Files
pxe-server/playbook/startnet.cmd
cproudlock 37357eee43 Shopfloor images: add Wax/Trace + Keyence per-model variants
Wax/Trace (gea-shopfloor-waxtrace):
- captured/ holds master FormTracePak v6.0 state (Program Files reg dump
  gzipped, ARP entries) taken from a win11 VM where the CD-ROM-bound VB6
  wrapper was driven to completion. xcopy + reg-import replays the install
  on real bays without running the wrapper itself.
- 09-Setup-WaxAndTrace.ps1 rewrites the stub: installs prereqs via manifest
  (VC++ 2008/2017 x86+x64, Sentinel HASP), expands the captured zips into
  C:\Program Files (x86)\MitutoyoApp + C:\MitutoyoApp, imports the reg
  hive, then mounts the bay's per-machine cal ISO (matched by asset tag
  in machine-number.txt) and runs its Setup.exe.
- waxtrace-manifest.json lists the 5 prereqs with InstallShield-style
  silent flags verified on the win11 VM.
- sync-waxtrace.sh ships captured-binary/ + prereqs + cal ISOs from
  /home/camp/pxe-images/iso/mitutoyo-cal/ to
  /srv/samba/enrollment/installers-post/waxtrace/ on the PXE box.
- select-waxtrace-asset.ps1 arrow-key bay picker for WinPE (parses
  INDEX.csv from the cal share, offers "Other (new bay)" fallback).
- startnet.cmd: prompt_waxtrace_asset prompt, skip_waxtrace_stage xcopy
  block (mirrors :skip_cmm_stage), machine-number.txt write covers bay
  asset tag (WJRP*).

Keyence (gea-shopfloor-keyence) - now multi-model:
- vr3000/manifest.json + vr5000/manifest.json + vr6000/manifest.json
  (current single-model VR-6000 moved into vr6000/ subdir). Each ships
  the model's MSI silent-install + DetectionPath via ProductCode.
  Big payloads (Data1.cab, Data11.cab) gitignored, staged via
  sync-keyence.sh from /home/camp/pxe-images/iso/keyence/.
- 09-Setup-Keyence.ps1 dispatches by C:\Enrollment\keyence-model.txt
  (written by startnet.cmd in :keyence_submenu) and points
  InstallerRoot at C:\KeyenceInstall\<model>. DXSETUP probe widened
  to all three Program Files paths (VR-3000 G2, VR-5000, VR-6000).
- startnet.cmd: :keyence_submenu picks vr3000/vr5000/vr6000,
  :skip_keyence_stage xcopy block selectively stages chosen model bundle,
  pc-subtype.txt also written = drops directly into existing GE-Enforce
  PCSubType wiring (looks for gea-shopfloor-keyence-<model>\manifest.json
  on the tsgwp00525 share for ongoing enforcement, no dispatcher change
  needed).
- sync-keyence.sh mirrors sync-waxtrace.sh pattern.

Verified silent MSI install for VR-3000 G2 v2.5.0 and VR-5000 v3.3.1 on
the win11 VM 2026-05-18 with /qn /norestart ALLUSERS=1 REBOOT=ReallySuppress
TRANSFORMS=1033.mst. boot.wim on 172.16.9.1 wimupdate'd with the new
startnet.cmd.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-18 16:34:20 -04:00

485 lines
19 KiB
Batchfile

@echo off
echo Please wait while 'WinPE' is being processed. This may take a few seconds.
wpeinit
powercfg /s 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c
REM --- Wait for network (DHCP may take a moment after wpeinit) ---
echo Waiting for network...
:wait_net
ping -n 2 172.16.9.1 >NUL 2>&1
if errorlevel 1 goto wait_net
echo Network ready.
REM --- BIOS update check (runs before imaging menu) ---
REM Mounts [winpeapps_bios] share. CRITICAL: do NOT call check-bios.cmd
REM inside an `if exist (...)` parens block - CMD's variable scoping for
REM CALLed scripts inside parens does not propagate BIOS_STATUS back to
REM this script reliably. Use goto-flow instead so the CALL runs at the
REM top scope and BIOS_STATUS persists.
set BIOS_STATUS=No BIOS check (share unavailable)
net use B: \\172.16.9.1\winpeapps_bios /user:pxe-upload pxe /persistent:no 2>NUL
if not exist B:\check-bios.cmd goto :bios_check_done
echo.
echo Checking for BIOS updates...
