 9999, so no change needed.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
BUILTIN\Users (Limited RunLevel) can't delete scheduled tasks, so
Unregister-ScheduledTask failed silently and the sync task kept firing
at every logon even after completion.
Fix: write C:\Enrollment\sync-complete.txt on completion. At script
startup in -AsTask mode, check for the marker and exit immediately if
found. The task stays in Task Scheduler but does nothing -- fires at
logon, sees marker, exits in under a second. No visible window.
Manual sync_intune.bat runs (no -AsTask) ignore the marker and always
show the full status display for inventory QR code purposes.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Chrome (installed by PPKG) now gets the same profile-driven homepage
and startup tabs as Edge. Uses HKLM:\SOFTWARE\Policies\Google\Chrome
with the same policy keys (RestoreOnStartup, RestoreOnStartupURLs,
HomepageLocation, HomepageIsNewTabPage, ShowHomeButton).
Reuses the $startupTabs and $homepageUrl already resolved for Edge
from the PC profile, so both browsers show identical tabs. Skips
cleanly if Chrome isn't installed.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three changes to eliminate the redundant startup-item picker during
the imaging chain:
06-OrganizeDesktop.ps1 - new Phase 3: auto-apply startup items
Reads pcProfile.startupItems (or site-wide default) and creates
.lnk files in AllUsers Startup folder. Supports exe, existing, and
url types (same as Configure-PC). Idempotent - skips items that
already exist so manual changes aren't overwritten. Runs during
shopfloor setup finalization, so the tech doesn't need to select
startup items again.
Configure-PC.ps1 - new -MachineNumberOnly switch
When set, skips the entire startup-items section and only shows the
machine number prompt (if UDC/eDNC at 9999). Used by sync_intune
-AsTask after completion. Full startup picker still available when
the tech opens Configure-PC.bat manually from the desktop.
Monitor-IntuneProgress.ps1 - simplified -AsTask completion
After post-reboot DSC complete: unregisters task, launches
Configure-PC -MachineNumberOnly, exits. Tech uses sync_intune.bat
on the desktop to see QR code for inventory purposes.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The QR code text was built once at script startup. If the device wasn't
AAD-joined yet, it showed "Device not yet Azure AD joined" forever -
even after Phase 1 checks passed. Now regenerates Build-QRCodeText
when Phase1.AzureAdJoined transitions to true.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Install-ProvisioningPackage triggers an immediate reboot that kills
run-enrollment.ps1 before it can register the sync_intune task or do
any post-install work. BPRT app installs happen on the NEXT boot, not
before the reboot.
Fix: move sync task registration into Run-ShopfloorSetup.ps1, executed
BEFORE calling run-enrollment.ps1. The task is safely registered while
we still have control. Then enrollment installs the PPKG and lets it
reboot. After reboot, BPRT finishes in background, sync task fires at
logon, monitors Intune enrollment (which is independent of BPRT).
Run-ShopfloorSetup.ps1:
- Registers "Shopfloor Intune Sync" @logon task after desktop tool
copies but BEFORE enrollment
- Flushes transcript before calling enrollment (since PPKG reboot
will kill us, ensures log is complete)
- Enrollment is the absolute last call
run-enrollment.ps1:
- Stripped to essentials: find PPKG, rename computer, set OOBE,
Install-ProvisioningPackage
- No BPRT polling (irrelevant - happens after reboot)
- No task registration (already done by caller)
- No shutdown call (PPKG handles it)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The imaging chain needs exactly 2 autologons after the first boot
(sync_intune pre-reboot + post-reboot). Setting to 4 adds 2 extra
reboots of margin for unexpected restarts from Windows Update, PPKG
file operations, or script crashes.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Em dashes (U+2014) and arrows (U+2192) break PowerShell 5.1 on
Windows when the file has no UTF-8 BOM -- byte 0x94 gets read as
a right double quote in Windows-1252, silently closing strings
mid-parse. This caused run-enrollment.ps1 to fail on PXE-imaged
machines with "string is missing the terminator" at line 113.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Install-ProvisioningPackage is async — it queues the provisioning engine
and returns immediately. The actual BPRT app installs (Chrome, Office,
Tanium, CyberArk, etc.) run in the background. Without waiting, the
PPKG reboot fires while installs are still in progress, leaving apps
partially installed.
Fix: poll for C:\Logs\BPRT\Remove Staging Locations\Log.txt — the last
BPRT step. When that file exists, all provisioning steps have completed.
Polls every 10 seconds for up to 15 minutes (Office install can be slow).
Progress logged every 30 seconds showing which steps have finished.
If the timeout fires (15 min), logs a warning and proceeds — the SYSTEM
logon task from 06-OrganizeDesktop.ps1 provides self-healing on the next
boot for anything that was incomplete.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three final optimization batches:
1. Start-Transcript added to 4 scripts that lacked standalone logging:
04-NetworkAndWinRM.ps1, 05-OfficeShortcuts.ps1, 01-eDNC.ps1,
02-MachineNumberACLs.ps1. Each writes to C:\Logs\SFLD\<name>.log
with append mode. Stop-Transcript added before exit points.
2. preinstall.json: Oracle Client PCTypes changed from ["*"] to
["Standard", "CMM", "Genspect", "Keyence", "WaxAndTrace", "Display"].
Lab Workstations don't need Oracle Client (shopfloor data app
dependency). VC++ redists stay at ["*"] (harmless shared deps).
3. Edge profiles added to all remaining PC types in site-config.json:
CMM, Genspect, Keyence, WaxAndTrace, Standard-Timeclock all get the
standard 3-tab setup (Plant Apps + Homepage + Dashboard) with
homepage = tsgwp00524. Display-Lobby and Display-Dashboard get
Shopfloor Dashboard as both homepage and single tab.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three optimization batches from the pipeline audit:
1. Shared Update-MachineNumber.ps1 helper (lib/)
Extracts duplicated machine-number update logic from Configure-PC.ps1,
Check-MachineNumber.ps1, and Set-MachineNumber.ps1 into a shared
dot-sourceable helper at Shopfloor/lib/Update-MachineNumber.ps1.
