- winpe-status-push.ps1: check-bios.cmd stages the firmware update before the imaging menu, but startnet's 'BIOS firmware update' push only comes at the end of WinPE, so builds showed a plain 'Applying image' for the whole apply. The first push now reports the staged update when X:\bios-fired.flag exists, and the floor shows 'Applying image - BIOS update staged' (do not power off during the next reboot). Also: CIM fallback for the serial where wmic is missing, and standard/engineer always report 5 steps. - Network pill: cdc_ncm (e.g. the WisdPI RTL8157 5G adapter) keeps link speed in a 32-bit bits/s field, so 5 Gb/s reads 705 Mb/s; show the real speed with a note. Tested in the win11 VM (with and without the BIOS flag, and the late startnet push).
106 lines
3.9 KiB
PowerShell
106 lines
3.9 KiB
PowerShell
# winpe-status-push.ps1 - Posts "WinPE: PESetup / WIM apply" status to the
|
|
# PXE webapp /imaging/status endpoint so the imaging dashboard reflects
|
|
# this bay BEFORE Run-ShopfloorSetup.ps1 takes over post-PPKG.
|
|
#
|
|
# Runs in WinPE's stripped PowerShell - cannot rely on Get-NetAdapter,
|
|
# Get-CimInstance, or the NetTCPIP module (none are present in stock
|
|
# WinPE). Uses wmic for both serial and MAC.
|
|
#
|
|
# Best-effort: never blocks imaging. All steps log to
|
|
# X:\Windows\Temp\winpe-status-push.log; failures are swallowed.
|
|
|
|
param(
|
|
[string]$PxeServer = '172.16.9.1',
|
|
[int]$Port = 9009,
|
|
[int]$TimeoutSec = 5,
|
|
[string]$PCType = $env:PCTYPE,
|
|
[string]$CurrentStage = 'WinPE: PESetup / WIM apply',
|
|
[int]$StageIndex = 1,
|
|
# check-bios.cmd (run before the imaging menu) writes this when it staged
|
|
# a firmware update; the flash itself happens at the reboot after WinPE.
|
|
[string]$BiosFlag = 'X:\bios-fired.flag'
|
|
)
|
|
|
|
$logFile = 'X:\Windows\Temp\winpe-status-push.log'
|
|
function Log {
|
|
param([string]$msg)
|
|
try { "$(Get-Date -Format s) $msg" | Out-File -FilePath $logFile -Append -Encoding utf8 } catch { }
|
|
}
|
|
|
|
Log "=== winpe-status-push start ==="
|
|
Log "server=${PxeServer}:${Port} pctype=$PCType"
|
|
|
|
# Serial via wmic. Always available in WinPE 10+.
|
|
$serial = ''
|
|
try {
|
|
$line = (& wmic bios get serialnumber /value 2>$null | Where-Object { $_ -match '=' } | Select-Object -First 1)
|
|
if ($line) { $serial = ($line -split '=', 2)[1].Trim() }
|
|
} catch { Log "serial wmic exception: $_" }
|
|
if (-not $serial) {
|
|
# wmic is a removable feature on newer Windows; CIM where it exists.
|
|
try { $serial = ((Get-CimInstance -ClassName Win32_BIOS -ErrorAction Stop).SerialNumber -as [string]).Trim() } catch { }
|
|
}
|
|
Log "serial=$serial"
|
|
|
|
# MAC via wmic NIC enumeration. NetEnabled filter restricts to up adapters.
|
|
$mac = ''
|
|
try {
|
|
$macLines = & wmic nic where 'NetEnabled=TRUE' get MacAddress /value 2>$null |
|
|
Where-Object { $_ -match 'MacAddress=' }
|
|
if ($macLines) {
|
|
$first = ($macLines | Select-Object -First 1)
|
|
$mac = (($first -split '=', 2)[1]).Trim() -replace '-', ':'
|
|
}
|
|
} catch { Log "mac wmic exception: $_" }
|
|
Log "mac=$mac"
|
|
|
|
if (-not $serial) {
|
|
Log "no serial captured - aborting POST"
|
|
exit 0
|
|
}
|
|
|
|
# gea-standard / gea-engineer set no PCTYPE: read the image from the share
|
|
# startnet mapped as Z: (\\server\winpeapps\<image>). Those builds report
|
|
# 5 steps (WinPE, then Send-ImagingStage.ps1 from their unattend); the
|
|
# shopfloor build reports 8.
|
|
$total = 8
|
|
if (-not $PCType) {
|
|
try {
|
|
$z = (& net use Z: 2>$null | Out-String)
|
|
if ($z -match 'winpeapps\\(gea-standard|gea-engineer)\b') { $PCType = $Matches[1]; $total = 5 }
|
|
} catch { Log "net use Z: exception: $_" }
|
|
Log "image from Z: = '$PCType'"
|
|
}
|
|
if ($PCType -in @('gea-standard', 'gea-engineer')) { $total = 5 }
|
|
|
|
# Say so from the first push: the BIOS update was staged before the menu, but
|
|
# startnet's own "BIOS firmware update" push only comes at the end of WinPE.
|
|
if ($CurrentStage -eq 'WinPE: PESetup / WIM apply' -and (Test-Path $BiosFlag)) {
|
|
$CurrentStage = 'WinPE: PESetup / WIM apply (BIOS update staged, flashes on the next reboot)'
|
|
Log "bios flag present: $((Get-Content $BiosFlag -ErrorAction SilentlyContinue) -join ' ')"
|
|
}
|
|
|
|
# Compose JSON. ConvertTo-Json works in WinPE.
|
|
$payload = @{
|
|
serial = $serial
|
|
pctype = $PCType
|
|
current_stage = $CurrentStage
|
|
stage_index = $StageIndex
|
|
stage_total = $total
|
|
status = 'in_progress'
|
|
}
|
|
if ($mac) { $payload.mac = $mac }
|
|
$body = $payload | ConvertTo-Json -Compress
|
|
$uri = "http://${PxeServer}:${Port}/imaging/status"
|
|
Log "POST $uri body=$body"
|
|
|
|
try {
|
|
$resp = Invoke-WebRequest -Uri $uri -Method POST -Body $body `
|
|
-ContentType 'application/json' -UseBasicParsing -TimeoutSec $TimeoutSec -ErrorAction Stop
|
|
Log "OK http=$($resp.StatusCode)"
|
|
} catch {
|
|
Log "ERR $($_.Exception.Message)"
|
|
}
|
|
|
|
exit 0
|