call B:\check-bios.cmd
:bios_check_done
net use B: /delete 2>NUL
:menu
cls
echo.
echo ========================================
echo WinPE Setup Menu
echo ========================================
echo Firmware: %BIOS_STATUS%
echo.
echo Please select an option:
echo.
echo 1. GEA Standard
echo 2. GEA Engineer
echo 3. GEA Shopfloor (sub-menu)
echo 4. GE Standard
echo 5. GE Engineer
echo 6. GE Shopfloor Lockdown
echo 7. GE Shopfloor MCE
echo.
echo ========================================
echo.
set /p choice=Enter your choice (1-7):
REM --- Shopfloor images (3,6,7) need GCCH enrollment + (for 3) PC-type sub-menu.
REM Choice 3 = GEA Shopfloor: drill into sub-menu first to pick the gea-shopfloor-*
REM sub-category, THEN the office menu, THEN machine number for collections+nocollections.
set PPKG=
if "%choice%"=="3" goto gea_shopfloor_submenu
if "%choice%"=="6" goto enroll_menu
if "%choice%"=="7" goto enroll_menu
goto enroll_staged
:gea_shopfloor_submenu
cls
echo.
echo ========================================
echo GEA Shopfloor PC Sub-Type
echo ========================================
echo.
echo 1. Machine with Collections (eDNC + UDC + Plant Apps)
echo 2. Machine without Collections (eDNC + Plant Apps, no UDC)
echo 3. Common (Timeclock, Lab; WJ Shopfloor only)
echo 4. Keyence (VR-3000 / VR-5000 / VR-6000 microscope)
echo 5. CMM (Hexagon PC-DMIS + Protect Viewer)
echo 6. Genspect
echo 7. Heattreat (placeholder)
echo 8. Wax and Trace
echo 9. Display (kiosk dashboard)
echo.
set PCTYPE=
set /p ges_choice=Enter your choice (1-9):
if "%ges_choice%"=="1" set PCTYPE=gea-shopfloor-collections
if "%ges_choice%"=="2" set PCTYPE=gea-shopfloor-nocollections
if "%ges_choice%"=="3" set PCTYPE=gea-shopfloor-common
if "%ges_choice%"=="4" set PCTYPE=gea-shopfloor-keyence
if "%ges_choice%"=="5" set PCTYPE=gea-shopfloor-cmm
if "%ges_choice%"=="6" set PCTYPE=gea-shopfloor-genspect
if "%ges_choice%"=="7" set PCTYPE=gea-shopfloor-heattreat
if "%ges_choice%"=="8" set PCTYPE=gea-shopfloor-waxtrace
if "%ges_choice%"=="9" set PCTYPE=gea-shopfloor-display
if "%PCTYPE%"=="" goto gea_shopfloor_submenu
if "%PCTYPE%"=="gea-shopfloor-display" goto display_submenu
if "%PCTYPE%"=="gea-shopfloor-keyence" goto keyence_submenu
goto enroll_menu
:keyence_submenu
cls
echo.
echo ========================================
echo Keyence Model
echo ========================================
echo.
echo 1. VR-3000 G2 (older microscope/profilometer line)
echo 2. VR-5000 (mid-range)
echo 3. VR-6000 (current line)
echo.
set KEYENCEMODEL=
set /p kmod_choice=Enter your choice (1-3):
if "%kmod_choice%"=="1" set KEYENCEMODEL=vr3000
if "%kmod_choice%"=="2" set KEYENCEMODEL=vr5000
if "%kmod_choice%"=="3" set KEYENCEMODEL=vr6000
if "%KEYENCEMODEL%"=="" goto keyence_submenu
echo Keyence model: %KEYENCEMODEL%
goto enroll_menu
:display_submenu
cls
echo.
echo ========================================
echo Display Kiosk Sub-Type
echo ========================================
echo.
echo 1. Dashboard (shop floor metrics dashboard)
echo 2. Lobby Display (lobby information screen)
echo.
set DISPLAYTYPE=
set /p disp_choice=Enter your choice (1-2):
if "%disp_choice%"=="1" set DISPLAYTYPE=Dashboard
if "%disp_choice%"=="2" set DISPLAYTYPE=Lobby
if "%DISPLAYTYPE%"=="" goto display_submenu
goto enroll_menu
:enroll_menu
cls
echo.
echo ========================================
echo GCCH Enrollment Profile
echo ========================================
echo.
echo 1. No Office
echo 2. Standard Office (x86)
echo 3. Standard Office (x64)
echo 4. Pro Plus Office (x86) with Access
echo 5. Pro Plus Office (x64) with Access
echo 6. Skip enrollment
echo.
set /p enroll=Enter your choice (1-6):
REM --- PPKG configuration (constructed at menu time, see docs) ---
REM Vendor ships one source PPKG; we construct the BPRT-tagged filename
REM by filling in Office, Region, Expiry, Version on the target copy.
