cproudlock 12c6c771dc Stage the two universal print drivers at imaging time
A bay comes off the line unable to build a printer queue. Set-ShopdbPrinters.ps1
creates queues against drivers that are already present and skips any that are
not, so a freshly imaged PC silently gets no printers until some later
enforcement cycle tops it up.

The two universals are 100 MB and resolve the overwhelming majority of the
fleet's printers. The four device-specific drivers are another 126 MB and are
deliberately NOT here - they belong only on bays that own that hardware, and
those bays pick them up from the runtime manifest.

NO WAVE GATE on these entries, unlike the runtime ones. Waves exist because ~300
bays share one runtime share and GE-Enforce spreads them across only five
minutes; imaging runs a handful of bays at a time on the isolated PXE LAN that
already moves multi-GB WIMs, so there is no stampede to prevent.

DETECTION IS THE SPOOLER'S OWN KEY, not pnputil, and the difference is not
cosmetic. Installing a printer driver is two steps: pnputil /add-driver stages
the package into the driver store, Add-PrinterDriver registers it with the
spooler. Get-PrinterDriver - which is what Set-ShopdbPrinters consults - reads
the spooler. Measured on a Win11 bay: after Remove-PrinterDriver the spooler
reports the driver gone while pnputil still lists the package, so a pnputil-
detected entry would report compliant forever while every queue kept skipping. A
broken bay that looks healthy is the worst outcome available here.

The payload is not in git, matching every other installer under preinstall/:
stage printer-drivers/ onto the PXE share alongside the rest.
2026-08-19 17:16:38 -04:00

246 lines
22 KiB
JSON

{
"Version": "1.0",
"Site": "West Jefferson",
"Applications": [
{
"_comment": "PowerShell 7.5.4 - installed BEFORE PPKG via FlatUnattendW10-shopfloor.xml FirstLogonCommand Order 6 (race fix: Intune SetupCredentials Win32App install command starts with pwsh.exe; if PS7 not yet installed when that Win32App fires, it errors with FILE_NOT_FOUND 0x80070002 and IME's GRS retry never re-fires under V3Processor). This entry is a backstop - no-op via ProductCode detection if unattend Order 6 already installed it. PreEnrollment flag is informational; runner does not currently filter on it.",
"Name": "PowerShell 7.5.4",
"Installer": "powershell7\\PowerShell-7.5.4-win-x64.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ADD_PATH=1 USE_MU=0 ENABLE_MU=0 DISABLE_TELEMETRY=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{E8159677-ACF8-4D64-9D36-5C36B8BBEA39}",
"PreEnrollment": true,
"PCTypes": ["*"]
},
{
"_comment": "Oracle Client 11.2 Administrator - installed first because downstream apps (eDNC/NTLARS/UDC and CMM tooling) link against the Oracle home and fail cold if it's missing. Installer is a .cmd wrapper (Type=EXE is the preinstall runner's shim for non-MSI launchers, same pattern as OpenText Setup-OpenText.cmd). The wrapper expects Oracle_OracleDatabase_11r2_V03.zip (686 MB) staged next to it, unpacks to %TEMP%, runs Oracle Universal Installer silently with ge_client_install.rsp, then cleans up the staging dir. OUI exit 3 is treated as success (warnings-but-ok). Detection via the registered home key; downstream upgrades or version pins are handled by the runtime enforcer's Oracle Client 11.2 manifest entry in common/manifest.json. Scoped to the DNC-bearing PC types (collections, nocollections, partmarker, heattreat) plus CMM, whose metrology tooling links the Oracle home; non-DNC types (Genspect, Keyence, WaxAndTrace, Display, Timeclock, Lab) do not get it.",
"Name": "Oracle Client 11.2",
"Installer": "oracle\\Install-Oracle11r2.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\OracleClient\\install.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Oracle\\KEY_OraClient11g_home1",
"DetectionName": "ORACLE_HOME_NAME",
"DetectionValue": "OraClient11g_home1",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-partmarker", "gea-shopfloor-heattreat", "gea-shopfloor-cmm"]
},
{