Exports:
Get-CurrentMachineNumber → @{ Udc = $string; Ednc = $string }
Update-MachineNumber -NewNumber <n> [-Site <s>] → @{ UdcUpdated; EdncUpdated; Errors }
All three consumers now dot-source the helper instead of duplicating
~50 lines each. Set-MachineNumber.ps1 also migrated from inline
Get-SiteConfig to dot-sourcing Get-PCProfile.ps1 for consistency.
2. Site-config integration for remaining scripts
Setup-OpenText.ps1: exclude lists (profiles + shortcuts) now read from
site-config.json opentext section, falling back to West Jefferson
defaults. Inline Get-SiteConfig since the script runs from
C:\PreInstall\installers\opentext\ (can't dot-source Get-PCProfile).
00-PreInstall-MachineApps.ps1: after parsing preinstall.json, scans
InstallArgs for "West Jefferson" and replaces with site-config
siteName if different. Inline Get-SiteConfig for same reason.
3. Placeholder type-specific directories
Created skeleton 01-Setup-*.ps1 scripts for all PC types so the
directory structure is in place and Run-ShopfloorSetup's type-specific
loop has something to iterate over:
Genspect/01-Setup-Genspect.ps1
Keyence/01-Setup-Keyence.ps1
WaxAndTrace/01-Setup-WaxAndTrace.ps1
Lab/01-Setup-Lab.ps1
Each logs a "no type-specific apps configured yet" banner and exits.
Fill in app installs when details are finalized; for share-based
installs, copy the CMM/01-Setup-CMM.ps1 pattern.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Refactored CMM/01-Setup-CMM.ps1 from local-file installer to network-
share-based pattern. CMM apps live on a file share instead of being
pre-staged locally or pulled from Azure Blob.
Framework:
1. Reads share path from site-config.json CMM profile (cmmSharePath),
falls back to West Jefferson default
2. Scans HKLM:\SOFTWARE\GE\SFLD\Credentials\* for a credential entry
whose TargetHost matches the share's server name
3. Mounts the share as S: using net use with the stored creds
4. (Placeholder) Install apps from the share
5. Disconnects the share
The Get-SFLDCredential helper function is generic and will be reused by
Genspect/Keyence scripts when their share-based installs are built. It
matches credentials by TargetHost field, supporting exact match and
domain-suffix matching.
App install blocks are commented out as placeholders — uncomment when
PC-DMIS, CLM License, and other Hexagon app details are finalized.
Added cmmSharePath to site-config.json CMM profile.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Adds a pcProfiles section to site-config.json that lets each PC type (and
optional sub-type) override startupItems, taskbarPins, and desktopApps.
Scripts resolve: pcProfile > site-wide default > hardcoded fallback.
New shared helper: Shopfloor/lib/Get-PCProfile.ps1
Dot-sourced by consuming scripts. Reads pc-type.txt + pc-subtype.txt,
builds a profile key (e.g. "Standard-Machine"), and looks it up in
site-config.json pcProfiles. Exports $siteConfig, $pcType, $pcSubtype,
$profileKey, $pcProfile for the caller to use.
Replaces the inline Get-SiteConfig function that was copy-pasted into
each script. Scripts now do:
. "$PSScriptRoot\lib\Get-PCProfile.ps1"
instead of duplicating the loader.
startnet.cmd changes:
- Added Lab as PC type option (7)
- Standard now has a sub-type menu: Timeclock / Machine
- Display sub-type menu also writes PCSUBTYPE for consistency
- pc-subtype.txt written alongside pc-type.txt when sub-type selected
- site-config.json copied from enrollment share to W:\Enrollment\
site-config.json v2.0:
- New pcProfiles section with profiles for:
Standard-Timeclock, Standard-Machine, CMM, Genspect, Keyence,
WaxAndTrace, Lab, Display-Lobby, Display-Dashboard
- CMM/Genspect/Keyence/WaxAndTrace profiles have TODO comments for
type-specific apps (placeholder with WJ Shopfloor baseline only)
- Lab/Display profiles have empty startupItems and desktopApps
- Top-level startupItems/taskbarPins/desktopApps remain as site-wide
defaults (used when no profile matches)
Updated scripts:
06-OrganizeDesktop.ps1 - desktopApps from profile > site > hardcoded
07-TaskbarLayout.ps1 - taskbarPins from profile > site > hardcoded
08-EdgeDefaultBrowser.ps1 - uses shared profile loader
Configure-PC.ps1 - startupItems from profile > site > hardcoded
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
New site-config.json file at C:\Enrollment\ (staged by startnet.cmd from
the enrollment share) contains all West Jefferson-specific values that were
previously hardcoded across 7 scripts. To deploy at a different GE site,
clone site-config.json and change the values - scripts need zero changes.
Config schema (v1.0):
siteName / siteNameCompact - UDC/eDNC site args
urls{} - Edge startup tab fallback URLs
edgeStartupTabs[] - ordered tab list with .url file basenames
opentext{} - excluded .hep profiles and .lnk shortcuts
startupItems[] - Configure-PC toggle list (exe/existing/url)
taskbarPins[] - 07-TaskbarLayout pin order with lnk paths
desktopApps[] - 06-OrganizeDesktop Phase 2 app list
Every script uses the same inline Get-SiteConfig helper that reads the
JSON and returns $null if missing/corrupt. All consumers fall back to the
current hardcoded West Jefferson defaults when $siteConfig is null, so
PXE servers without a site-config.json continue working identically.