REM Update SOURCE_PPKG + PPKG_VER when a new PPKG is released.
set SOURCE_PPKG=GCCH_Prod_SFLD_v4.14.ppkg
set PPKG_VER=v4.14
set PPKG_EXP=20260831
set REGION=US
set OFFICE=
if "%enroll%"=="1" set OFFICE=NoOffice
if "%enroll%"=="2" set OFFICE=StdOffice-x86
if "%enroll%"=="3" set OFFICE=StdOffice-x64
if "%enroll%"=="4" set OFFICE=ProPlusOffice-x86
if "%enroll%"=="5" set OFFICE=ProPlusOffice-x64
if "%enroll%"=="6" set OFFICE=
if "%enroll%"=="" goto enroll_menu
set PPKG=
if not "%OFFICE%"=="" set PPKG=GCCH_Prod_SFLD_%OFFICE%_%REGION%_Exp_%PPKG_EXP%_%PPKG_VER%.ppkg
REM --- 2026-05-04 rename reorg: PCTYPE is set by gea_shopfloor_submenu above
REM (single string, e.g. gea-shopfloor-collections). pc-subtype.txt is no
REM longer written. DISPLAYTYPE IS still written (display-type.txt) when
REM PCTYPE=gea-shopfloor-display because Install-KioskApp.cmd needs Lobby
REM vs Dashboard to choose installer + Get-PCProfile builds Display-{type}
REM profile key.
set PCSUBTYPE=
REM --- Machine number / asset tag (only PC types that key per-machine config) ---
REM collections + nocollections = 4-digit machine number for shopfloor identification.
REM waxtrace = asset tag like WJRP2335 used to match per-machine cal ISO during
REM 09-Setup-WaxAndTrace.ps1. Cal ISO files are named
REM CAL-{asset_tag}_serial-*_probe-*.iso.
set MACHINENUM=9999
if /i "%PCTYPE%"=="gea-shopfloor-collections" goto prompt_machinenum
if /i "%PCTYPE%"=="gea-shopfloor-nocollections" goto prompt_machinenum
if /i "%PCTYPE%"=="gea-shopfloor-waxtrace" goto prompt_waxtrace_asset
goto skip_machinenum
:prompt_machinenum
echo.
set /p MACHINENUM=Enter machine number (digits, or Enter for 9999):
if "%MACHINENUM%"=="" set MACHINENUM=9999
echo Machine number: %MACHINENUM%
goto skip_machinenum
:prompt_waxtrace_asset
echo.
echo Wax/Trace bays use the asset tag (e.g. WJRP2335) to pick the right
echo calibration ISO during shopfloor setup.
set /p MACHINENUM=Enter asset tag (e.g. WJRP2335):
if "%MACHINENUM%"=="" (
echo WARNING: no asset tag entered - calibration apply will be skipped.
set MACHINENUM=
)
echo Asset tag: %MACHINENUM%
:skip_machinenum
REM --- Map enrollment share early (kept open for copy after imaging) ---
set NEED_ENROLL=0
if not "%PPKG%"=="" set NEED_ENROLL=1
if not "%PCTYPE%"=="" set NEED_ENROLL=1
if "%NEED_ENROLL%"=="0" goto enroll_staged
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no
if "%PPKG%"=="" goto enroll_staged
if not exist "Y:\ppkgs\%SOURCE_PPKG%" (
echo WARNING: %SOURCE_PPKG% not found on server. Enrollment will be skipped.
set PPKG=
)
:enroll_staged
echo. > X:\Boot.tag
if "%choice%"=="1" goto gea-standard
if "%choice%"=="2" goto gea-engineer
if "%choice%"=="3" goto gea-shopfloor
if "%choice%"=="4" goto ge-standard
if "%choice%"=="5" goto ge-engineer
if "%choice%"=="6" goto ge-shopfloor-lockdown
if "%choice%"=="7" goto ge-shopfloor-mce
echo Invalid choice. Please try again.