"_comment": "VC++ 2008 SP1 x86 - the bootstrapper (vcredist2008_x86.exe) ignores /norestart and triggers an immediate Windows reboot when files are in use (per Aaron Stebner's MSDN docs). Fix: install the extracted vc_red.msi directly with REBOOT=ReallySuppress, which IS hard-honored by Windows Installer. msiexec may return 3010 (would-have-rebooted-but-suppressed) but won't actually reboot. cab name 'vc_red.cab' is hardcoded in the MSI's Media table - do not rename.",
"Name": "VC++ Redistributable 2008 x86",
"Installer": "vcredist/2008/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{9BE518E6-ECC6-35A9-88E4-87755C07200F}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2010 x86 - same fix as 2008. Bootstrapper ignores /norestart; extracted MSI with REBOOT=ReallySuppress does not.",
"Name": "VC++ Redistributable 2010 x86",
"Installer": "vcredist/2010/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2012 x86 Minimum Runtime - extracted from vcredist2012_x86.exe Burn bundle. Same REBOOT=ReallySuppress fix.",
"Name": "VC++ Redistributable 2012 x86 (Minimum)",
"Installer": "vcredist/2012-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2012 x86 (Additional)",
"Installer": "vcredist/2012-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{B175520C-86A2-35A7-8619-86DC379688B9}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x86 Minimum Runtime - extracted from vcredist2013_x86.exe Burn bundle.",
"Name": "VC++ Redistributable 2013 x86 (Minimum)",
"Installer": "vcredist/2013-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{13A4EE12-23EA-3371-91EE-EFB36DDFFF3E}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2013 x86 (Additional)",
"Installer": "vcredist/2013-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F8CFEB22-A2E7-3971-9EDA-4B11EDEFC185}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x64 Minimum Runtime - required by Keyence VR-6000 Series Software. Extracted from the Keyence installer's Windows Installer cache. Same REBOOT=ReallySuppress pattern as the x86 variants.",
"Name": "VC++ Redistributable 2013 x64 (Minimum)",
"Installer": "vcredist/2013-x64-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{A749D8E6-B613-3BE3-8F5F-045C84EBA29B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x64 Additional Runtime - required by Keyence VR-6000 Series Software. Pairs with the Minimum Runtime above.",
"Name": "VC++ Redistributable 2013 x64 (Additional)",
"Installer": "vcredist/2013-x64-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{929FBD26-9020-399B-9A7A-751D61F0B942}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2010 x64 - required by PC-DMIS 2016/2019 R2 on CMM PCs. PCDLRN.exe links against msvcr100.dll and the VS 2010 MFC DLLs which are only provided by this redistributable. Extracted from the PC-DMIS 2016 bundle's attached container (a1 payload). Silent install: /q /norestart. Detection: Uninstall key under the native x64 hive with fixed product GUID.",
"Name": "VC++ Redistributable 2010 x64",
"Installer": "vcredist/2010-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{1D8E6291-B0D5-35EC-8441-6616F567A0F7}",
"DetectionName": "DisplayVersion",
"DetectionValue": "10.0.40219",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2012 x64 - required by PC-DMIS 2016/2019 R2. Same rationale as 2010 x64; PC-DMIS links against msvcr110.dll / MFC110. Extracted from the PC-DMIS 2016 bundle's attached container (a2 payload). Detection on the Minimum Runtime GUID (the main redist wrapper installs both Minimum and Additional sub-packages).",
"Name": "VC++ Redistributable 2012 x64",
"Installer": "vcredist/2012-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{5AF4E09F-5C9B-3AAF-B731-544D3DC821DD}",
"DetectionName": "DisplayVersion",
"DetectionValue": "11.0.51106",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2015-2022 x86 - extracted from vcredist2015_2017_2019_2022_x86.exe Burn bundle. The bundle contains 2022 14.44.35211 plus 8 chained KB updates for older 2015/2017/2019 releases. We install only the 2022 Min+Add MSIs - the CRT v140 ABI is shared across 2015/2017/2019/2022, so the latest pair covers all four versions on Windows 10/11.",
"Name": "VC++ Redistributable 2022 x86 (Minimum)",