Scripts updated:
06-OrganizeDesktop.ps1 - desktopApps array from config
07-TaskbarLayout.ps1 - pinSpec array from config
08-EdgeDefaultBrowser.ps1 - startup tab loop from config
Configure-PC.ps1 - startup items + site name from config
Check-MachineNumber.ps1 - site name from config
Set-MachineNumber.ps1 - site name from config
01-eDNC.ps1 - siteName + siteNameCompact from config
startnet.cmd - copies site-config.json from enrollment share
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Two related fixes from the pipeline audit:
1. Stage-Dispatcher race condition (critical):
Run-ShopfloorSetup.ps1 called shutdown /r /t 10 and the dispatcher
had to write the next stage + register RunOnce within that 10-second
window. If disk I/O was slow, the reboot fired before RunOnce was
registered, and the chain broke.
Fix: dispatcher now cancels Run-ShopfloorSetup's pending reboot
(shutdown /a) immediately after it returns, then advances the stage
and registers RunOnce with no time pressure, then initiates its own
shutdown /r /t 5.
2. Dispatcher owns all reboots:
Run-ShopfloorSetup.ps1 now checks the -FromDispatcher flag at the
end. When called by the dispatcher, it schedules shutdown /r /t 30
as a safety net (the dispatcher cancels it immediately). When called
standalone (manual run or legacy FirstLogonCommands), it reboots
directly with /t 10 as before.
This means the dispatcher has full control over the reboot lifecycle:
cancel -> advance stage -> register RunOnce -> reboot. No racing.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The stage-file gate in Run-ShopfloorSetup.ps1 would fire even when
called by Stage-Dispatcher.ps1 (because the stage file still contains
"shopfloor-setup"), causing an infinite exit loop.
Fix: Run-ShopfloorSetup now accepts -FromDispatcher switch. The gate
only fires when the switch is absent (i.e. when called by the unattend's
FirstLogonCommands). Stage-Dispatcher passes -FromDispatcher when
invoking Run-ShopfloorSetup, bypassing the gate.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Run-ShopfloorSetup.ps1 now checks for C:\Enrollment\setup-stage.txt at
the very top. If the stage file exists (written by run-enrollment.ps1),
the script exits immediately with "deferring to Stage-Dispatcher.ps1
on next logon". This prevents the unattend's FirstLogonCommands chain
from running Run-ShopfloorSetup in the same session as run-enrollment,
which was bypassing the entire staged reboot chain.
Without this gate:
FirstLogonCommand #1: run-enrollment.ps1 (sets stage file + RunOnce)
FirstLogonCommand #2: Run-ShopfloorSetup.ps1 (runs immediately, ignoring stage)
PPKG reboot fires after both complete
Next boot: dispatcher has nothing to do (Run-ShopfloorSetup already ran)
With the gate:
FirstLogonCommand #1: run-enrollment.ps1 (sets stage file + RunOnce)
FirstLogonCommand #2: Run-ShopfloorSetup.ps1 (sees stage file, exits)
PPKG reboot fires
Next boot: RunOnce fires dispatcher, reads "shopfloor-setup", runs
Run-ShopfloorSetup properly (stage file deleted by gate on re-entry)
Also: Monitor-IntuneProgress.ps1 RetriggerMinutes bumped from 3 to 5.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replaces the single-session "cancel PPKG reboot and cram everything into
one autologon" flow with a staged chain where each reboot advances to the
next step automatically. The technician touches the keyboard 3 times total
(UNPLUG prompt, Y to reboot, Configure-PC selections).
New Stage-Dispatcher.ps1:
Reads C:\Enrollment\setup-stage.txt and chains through:
shopfloor-setup -> sync-intune -> configure-pc
Each stage re-registers HKLM RunOnce so the dispatcher fires again on
the next logon. Stage file is deleted when the chain completes.
Transcript logged to C:\Logs\SFLD\stage-dispatcher.log.
Stage "shopfloor-setup": runs Run-ShopfloorSetup.ps1 (which reboots via
shutdown /r /t 10). Dispatcher advances stage to sync-intune in the
~10 second window before the machine goes down, re-registers RunOnce.
Stage "sync-intune": launches Monitor-IntuneProgress.ps1 -Unattended.
Exit 2 (pre-reboot done, user confirmed): dispatcher re-registers
RunOnce and initiates shutdown /r /t 5. Stage stays at sync-intune so
the monitor picks up post-reboot state on next boot.
Exit 0 (post-reboot install complete): dispatcher chains directly to
Configure-PC.ps1 in the same session, then deletes the stage file.
Stage "configure-pc": runs Configure-PC.ps1 and deletes the stage file.
Fallback entry point if the post-reboot chain was interrupted.
Modified run-enrollment.ps1:
Removed the shutdown /a that canceled the PPKG reboot. Instead writes
setup-stage.txt = "shopfloor-setup" and registers RunOnce for the
dispatcher. PPKG reboot fires naturally (handles PendingFileRename
operations like Zscaler rename and PPKG self-cleanup). Now tracked in
the git repo at playbook/shopfloor-setup/run-enrollment.ps1.
Modified Monitor-IntuneProgress.ps1:
New -Unattended switch. When set:
Invoke-SetupComplete exits 0 without waiting for keypress.
Invoke-RebootPrompt exits 2 without prompting or rebooting (dispatcher
handles both). Manual sync_intune.bat usage (no flag) unchanged.
RetriggerMinutes bumped from 3 to 5 (user request).
Modified startnet.cmd:
Now also copies Stage-Dispatcher.ps1 from the PXE server to
W:\Enrollment\Stage-Dispatcher.ps1 alongside run-enrollment.ps1.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Don't prompt the user to reboot until the enrollment pipeline has
finished its pre-reboot work. Previously Test-RebootState fired as
soon as DSCDeployment.log showed "completed", even if Phase 1 (Identity)
or Phase 2 (SFLD config) checks were still in progress.