pause
goto menu
:gea-standard
echo.
echo Starting GEA Standard setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\gea-standard /user:pxe-upload pxe /persistent:no
goto end
:gea-engineer
echo.
echo Starting GEA Engineer setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\gea-engineer /user:pxe-upload pxe /persistent:no
goto end
:gea-shopfloor
echo.
echo Starting GEA Shopfloor setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\gea-shopfloor /user:pxe-upload pxe /persistent:no
goto end
:ge-standard
echo.
echo Starting GE Standard setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\ge-standard /user:pxe-upload pxe /persistent:no
goto end
:ge-engineer
echo.
echo Starting GE Engineer setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\ge-engineer /user:pxe-upload pxe /persistent:no
goto end
:ge-shopfloor-lockdown
echo.
echo Starting GE Shopfloor Lockdown setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\ge-shopfloor-lockdown /user:pxe-upload pxe /persistent:no
goto end
:ge-shopfloor-mce
echo.
echo Starting GE Shopfloor MCE setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\172.16.9.1\winpeapps\ge-shopfloor-mce /user:pxe-upload pxe /persistent:no
goto end
:end
echo.
REM --- Push initial "WinPE staging" status to PXE webapp ---
REM Externalized to Y:\scripts\winpe-status-push.ps1 so future edits don't
REM require a boot.wim rebuild. Best-effort; the script logs to
REM X:\Windows\Temp\winpe-status-push.log and swallows all errors.
if exist "Y:\scripts\winpe-status-push.ps1" (
powershell -NoProfile -ExecutionPolicy Bypass -File "Y:\scripts\winpe-status-push.ps1"
)
echo Waiting for PESetup.exe to start...
:wait_start
ping -n 3 127.0.0.1 >NUL
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
if errorlevel 1 goto wait_start
echo PESetup.exe is running. Waiting for imaging to complete...
REM --- Copy enrollment package and shopfloor setup as soon as Windows partition appears ---
if "%PPKG%"=="" if "%PCTYPE%"=="" goto wait_finish
echo Waiting for Windows partition at W: ...
:wait_enroll
ping -n 11 127.0.0.1 >NUL
if not exist W:\Windows\System32\config\system goto wait_enroll
echo Found Windows at W:
mkdir W:\Enrollment 2>NUL
REM --- Copy site config (drives site-specific values in all setup scripts) ---
if exist "Y:\config\site-config.json" (
copy /Y "Y:\config\site-config.json" "W:\Enrollment\site-config.json"
echo Copied site-config.json.
) else (
echo WARNING: site-config.json not found on enrollment share.
)
REM --- Copy PPKG if selected (renames from SOURCE to BPRT-tagged filename) ---
if "%PPKG%"=="" goto copy_pctype
copy /Y "Y:\ppkgs\%SOURCE_PPKG%" "W:\Enrollment\%PPKG%"
if errorlevel 1 (
echo WARNING: Failed to copy enrollment package.
goto copy_pctype
)
copy /Y "Y:\scripts\run-enrollment.ps1" "W:\Enrollment\run-enrollment.ps1"
copy /Y "Y:\scripts\wait-for-internet.ps1" "W:\Enrollment\wait-for-internet.ps1"
copy /Y "Y:\scripts\migrate-to-wifi.ps1" "W:\Enrollment\migrate-to-wifi.ps1"
REM --- Create enroll.cmd at drive root as manual fallback ---
> W:\enroll.cmd (
echo @echo off
echo echo Waiting for network...
echo :waitnet
echo ping -n 2 8.8.8.8 ^>NUL 2^>^&1
echo if errorlevel 1 goto waitnet
echo echo Network connected. Running enrollment...
echo powershell.exe -ExecutionPolicy Bypass -File "C:\run-enrollment.ps1"
)
echo Manual fallback created at W:\enroll.cmd
:copy_pctype
REM --- Copy shopfloor PC type setup scripts ---
if "%PCTYPE%"=="" goto cleanup_enroll
echo %PCTYPE%> W:\Enrollment\pc-type.txt
REM 2026-05-04 rename reorg: pc-subtype.txt no longer written.