"Installer": "vcredist/2022-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{922480B5-CAEB-4B1B-AAA4-9716EFDCE26B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2022 x86 (Additional)",
"Installer": "vcredist/2022-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{C18FB403-1E88-43C8-AD8A-CED50F23DE8B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2015-2022 x64 - required by PC-DMIS 2026 (PCDLRN.exe links vcruntime140_1.dll, added in VC++ 2019 / v14.20). The x64 redist line above previously stopped at 2013, so 64-bit PC-DMIS 2026 was missing its runtime and PCDLRN.exe failed to start with 'vcruntime140_1.dll was not found'. The patched PC-DMIS MSI bypasses Hexagon's Burn bundle, which is what would otherwise have pulled this in. Full vc_redist.x64.exe (14.44.35211, 2015-2022 shared CRT). Modern bootstrapper honors /norestart. Detect on the DLL itself so it is version-independent.",
"Name": "VC++ Redistributable 2015-2022 x64",
"Installer": "vcredist/2022-x64/vc_redist.x64.exe",
"Type": "EXE",
"InstallArgs": "/install /quiet /norestart",
"DetectionMethod": "File",
"DetectionPath": "C:\\Windows\\System32\\vcruntime140_1.dll",
"PCTypes": ["*"]
},
{
"_comment": "Adobe Acrobat Reader DC - same version as GEA-Engineering image. Two-step install via Install-AcroReader.cmd wrapper: base MSI with enterprise transform (AcroRead.mst) then DC update patch (AcroRdrDCUpd2500120531.msp). Source files on PXE server at /srv/samba/winpeapps/gea-engineer/Deploy/Applications/extra/adobe/ - copy to /srv/samba/enrollment/preinstall/installers/adobe/.",
"Name": "Adobe Acrobat Reader DC",
"Installer": "adobe\\Install-AcroReader.cmd",
"Type": "EXE",
"InstallArgs": "",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\Adobe\\Acrobat Reader DC\\Reader\\AcroRd32.exe",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "OpenText HostExplorer 15 SP1 ShopFloor - replaced the WJDT-built OpenText.exe Inno wrapper with our own Setup-OpenText.ps1 that does the same install steps (msiexec base + ShopFloor.mst transform + SP1 .msp patch) PLUS fans the per-user profile/keymap/menu/macro content out to Default User and every existing user profile. The Inno wrapper deployed per-user content to {userappdata} which resolves to whichever user is running the installer (SYSTEM under DSC, single user under PreInstall) so Azure-AD users never saw the profiles. Setup-OpenText.cmd is a tiny launcher that hands off to Setup-OpenText.ps1 because the runner only handles MSI/EXE types. All bundled files live in vcredist-style subtree at dependencies/opentext/ and get xcopied through WinPE staging. NO DetectionMethod here on purpose - Setup-OpenText.ps1 owns its own version check by reading version.txt next to itself and comparing to HKLM:\\SOFTWARE\\GE\\OpenText\\Installed; the runner always invokes the wrapper (cost: ~1s of PowerShell launch when up-to-date) so the version constant lives in exactly one place: dependencies/opentext/version.txt.",
"Name": "OpenText HostExplorer ShopFloor",
"Installer": "opentext\\Setup-OpenText.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Setup-OpenText.log",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "UDC_Setup.exe spawns a hidden WPF window (UDC.exe) after install and never exits, so the runner needs KillAfterDetection: true to terminate UDC_Setup.exe + UDC.exe once the registry detection passes. This is an OPT-IN flag - normal installers should NOT set it because killing msiexec mid-install leaves msiserver holding the install mutex and the next msiexec call returns 1618 (Oracle hit this exact bug).",
"Name": "UDC",
"Installer": "UDC_Setup.exe",
"Type": "EXE",
"InstallArgs": "\"West Jefferson\" -9999",
"KillAfterDetection": true,
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\UDC",
"PCTypes": ["gea-shopfloor-collections"],
"PCTypesStrict": true,
"_pcTypesNote": "UDC = the C in 'collections'. nocollections does NOT collect data so MUST NOT install UDC. PCTypesStrict bypasses the alias-expansion matcher so a nocollections PC's myNames (which transitively contains gea-shopfloor-collections via the Standard group) still won't match this entry."
