Wax/Trace (gea-shopfloor-waxtrace): - captured/ holds master FormTracePak v6.0 state (Program Files reg dump gzipped, ARP entries) taken from a win11 VM where the CD-ROM-bound VB6 wrapper was driven to completion. xcopy + reg-import replays the install on real bays without running the wrapper itself. - 09-Setup-WaxAndTrace.ps1 rewrites the stub: installs prereqs via manifest (VC++ 2008/2017 x86+x64, Sentinel HASP), expands the captured zips into C:\Program Files (x86)\MitutoyoApp + C:\MitutoyoApp, imports the reg hive, then mounts the bay's per-machine cal ISO (matched by asset tag in machine-number.txt) and runs its Setup.exe. - waxtrace-manifest.json lists the 5 prereqs with InstallShield-style silent flags verified on the win11 VM. - sync-waxtrace.sh ships captured-binary/ + prereqs + cal ISOs from /home/camp/pxe-images/iso/mitutoyo-cal/ to /srv/samba/enrollment/installers-post/waxtrace/ on the PXE box. - select-waxtrace-asset.ps1 arrow-key bay picker for WinPE (parses INDEX.csv from the cal share, offers "Other (new bay)" fallback). - startnet.cmd: prompt_waxtrace_asset prompt, skip_waxtrace_stage xcopy block (mirrors :skip_cmm_stage), machine-number.txt write covers bay asset tag (WJRP*). Keyence (gea-shopfloor-keyence) - now multi-model: - vr3000/manifest.json + vr5000/manifest.json + vr6000/manifest.json (current single-model VR-6000 moved into vr6000/ subdir). Each ships the model's MSI silent-install + DetectionPath via ProductCode. Big payloads (Data1.cab, Data11.cab) gitignored, staged via sync-keyence.sh from /home/camp/pxe-images/iso/keyence/. - 09-Setup-Keyence.ps1 dispatches by C:\Enrollment\keyence-model.txt (written by startnet.cmd in :keyence_submenu) and points InstallerRoot at C:\KeyenceInstall\<model>. DXSETUP probe widened to all three Program Files paths (VR-3000 G2, VR-5000, VR-6000). - startnet.cmd: :keyence_submenu picks vr3000/vr5000/vr6000, :skip_keyence_stage xcopy block selectively stages chosen model bundle, pc-subtype.txt also written = drops directly into existing GE-Enforce PCSubType wiring (looks for gea-shopfloor-keyence-<model>\manifest.json on the tsgwp00525 share for ongoing enforcement, no dispatcher change needed). - sync-keyence.sh mirrors sync-waxtrace.sh pattern. Verified silent MSI install for VR-3000 G2 v2.5.0 and VR-5000 v3.3.1 on the win11 VM 2026-05-18 with /qn /norestart ALLUSERS=1 REBOOT=ReallySuppress TRANSFORMS=1033.mst. boot.wim on 172.16.9.1 wimupdate'd with the new startnet.cmd. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
485 lines
19 KiB
Batchfile
485 lines
19 KiB
Batchfile
@echo off
|
|
echo Please wait while 'WinPE' is being processed. This may take a few seconds.
|
|
wpeinit
|
|
powercfg /s 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c
|
|
|
|
REM --- Wait for network (DHCP may take a moment after wpeinit) ---
|
|
echo Waiting for network...
|
|
:wait_net
|
|
ping -n 2 172.16.9.1 >NUL 2>&1
|
|
if errorlevel 1 goto wait_net
|
|
echo Network ready.
|
|
|
|
REM --- BIOS update check (runs before imaging menu) ---
|
|
REM Mounts [winpeapps_bios] share. CRITICAL: do NOT call check-bios.cmd
|
|
REM inside an `if exist (...)` parens block - CMD's variable scoping for
|
|
REM CALLed scripts inside parens does not propagate BIOS_STATUS back to
|
|
REM this script reliably. Use goto-flow instead so the CALL runs at the
|
|
REM top scope and BIOS_STATUS persists.
|
|
set BIOS_STATUS=No BIOS check (share unavailable)
|
|
net use B: \\172.16.9.1\winpeapps_bios /user:pxe-upload pxe /persistent:no 2>NUL
|
|
if not exist B:\check-bios.cmd goto :bios_check_done
|
|
echo.
|
|
echo Checking for BIOS updates...
|
|
call B:\check-bios.cmd
|
|
:bios_check_done
|
|
net use B: /delete 2>NUL
|
|
|
|
:menu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo WinPE Setup Menu
|
|
echo ========================================
|
|
echo Firmware: %BIOS_STATUS%
|
|
echo.
|
|
echo Please select an option:
|
|
echo.
|
|
echo 1. GEA Standard
|
|
echo 2. GEA Engineer
|
|
echo 3. GEA Shopfloor (sub-menu)
|
|
echo 4. GE Standard
|
|
echo 5. GE Engineer
|
|
echo 6. GE Shopfloor Lockdown
|
|
echo 7. GE Shopfloor MCE
|
|
echo.