REM display-type.txt IS still written for gea-shopfloor-display because
REM Install-KioskApp.cmd reads it to pick Lobby vs Dashboard installer
REM and Get-PCProfile.ps1 reads it to build the Display-{type} profile key.
if not "%DISPLAYTYPE%"=="" echo %DISPLAYTYPE%> W:\Enrollment\display-type.txt
if not "%MACHINENUM%"=="" echo %MACHINENUM%> W:\Enrollment\machine-number.txt
REM Keyence model goes to BOTH keyence-model.txt (read by 09-Setup-Keyence) AND
REM pc-subtype.txt (read by GE-Enforce for per-model dispatch via existing
REM PCSubType wiring: looks for gea-shopfloor-keyence-<model>\manifest.json on share).
if not "%KEYENCEMODEL%"=="" (
echo %KEYENCEMODEL%> W:\Enrollment\keyence-model.txt
echo %KEYENCEMODEL%> W:\Enrollment\pc-subtype.txt
)
copy /Y "Y:\shopfloor-setup\Run-ShopfloorSetup.ps1" "W:\Enrollment\Run-ShopfloorSetup.ps1"
REM --- Always copy Shopfloor baseline scripts ---
mkdir W:\Enrollment\shopfloor-setup 2>NUL
copy /Y "Y:\shopfloor-setup\backup_lockdown.bat" "W:\Enrollment\shopfloor-setup\backup_lockdown.bat"
if exist "Y:\shopfloor-setup\Shopfloor" (
mkdir W:\Enrollment\shopfloor-setup\Shopfloor 2>NUL
xcopy /E /Y /I "Y:\shopfloor-setup\Shopfloor" "W:\Enrollment\shopfloor-setup\Shopfloor\"
echo Copied Shopfloor baseline setup files.
)
REM --- Always copy common/ (cross-PC-type GE-Enforce dispatcher + lib live here post-v2) ---
if exist "Y:\shopfloor-setup\common" (
mkdir W:\Enrollment\shopfloor-setup\common 2>NUL
xcopy /E /Y /I "Y:\shopfloor-setup\common" "W:\Enrollment\shopfloor-setup\common\"
echo Copied common setup files.
)
REM --- Copy _ntlars-backups (147 per-bay .reg files restored by gea-shopfloor-{collections,nocollections}\03-RestoreEDncConfig.ps1) ---
REM Same root level as common/, referenced by 03-RestoreEDncConfig.ps1 via Join-Path $PSScriptRoot '..\_ntlars-backups'.
if exist "Y:\shopfloor-setup\_ntlars-backups" (
mkdir W:\Enrollment\shopfloor-setup\_ntlars-backups 2>NUL
xcopy /E /Y /I "Y:\shopfloor-setup\_ntlars-backups" "W:\Enrollment\shopfloor-setup\_ntlars-backups\"
echo Copied _ntlars-backups.
)
REM --- Copy type-specific scripts on top of baseline ---
if exist "Y:\shopfloor-setup\%PCTYPE%" (
mkdir "W:\Enrollment\shopfloor-setup\%PCTYPE%" 2>NUL
xcopy /E /Y /I "Y:\shopfloor-setup\%PCTYPE%" "W:\Enrollment\shopfloor-setup\%PCTYPE%\"
echo Copied %PCTYPE% setup files.
) else (
echo WARNING: No setup files found for PC type %PCTYPE%.
)
REM --- Stage preinstall bundle (apps installed locally to save Azure bandwidth) ---
if exist "Y:\pre-install\preinstall.json" (
mkdir W:\PreInstall 2>NUL
mkdir W:\PreInstall\installers 2>NUL
copy /Y "Y:\pre-install\preinstall.json" "W:\PreInstall\preinstall.json"
if exist "Y:\pre-install\installers" (
xcopy /E /Y /I "Y:\pre-install\installers" "W:\PreInstall\installers\"
echo Staged preinstall bundle to W:\PreInstall.
) else (
echo WARNING: Y:\pre-install\installers not found - preinstall.json staged without installers.
)
if exist "Y:\pre-install\udc-backups" (
xcopy /E /Y /I "Y:\pre-install\udc-backups" "W:\PreInstall\udc-backups\"
echo Staged UDC settings backups to W:\PreInstall\udc-backups.
)
) else (
echo No preinstall bundle on PXE server - skipping.
)
REM --- Stage CMM bootstrap bundle (CMM-type PCs only) ---
REM Copies the Hexagon installer bundle (~1.9 GB) from the PXE server enrollment
REM share onto the target disk so 09-Setup-CMM.ps1 can install from local disk.