},
{
"_comment": "Display kiosk app (Lobby Display or Dashboard). Install-KioskApp.cmd wrapper reads C:\\Enrollment\\display-type.txt to determine which installer to run. Both GEAerospaceLobbyDisplaySetup.exe and GEAerospaceDashboardSetup.exe must be staged in the display\\ subtree alongside the wrapper. Inno Setup /VERYSILENT is idempotent so no detection needed.",
"Name": "Display Kiosk App",
"Installer": "display\\Install-KioskApp.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Dashboard-install.log",
"PCTypes": ["Display"]
},
{
"_comment": "WJF Defect Tracker - replaces old ClickOnce deployment. MSI creates desktop + Start Menu shortcuts. Enforcer on SFLD share handles version updates post-imaging. TARGETDIR explicit because VS deployment MSI defaults to random path without it.",
"Name": "WJF Defect Tracker",
"Installer": "WJF_Defect_Tracker.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ALLUSERS=1 REBOOT=ReallySuppress TARGETDIR=\"C:\\Program Files (x86)\\WJF_Defect_Tracker\"",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\WJF_Defect_Tracker\\Defect_Tracker.exe",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "Shopfloor Standard serial-port drivers: StarTech PCIe serial adapter (MosChip-based) + Prolific PL2303 USB-to-serial. Install-Drivers.cmd runs pnputil /add-driver with /subdirs /install so every bundled INF under drivers/ lands in the Windows driver store and auto-binds to matching hardware present now or plugged in later. Installed on every PC type (PCTypes ['*']) because serial hardware turns up across bays; a serial driver on a PC without the hardware is harmless - it just sits in the driver store until matching hardware is plugged in.",
"Name": "Shopfloor Serial Drivers",
"Installer": "drivers\\Install-Drivers.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Install-Drivers.log",
"DetectionMethod": "File",
"DetectionPath": "C:\\ProgramData\\PXEDrivers\\drivers-installed.marker",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "HP universal print driver, staged at imaging so a bay comes off the line able to build an HP queue without waiting on the SFLD share. Set-ShopdbPrinters.ps1 creates queues against drivers that are already present and SKIPS any that are not, so without this a freshly imaged bay silently gets no printers until a later enforcement cycle tops it up. NO WAVE GATE HERE, deliberately: waves exist because ~300 bays share one runtime share, whereas imaging runs a handful of bays at a time on the isolated PXE LAN that already moves multi-GB WIMs. Detection is the SPOOLER's driver key, not pnputil - pnputil only proves the package reached the driver store, and Get-PrinterDriver (what Set-ShopdbPrinters consults) reads the spooler, so a pnputil check goes green on a half-install. Payload is NOT in git: stage printer-drivers/ onto the PXE share like the other installer payloads.",
"Name": "ShopDB Printer Driver - HP Universal PS",
"Installer": "printer-drivers\\Install-ShopdbPrinterDrivers.ps1",
"Type": "PS1",
"InstallArgs": "-Only 'HP Universal Printing PS'",
"LogFile": "C:\\Logs\\PreInstall\\printer-drivers.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SYSTEM\\CurrentControlSet\\Control\\Print\\Environments\\Windows x64\\Drivers\\Version-3\\HP Universal Printing PS",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "Xerox universal print driver. Same reasoning as the HP entry above. These two universals are 100 MB combined and resolve the overwhelming majority of the fleet's printers; the four device-specific drivers (DesignJet, Zebra ZT411, Epson C3500, FARGO card printer) are another 126 MB and are deliberately NOT staged at imaging - they belong only on the bays that have that hardware, and those bays pick them up from the runtime manifest on their next enforcement cycle.",
"Name": "ShopDB Printer Driver - Xerox Global PCL6",
"Installer": "printer-drivers\\Install-ShopdbPrinterDrivers.ps1",
"Type": "PS1",
"InstallArgs": "-Only 'Xerox Global Print Driver PCL6'",
"LogFile": "C:\\Logs\\PreInstall\\printer-drivers.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SYSTEM\\CurrentControlSet\\Control\\Print\\Environments\\Windows x64\\Drivers\\Version-3\\Xerox Global Print Driver PCL6",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
}
]
}