Now the reboot prompt requires ALL of these to be green in the snapshot:
Phase 1: AzureAdJoined, IntuneEnrolled, EmTaskExists, PoliciesArriving
Phase 2: SfldRoot, FunctionOk, SasTokenOk
Phase 3: DeployLogExists, DeployComplete
This prevents the edge case where DSCDeployment.log completes but the
user reboots before Intune policies have fully landed, which could leave
the post-reboot DSC install phase without the SAS token or function
assignment it needs.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
1. UDC JSON ACL: set on directory C:\ProgramData\UDC\ with
ContainerInherit+ObjectInherit instead of the file. UDC_Setup.exe
gets killed by KillAfterDetection before UDC.exe creates
udc_settings.json, so the file doesn't exist at ACL-grant time.
Directory-level ACL with inheritance covers any file created later.
2. Set-MachineNumber.ps1 auto-running: the type-specific loop's
Get-ChildItem -Filter "*.ps1" picked up the desktop tool alongside
the numbered installer scripts. Added Where-Object { $_.Name -match
'^\d' } so only numbered-prefix scripts (01-eDNC, 02-ACLs) run.
3. WJ Shopfloor copy-to-self: Phase 1 sweep moved WJ Shopfloor.lnk
into Shopfloor Tools\, then Phase 2's Find-ExistingLnk found it
there and tried to Copy-Item to the same path. Now checks if
resolved source path == destination and prints "exists: (already
in Shopfloor Tools)" instead of erroring.
4. NTLARS missing from taskbar pins: the $pinSpec entry was never
added to 07-TaskbarLayout.ps1 despite the comment update. Added
between eDNC and Defect_Tracker in pin order.
5. shutdown /a stderr noise: 15+ red "Unable to abort system shutdown"
lines in the transcript from shutdown.exe writing to stderr when no
shutdown is pending. Changed all occurrences in Run-ShopfloorSetup,
00-PreInstall-MachineApps to: cmd /c "shutdown /a 2>nul" *>$null
which suppresses both native stderr and PS error stream.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
New tools:
Configure-PC.bat/.ps1 - Interactive desktop tool for SupportUser to
configure a shopfloor PC after imaging. Two sections:
1. Machine number: if UDC/eDNC are still at placeholder 9999, prompt
to set the real number right now (updates UDC JSON + eDNC registry,
restarts UDC.exe with new args).
2. Auto-startup toggle: pick which apps start at user logon from a
numbered list (UDC, eDNC, Defect Tracker, WJ Shopfloor, Plant Apps).
Creates/removes .lnk files in AllUsers Startup folder. Toggle UI
shows [ON]/[ ] state, safe to re-run anytime. Plant Apps URL
resolved from .url file at runtime with hardcoded fallback to
https://mes-wjefferson.apps.lr.geaerospace.net/run/...
3. Item 6 in the toggle list: register/unregister a "Check Machine
Number" logon task for standard (non-admin) users. When enabled,
the task fires at every logon, checks for 9999, pops an InputBox
if found, updates both apps, then unregisters itself on success.
Check-MachineNumber.ps1 - The logon task script. Runs as the logged-in
user (needs GUI for InputBox), not SYSTEM. Writing to ProgramData + HKLM
is possible because 02-MachineNumberACLs.ps1 pre-grants BUILTIN\Users
write access on the two specific targets during imaging.
02-MachineNumberACLs.ps1 - Standard type-specific script (runs after
01-eDNC.ps1). Opens C:\ProgramData\UDC\udc_settings.json for Users:Modify
and HKLM:\...\GE Aircraft Engines\DNC\General for Users:SetValue. Narrow
scope, not blanket admin.
Execution order fixes in Run-ShopfloorSetup.ps1:
The dispatcher now has two lists: $skipInBaseline (scripts NOT run in the
alphabetical baseline loop) and $runAfterTypeSpecific (scripts run
explicitly after type-specific scripts complete). This fixes the bug where
06/07 ran before 01-eDNC.ps1 installed DnC, so eDNC/NTLARS shortcuts were
silently skipped.
New execution order:
Baseline: 00-PreInstall, 04-NetworkAndWinRM (skipping 05-08 + tools)
Type-specific: 01-eDNC, 02-MachineNumberACLs
Finalization: 06-OrganizeDesktop, 07-TaskbarLayout
06 internally calls 05 (Office shortcuts, Phase 0) and 08 (Edge config,
Phase 4) as sub-phases, so they also benefit from running late. Office
isn't installed until after the first reboot (ppkg streams C2R), so 05
no-ops at imaging time but succeeds when 06's SYSTEM logon task re-runs
it on the second boot. 08 resolves startup-tab URLs from .url files
delivered by DSC (even later); same self-heal via the logon task.
Other fixes in this commit:
- OpenText Setup-OpenText.ps1 Step 4: exclude WJ_Office.lnk, IBM_qks.lnk,
mmcs.lnk desktop shortcuts (matching the Step 3 .hep profile exclusion
from the previous commit). Removes stale copies from prior installs.
- 05-OfficeShortcuts.ps1: widened Office detection to 6 path variants
covering C2R + MSI + Office15/16, with diagnostic output on miss.
- 06-OrganizeDesktop.ps1: removed Phase 3 (desktop-root pin copies for
eDNC/NTLARS) so shortcuts live in Shopfloor Tools only, not duplicated
at root. Emptied $keepAtRoot. Added Phase 0 (call 05) and Phase 4
(call 08). Lazy folder creation + empty-folder cleanup. Scheduled task
now runs as SYSTEM (was BUILTIN\Users with Limited which failed the
admin check). Added NTLARS to 07's taskbar pin list.