REM The tsgwp00525 SFLD share that holds the canonical copy is not yet reachable
REM during shopfloor-setup (Azure DSC provisions those creds later), so this
REM bootstrap exists to get the first-install through. Post-imaging, the
REM unified GE-Enforce dispatcher takes over from the share for ongoing updates.
if /i not "%PCTYPE%"=="gea-shopfloor-cmm" goto skip_cmm_stage
if exist "Y:\installers-post\cmm\cmm-manifest.json" (
mkdir W:\CMM-Install 2>NUL
xcopy /E /Y /I "Y:\installers-post\cmm" "W:\CMM-Install\"
echo Staged CMM bootstrap to W:\CMM-Install.
) else (
echo WARNING: Y:\cmm-installers not found - CMM PC cannot install Hexagon apps at imaging time.
)
:skip_cmm_stage
REM --- Stage Keyence per-model bootstrap bundle (Keyence PCs only) ---
REM Copies only the selected model's MSI + Data cabs from the PXE enrollment
REM share to the target disk. installers-post/keyence/<model>/ contains:
REM manifest.json
REM installers/{MSI, Data1.cab, [Data11.cab for vr3000], 1033.mst}
REM drivers/ (vr6000 only - older external .inf; vr3000/vr5000 drivers
REM are embedded in their MSIs)
REM 09-Setup-Keyence.ps1 reads C:\Enrollment\keyence-model.txt to know which.
if /i not "%PCTYPE%"=="gea-shopfloor-keyence" goto skip_keyence_stage
if "%KEYENCEMODEL%"=="" goto skip_keyence_stage
if exist "Y:\installers-post\keyence\%KEYENCEMODEL%\manifest.json" (
mkdir W:\KeyenceInstall 2>NUL
mkdir W:\KeyenceInstall\%KEYENCEMODEL% 2>NUL
xcopy /E /Y /I "Y:\installers-post\keyence\%KEYENCEMODEL%" "W:\KeyenceInstall\%KEYENCEMODEL%\"
echo Staged Keyence %KEYENCEMODEL% bootstrap to W:\KeyenceInstall\%KEYENCEMODEL%\.
) else (
echo WARNING: Y:\installers-post\keyence\%KEYENCEMODEL% not found - Keyence %KEYENCEMODEL% cannot install at imaging time.
)
:skip_keyence_stage
REM --- Stage WaxTrace bootstrap bundle (wax/trace gea-shopfloor-waxtrace only) ---
REM Copies the FormTracePak master capture (~110 MB compressed) + HASP +
REM VC++ redists + per-machine cal ISOs from the enrollment share onto the
REM target disk so 09-Setup-WaxAndTrace.ps1 can install FormTracePak via
REM xcopy + reg-import (bypassing Mitutoyo's CD-ROM-bound VB6 wrapper).
if /i not "%PCTYPE%"=="gea-shopfloor-waxtrace" goto skip_waxtrace_stage
if exist "Y:\installers-post\waxtrace\waxtrace-manifest.json" (
mkdir W:\WaxTrace-Install 2>NUL
xcopy /E /Y /I "Y:\installers-post\waxtrace" "W:\WaxTrace-Install\"
echo Staged WaxTrace bootstrap to W:\WaxTrace-Install.
) else (
echo WARNING: Y:\installers-post\waxtrace not found - WaxTrace PC cannot install FormTracePak at imaging time.
)
:skip_waxtrace_stage
:pctype_done
REM --- BIOS update sub-stage push (fires AFTER W: copies complete) ---
REM check-bios.cmd drops X:\bios-fired.flag iff it actually flashed or
REM staged a firmware update. Reading the flag file is more reliable than
REM scanning BIOS_STATUS for substrings (caret escaping inside quoted SET
REM is subtle in WinPE cmd.exe). Push must happen before Y: cleanup since
REM the push script lives on the share.
if exist X:\bios-fired.flag (
if exist "Y:\scripts\winpe-status-push.ps1" (
powershell -NoProfile -ExecutionPolicy Bypass -File "Y:\scripts\winpe-status-push.ps1" -CurrentStage "WinPE: BIOS firmware update"
)
)
:cleanup_enroll
net use Y: /delete 2>NUL
:wait_finish
ping -n 11 127.0.0.1 >NUL
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
if not errorlevel 1 goto wait_finish
echo.
echo Imaging complete. Rebooting in 15 seconds...
echo Press Ctrl+C to cancel.
ping -n 16 127.0.0.1 >NUL
wpeutil reboot