- 08-EdgeDefaultBrowser.ps1: Plant Apps URL fallback hardcoded from
device-config.yaml.
- All new scripts have Start-Transcript logging to C:\Logs\SFLD\ with
timestamps and running-as identity.
- Run-ShopfloorSetup.ps1: Start-Transcript + Stop-Transcript wrapping
entire dispatcher run, writes to C:\Logs\SFLD\shopfloor-setup.log.
Configure-PC.bat added to SupportUser desktop copy list.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three new baseline scripts that run during shopfloor imaging to clean up
the end-user Public Desktop. Before this, Azure AD users logged into a
shopfloor PC and saw 20+ loose shortcuts at the desktop root (Office
apps, OpenText sessions, WJ web portals, DNC utilities, Defect Tracker,
plus .url files for every intranet page) with no organization. End users
couldn't find anything.
06-OrganizeDesktop.ps1 - Single source of truth for Public Desktop layout
Phase 1: sweeps loose shortcuts at the desktop root into three category
folders - Office\, Shopfloor Tools\, Web Links\ - by filename regex,
extension, and .lnk target resolution. Allowlists eDNC.lnk and
NTLARS.lnk to stay at root since end users click them too often.
Unknown items are left at the root on purpose (never delete).
Phase 2: materializes specific app shortcuts into Shopfloor Tools\.
UDC / eDNC / NTLARS are built fresh from their .exe paths; WJ
Shopfloor and Defect_Tracker are MSI-advertised (empty TargetPath,
Darwin descriptor) so we copy the existing .lnk from wherever it
lives via a multi-location lookup. Each entry is conditional on its
source being present - script runs cleanly on PC types without DnC.
Phase 3: drops eDNC.lnk and NTLARS.lnk at desktop root from the
Shopfloor Tools\ copies, so end users have both a folder version
and a quick-access root version.
Phase 4: registers an "Organize Public Desktop" scheduled task that
re-runs phase 1 at every logon. Shortcuts added later by DSC /
Intune / msiexec get filed automatically without another imaging
pass. Admin check at the top, -ErrorAction Stop on Register-
ScheduledTask and directory creation so failures are caught
instead of printing false success.
07-TaskbarLayout.ps1 - Minimal taskbar pinner
Checks which .lnk files 06 created in Shopfloor Tools\, then writes
LayoutModification.xml to the Default User profile with taskbar pins
in order: Edge, WJ Shopfloor, UDC, eDNC, Defect_Tracker. No shortcut
creation in this script - all shortcut management lives in 06.
Missing .lnks are skipped (PC types without DnC just get fewer pins).
Applies on first logon of new user profiles (Azure AD users after
enrollment). Existing profiles don't re-read Default User - Windows
design limitation since 1703, no programmatic fix.
08-EdgeDefaultBrowser.ps1 - Edge as default browser + startup tabs
Motivated by the ppkg installing Chrome alongside Edge: new Azure AD
users hit a "Choose your default app" picker on first URL click
because nothing is marked default. Two layers:
1. dism /Online /Import-DefaultAppAssociations:<xml> writes an XML
with Edge ProgIds for http/https/.htm/.html/.pdf/.svg/.webp into
the Default User profile template. New profiles inherit.
2. HKLM:\SOFTWARE\Policies\Microsoft\Windows\System\
DefaultAssociationsConfiguration registry value (the "Set a
default associations configuration file" GPO) points at the same
XML so Windows re-applies on every logon, catching Windows-update
defaults-reset cases.
Leaves Chrome installed, just not the default URL handler.
Also sets Edge startup tabs via machine-wide policies under
HKLM:\SOFTWARE\Policies\Microsoft\Edge:
RestoreOnStartup = 4 (open specific URLs)
RestoreOnStartupURLs = Plant Apps, WJ Shop Floor Homepage, Shopfloor
Dashboard (tab order per spec)
HomepageLocation = first tab (Plant Apps)
HomepageIsNewTabPage = 0
ShowHomeButton = 1
URLs are resolved dynamically from the .url files on the Public
Desktop (or Web Links\ after the sweep), so if WJDT changes a URL
later the script picks it up without a code change. Fallbacks are
hardcoded for the two portals we have URLs memorized for; Plant Apps
has no fallback and will be skipped if the .url file is missing.
Test workflow: admin-check in all three scripts fails fast on non-
elevated runs instead of spamming half-successful Access Denied output
like the first draft did.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Long debugging round on the shopfloor test PC with several overlapping
bugs. This commit folds all the fixes together.
sync_intune.bat
- Slim down to an elevation thunk that launches a NEW elevated PS
window via Start-Process -Verb RunAs (with -NoExit so the window
doesn't vanish on error). All UI now lives in the PS monitor, not
mixed into the cmd launcher.
- Goto-based control flow. Earlier version had nested if (...) blocks
with literal parens inside echo lines (e.g. "wrappers (Install-eDNC,
...etc)."); cmd parses if-blocks by counting parens character-by-
character, so the ")" in "etc)." closed the outer block early and
the leftover "." threw ". was unexpected at this time.", crashing
the elevated cmd /c window before pause ran.
- Multi-location Monitor-IntuneProgress.ps1 lookup so the user's
quick-test workflow (drop both files on the desktop) works without
manually editing the hardcoded path. Lookup order:
1. %~dp0lib\Monitor-IntuneProgress.ps1
2. %~dp0Monitor-IntuneProgress.ps1
3. C:\Users\SupportUser\Desktop\Monitor-IntuneProgress.ps1
4. C:\Enrollment\shopfloor-setup\Shopfloor\lib\Monitor-IntuneProgress.ps1
- Prints "Launching: <path>" as its first line so you can see which
copy it actually loaded. This caught a bug where a stale desktop
copy was shadowing the canonical file via fallback #2.
Set-MachineNumber.bat
- Same multi-location lookup pattern. Old version used
%~dp0Set-MachineNumber.ps1 and bombed when the bat was copied to
the desktop without its .ps1 sibling.
- Goto-based dispatch, no nested parens, for the same parser reason.
Monitor-IntuneProgress.ps1
- Start-Transcript at the top, writing to C:\Logs\SFLD\ (falls back
to %TEMP% if C:\Logs\SFLD isn't writable yet) with a startup banner
including a timestamp. Every run leaves a captured trace.
- Main polling loop wrapped in try/catch/finally. Unhandled exceptions
print a red report with type, message, position, and stack trace,
then block on Wait-ForAnyKey so the window can't auto-close on a
silent crash.
- Console window resize at startup via $Host.UI.RawUI.WindowSize /
BufferSize, wrapped in try/catch (Windows Terminal ignores it, but
classic conhost honors it).
- Clear-KeyBuffer / Read-SingleKey / Wait-ForAnyKey helpers. Drain any
buffered keystrokes from the polling loop before each prompt so an
accidental keypress can't satisfy a pause prematurely.
- Invoke-SetupComplete / Invoke-RebootPrompt final-state handlers.
The REBOOT REQUIRED branch now shows a yellow 3-line header, a
four-line explanation, and a cyan "Press Y to reboot now, or N to
cancel:" prompt via Read-SingleKey @('Y','N'). Y triggers
Restart-Computer -Force (with shutdown.exe fallback), N falls
through to Wait-ForAnyKey.
- Display order: status table FIRST, QR LAST. The cursor ends below
the QR so the viewport always follows it - keeps the QR on screen
regardless of window height. Works on both classic conhost and
Windows Terminal (neither reliably honors programmatic resize).
- Half-block QR renderer: walks QRCoder's ModuleMatrix directly and
emits U+2580 / U+2584 / U+2588 / space, one output line per two
matrix rows. Halves the rendered height vs AsciiQRCode full-block.
Quiet zone added manually via $pad=4 since QRCoder's ModuleMatrix
doesn't include one. Trade-off: may not be perfectly square on all
fonts, but the user accepted that for the smaller footprint after
multiple iterations comparing full-block vs half-block vs PNG popup.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Two related fixes from a debugging round on the test PC:
1. PreInstall runner: detection-during-install kill is now opt-in via
"KillAfterDetection: true" on JSON entries that need it. Old behavior
killed any installer as soon as its detection passed - which broke
Oracle: Oracle creates its registry key partway through install,
the runner detected it at the 25s poll, killed msiexec mid-install,
and msiserver was still doing rollback when the next install (VC++
2008) started - so VC++ 2008 hit ERROR_INSTALL_ALREADY_RUNNING
(1618). Only UDC needs the detection-kill (its installer spawns a
hidden WPF window and never exits). Other installers exit cleanly
on their own and shouldn't be killed.
2. Track Setup-OpenText scripts in git. The bundled OpenText install
scripts (Setup-OpenText.ps1, Setup-OpenText.cmd, version.txt) live
at runtime in /home/camp/pxe-images/main/dependencies/opentext/
alongside the binary install files (~106 MB of MSI/CAB/MSP/MST plus
profile content). The binaries stay outside git but the script
logic and version stamp are mirrored into playbook/preinstall/
opentext/ here so git history captures changes to the install
logic and version bumps. README.md explains the workflow.
Latest Setup-OpenText.ps1 includes:
- $SourceDir default moved into script body (PowerShell evaluates
param([string]$X = $PSScriptRoot) defaults at parameter-binding
time, when $PSScriptRoot may not yet be populated, so the
default came out as empty string and Join-Path crashed)
- Logging set up FIRST so any startup error gets captured
- REBOOT=ReallySuppress dropped from both msiexec calls (base MSI
and SP1 patch) - OpenText installs shell extensions that hook
explorer.exe, and Restart Manager closes explorer to replace
the shell DLLs. With REBOOT=ReallySuppress, RM closed explorer
but interpreted the relaunch as a "reboot action" and refused
to do it, leaving the user with no desktop. /norestart on its
own prevents the actual Windows reboot but lets RM cleanly
close-and-relaunch explorer mid-install.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
When the runner runs a Type:MSI install it injects /L*v <log> and tails
that log on failure to show what actually went wrong. Type:EXE installs
had no equivalent - if Setup-OpenText.cmd or any other EXE wrapper
failed, the installlog just showed "Exit code 1 - FAILED" with no clue
what happened inside.
Adds an optional LogFile field to JSON entries. When present on a
Type:EXE entry, the runner:
- Logs "Installer log: <path>" before launching the installer
- On failure, tails the last 30 lines of that file into the runner
log (same pattern as the MSI verbose log scan)
Wired up on the OpenText entry to point at C:\Logs\PreInstall\Setup-
OpenText.log (which Setup-OpenText.ps1 already writes itself). Other
EXE entries can opt in by adding their own LogFile field.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Run-ShopfloorSetup.ps1 line 46-47 does:
Get-ChildItem -Path $baselineDir -Filter "*.ps1" -File | Sort-Object Name
foreach ($script in $scripts) { & $script.FullName }
This picks up EVERY *.ps1 in Shopfloor\ and runs it as a baseline
script. Last commit (66d13d8) put Monitor-IntuneProgress.ps1 in that
same directory, which means the dispatcher was running it as the LAST
baseline script (M sorts after 00/04/05). The monitor is an infinite
poll loop that never returns until the SFLD lifecycle is complete -
so the dispatcher hung there forever, and Standard\01-eDNC.ps1 and
Standard\Set-MachineNumber.ps1 never ran.
Symptoms in the test run:
- 00-PreInstall-MachineApps.ps1 ran (10 installed, 1 OpenText fail)
- 04-NetworkAndWinRM.ps1 ran silently
- 05-OfficeShortcuts.ps1 ran silently
- Monitor-IntuneProgress.ps1 started (Clear-Host + status table) and
hung in its main loop
- eDNC + Set-MachineNumber never ran
Fix: move Monitor-IntuneProgress.ps1 into Shopfloor\lib\ so the
dispatcher's non-recursive Get-ChildItem doesn't see it. Update
sync_intune.bat's MONITOR path to the new location, and add a
comment explaining WHY the monitor lives under lib\ to prevent this
mistake from being repeated.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replaces the 3-step pass/fail polling that lived in the .bat with a
PowerShell monitor that renders a full status table for the SFLD
enrollment lifecycle and handles the pre-reboot -> reboot -> post-reboot
transition explicitly.
Three structural problems with the old script:
1. Step 3 ("SFLD - Consume Credentials task exists") fired too early.
The task is created by SetupCredentials.log around 08:52 in the
pre-reboot phase, NOT post-reboot, so passing all 3 gates didn't
actually mean "fully done" - it just meant "credential setup ran".
2. No detection of the pre-reboot -> reboot -> post-reboot transition.
The script never read DSCDeployment.log, so it couldn't tell the
user "you need to reboot now to start the install phase". A device
stuck waiting for reboot was indistinguishable from one still
syncing.
3. No visibility into Phase 4 (per-script wrappers like Install-eDNC,
Install-UDC, Install-VCRedists, Install-OpenText). When something
hung you had to manually grep C:\Logs\SFLD\.
New layout:
sync_intune.bat - thin launcher (~50 lines): self-elevate, invoke
Monitor-IntuneProgress.ps1, branch on exit code
(0 = done / 2 = reboot needed / else = error).
Monitor-IntuneProgress.ps1 - the actual monitor (~340 lines):
- 5-phase status table (Identity / SFLD config / DSC deployment +
install / Custom scripts / Final) updated every 30s via Clear-
Host + redraw, with the QR code anchored at the top.
- Phase 4 auto-discovers custom scripts by parsing DSCInstall.log
for "Downloading script: <name>" lines AND scanning C:\Logs\SFLD\
Install-*.log files - so Display PCs running entirely different
scripts surface their own list automatically without hardcoding.
Statuses: pending / running / done / failed (mtime + tail-based).
- Boot-loop-safe reboot detection via Test-RebootState: only signals
'needed' if DSCDeployment.log was modified AFTER LastBootUpTime.
Once we've rebooted past it, just waits for DSCInstall.log.
- Caches monotonic Phase 1 indicators (AzureAdJoined, IntuneEnrolled,
EnterpriseMgmt task) so dsregcmd /status (slow ~1-2s) only runs
until the flag flips true, not on every poll.
- Triggers Intune sync at startup, re-triggers every 3 minutes (was
every 15 seconds in the old loop, which actively interrupted
in-flight CSP work).
Exit codes consumed by sync_intune.bat:
0 - DSCInstall.log shows "Installation completed successfully"
2 - DSCDeployment.log shows "Deployment completed successfully" AND
the deploy log is newer than LastBootUpTime (= reboot needed)
1 - error
Detection markers (decoded from a captured run at /home/camp/pxe-images/
Logs/ - see comment block at top of Monitor-IntuneProgress.ps1).
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Office Click-to-Run installs the binaries when an Office-bearing ppkg
is selected (e.g. GCCH_Prod_SFLD_StdOffice-x86_*) but doesn't create
desktop shortcuts - operators only see Office in the Start Menu's
Microsoft 365 folder. This baseline script fills that gap.
Self-detects Office by EXE existence at C:\\Program Files\\Microsoft
Office\\root\\Office16\\ or the (x86) equivalent. No Office found =
silent no-op, so it's safe to run on every PC type (Display kiosks,
Wax/Trace, Keyence, etc.) without needing a per-type filter.
Creates Excel.lnk / Word.lnk / PowerPoint.lnk in two places:
- C:\\Users\\Public\\Desktop\\ - visible to all users immediately
- C:\\Users\\Default\\AppData\\Roaming\\Microsoft\\Windows\\Start
Menu\\Programs\\ - inherited by every NEW user profile created
on the device (Azure AD operator logons after enrollment)
Numbered 05- so it runs after 00-PreInstall and 04-NetworkAndWinRM
in the Shopfloor baseline sequence. Idempotent - WScript.Shell's
CreateShortcut overwrites existing .lnks each run.
Outlook / OneNote / Access / Publisher intentionally not shortcutted
(scope decision; can be added by extending the $officeApps array).
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Two related fixes for the desktop helper:
1. Stop hammering the Intune sync trigger every 15 seconds. The old
loop called :do_sync (Start-ScheduledTask on Schedule #3) on every
failed check, which started a fresh CSP pull before the previous
one had time to complete - the Intune engine treats a re-trigger
as "start over" and kills in-flight policy application work, so
nothing ever finished. New cadence: trigger sync once at the start
of each step, then poll every 30 s, only re-trigger every 6 polls
(~3 min). POLL_SECS and RETRIGGER_POLLS are top-of-script knobs.
2. Stop pushing the QR code off the top of the window. The old loop
echoed "Checking again in 15s..." on a new line every iteration,
so after a few minutes the QR code (which contains the device ID
the operator scans) had scrolled out of view. Replaced the per-
iteration echo with a single self-redrawing status line using a
captured CR character (copy /Z trick) and <nul set /p, padded to
clear leftover characters. Important transitions ("Re-triggering
sync...", "[DONE] ...") still print echo. lines so they survive in
the scrollback as permanent history.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three observability fixes that made the VC++ MSI failures actually
debuggable instead of showing "Exit code - FAILED" with an empty
value for every install:
1. Switch from Start-Process -PassThru (without -Wait) to
[System.Diagnostics.Process]::Start() with a ProcessStartInfo.
PowerShell 5.1 has a known bug where Start-Process disposes the
Process object's OS handle when control returns to the script,
so $proc.ExitCode reads as $null even after WaitForExit() - which
was causing every MSI install to be reported as failed regardless
of the actual result.
2. Pass /L*v <log> to msiexec on every MSI install so we get a full
verbose log per app at C:\Logs\PreInstall\msi-<safename>.log.
3. On install failure, scan the verbose log for *meaningful* lines
(Note: 1: <code>, "return value 3", custom action errors, "Failed
to", "Installation failed", common 2xxx error codes) instead of
tailing the last 25 lines, which is rollback/cleanup noise. This
surfaces the actual root-cause line directly in the runner log so
you don't have to dig through C:\Logs to diagnose.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replace em-dash characters with plain hyphens across the 5 shopfloor
setup scripts (avoids cp1252 mojibake in .bat files and keeps the
PowerShell sources consistent). Also adds [Parameter(Position=1)] to
Write-PreInstallLog so the Level argument can be passed positionally.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Adds a local-install pipeline so Standard shopfloor PCs get Oracle, the
VC++ redists (2008-2022), and UDC installed during PXE imaging via Samba
instead of pulling ~215 MB per device from Azure blob over the corporate
WAN. Intune DSC then verifies (already-installed apps are skipped) and
the only Azure traffic on the happy path is ~11 KB of CustomScripts
wrapper polling.
New files:
- playbook/preinstall/preinstall.json — curated app list with PCTypes
filter and per-app detection rules. Install order puts VC++ 2008
LAST so its (formerly) reboot-triggering bootstrapper doesn't kill
the runner mid-loop. (2008 itself now uses extracted vc_red.msi with
REBOOT=ReallySuppress; the reorder is defense in depth.)
- playbook/shopfloor-setup/Shopfloor/00-PreInstall-MachineApps.ps1 —
the runner. Numbered 00- so it runs first in the baseline sequence.
Reads preinstall.json, filters by PCTYPE, polls for completion via
detection check (handles UDC's hung WPF process by killing it once
detection passes), uses synchronous WriteThrough logging that
survives hard reboots, preserves log history across runs.
- playbook/shopfloor-setup/Standard/Set-MachineNumber.{ps1,bat} — desktop
helper for SupportUser. Reads current UDC + eDNC machine numbers,
prompts via VB InputBox, validates digits-only, kills running UDC,
edits both C:\ProgramData\UDC\udc_settings.json and HKLM\…\GE Aircraft
Engines\DNC\General\MachineNo, relaunches UDC. Lets a tech assign a
real machine number to a mass-produced PC without admin/LAPS.
- playbook/sync-preinstall.sh — workstation helper to push installer
binaries from /home/camp/pxe-images/main/ to the live PXE Samba.
Changes:
- playbook/startnet.cmd + startnet-template.cmd — add xcopy to stage
preinstall bundle from Y:\preinstall\ to W:\PreInstall\ during the
WinPE imaging phase, gated on PCTYPE being set.
- playbook/pxe_server_setup.yml — create /srv/samba/enrollment/preinstall
+ installers/ directories and deploy preinstall.json there.
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1 — bump AutoLogonCount
to 99 at start (defense against any installer triggering an immediate
reboot mid-dispatcher; final line still resets to 2 on successful
completion). Copy Set-MachineNumber.{ps1,bat} to SupportUser desktop
on Standard PCs.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- Delete 02-OpenTextCSF.ps1 (CSF profile delivery moved to Intune YAML's
CopyFiles section in main/device-config.yaml — no longer needed at the
PXE/baseline layer)
- Strip MarkZebra install + post-config from 01-eDNC.ps1 (no longer
needed; only eDNC core install + Dnc x86→x64 mirror + Site reg + eMxInfo
deployment remain). Section numbering tightened.
- Add SITESELECTED="West Jefferson" to eDNC msiexec args so the MSI's
site-specific Components (NtLarsWjfRegComp — FTP/FMS/PPDCS hosts +
credentials) actually install. Without it, only the bare Site value was
being set and all the connection details were unconfigured.
- gitignore: blanket-block any **/eMxInfo*.txt from being committed —
the file contains obfuscated eDNC site credentials and must never go
in git. Canonical source lives at /home/camp/pxe-images/main/eMxInfo.txt
outside the repo.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Bundles QRCoder.dll (184KB, .NET 4.0) to render the Azure AD device
GUID as a scannable QR code in the console when sync_intune.bat runs.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- AutoLogonCount reduced from 2 to 1 in Run-ShopfloorSetup.ps1
- Remove default pinned Start Menu tiles and set blank layout for future users
- Add sync_intune.bat: triggers MDM sync and polls for SFLD group policies
- Update README.md and SETUP.md with current project state (boot chain, new
scripts, samba shares, webapp pages, commit history)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- Fix check-bios.cmd: replace parenthesized if blocks with goto labels
(cmd.exe fails silently with if/else on network-mapped drives)
- Move BIOS check files to winpeapps/_shared/BIOS for reliable SMB access
- Add network wait loop before BIOS check in startnet.cmd
- Show firmware status in WinPE menu header (BIOS_STATUS variable)
- Add BypassNRO registry key to skip OOBE network requirement
- Refactor download-drivers.py with --parallel N flag (ThreadPoolExecutor)
- Set SupportUser AutoLogonCount to 3 in shopfloor unattend
- Add shutdown -a at start + shutdown /r /t 10 at end of Run-ShopfloorSetup.ps1
- Switch download-drivers.py from wget to curl for reliable stall detection
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>