|
|
echo ========================================
|
|
echo.
|
|
set /p choice=Enter your choice (1-7):
|
|
|
|
REM --- Shopfloor images (3,6,7) need GCCH enrollment + (for 3) PC-type sub-menu.
|
|
REM Choice 3 = GEA Shopfloor: drill into sub-menu first to pick the gea-shopfloor-*
|
|
REM sub-category, THEN the office menu, THEN machine number for collections+nocollections.
|
|
set PPKG=
|
|
if "%choice%"=="3" goto gea_shopfloor_submenu
|
|
if "%choice%"=="6" goto enroll_menu
|
|
if "%choice%"=="7" goto enroll_menu
|
|
goto enroll_staged
|
|
|
|
:gea_shopfloor_submenu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo GEA Shopfloor PC Sub-Type
|
|
echo ========================================
|
|
echo.
|
|
echo 1. Machine with Collections (eDNC + UDC + Plant Apps)
|
|
echo 2. Machine without Collections (eDNC + Plant Apps, no UDC)
|
|
echo 3. Common (Timeclock, Lab; WJ Shopfloor only)
|
|
echo 4. Keyence (VR-3000 / VR-5000 / VR-6000 microscope)
|
|
echo 5. CMM (Hexagon PC-DMIS + Protect Viewer)
|
|
echo 6. Genspect
|
|
echo 7. Heattreat (placeholder)
|
|
echo 8. Wax and Trace
|
|
echo 9. Display (kiosk dashboard)
|
|
echo.
|
|
set PCTYPE=
|
|
set /p ges_choice=Enter your choice (1-9):
|
|
if "%ges_choice%"=="1" set PCTYPE=gea-shopfloor-collections
|
|
if "%ges_choice%"=="2" set PCTYPE=gea-shopfloor-nocollections
|
|
if "%ges_choice%"=="3" set PCTYPE=gea-shopfloor-common
|
|
if "%ges_choice%"=="4" set PCTYPE=gea-shopfloor-keyence
|
|
if "%ges_choice%"=="5" set PCTYPE=gea-shopfloor-cmm
|
|
if "%ges_choice%"=="6" set PCTYPE=gea-shopfloor-genspect
|
|
if "%ges_choice%"=="7" set PCTYPE=gea-shopfloor-heattreat
|
|
if "%ges_choice%"=="8" set PCTYPE=gea-shopfloor-waxtrace
|
|
if "%ges_choice%"=="9" set PCTYPE=gea-shopfloor-display
|
|
if "%PCTYPE%"=="" goto gea_shopfloor_submenu
|
|
if "%PCTYPE%"=="gea-shopfloor-display" goto display_submenu
|
|
if "%PCTYPE%"=="gea-shopfloor-keyence" goto keyence_submenu
|
|
goto enroll_menu
|
|
|
|
:keyence_submenu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo Keyence Model
|
|
echo ========================================
|
|
echo.
|
|
echo 1. VR-3000 G2 (older microscope/profilometer line)
|
|
echo 2. VR-5000 (mid-range)
|
|
echo 3. VR-6000 (current line)
|
|
echo.
|
|
set KEYENCEMODEL=
|
|
set /p kmod_choice=Enter your choice (1-3):
|
|
if "%kmod_choice%"=="1" set KEYENCEMODEL=vr3000
|
|
if "%kmod_choice%"=="2" set KEYENCEMODEL=vr5000
|
|
if "%kmod_choice%"=="3" set KEYENCEMODEL=vr6000
|
|
if "%KEYENCEMODEL%"=="" goto keyence_submenu
|
|
echo Keyence model: %KEYENCEMODEL%
|
|
goto enroll_menu
|
|
|
|
:display_submenu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo Display Kiosk Sub-Type
|
|
echo ========================================
|
|
echo.
|
|
echo 1. Dashboard (shop floor metrics dashboard)
|
|
echo 2. Lobby Display (lobby information screen)
|
|
echo.
|
|
set DISPLAYTYPE=
|
|
set /p disp_choice=Enter your choice (1-2):
|
|
if "%disp_choice%"=="1" set DISPLAYTYPE=Dashboard
|
|
if "%disp_choice%"=="2" set DISPLAYTYPE=Lobby
|
|
if "%DISPLAYTYPE%"=="" goto display_submenu
|
|
goto enroll_menu
|
|
|
|
:enroll_menu
|
|
cls
|
|
echo.
|
|
echo ========================================
|
|
echo GCCH Enrollment Profile
|
|
echo ========================================
|
|
echo.
|
|
echo 1. No Office
|
|
echo 2. Standard Office (x86)
|
|
echo 3. Standard Office (x64)
|
|
echo 4. Pro Plus Office (x86) with Access
|
|
echo 5. Pro Plus Office (x64) with Access
|
|
echo 6. Skip enrollment
|
|
echo.
|
|
set /p enroll=Enter your choice (1-6):
|
|
|
|
REM --- PPKG configuration (constructed at menu time, see docs) ---
|
|
REM Vendor ships one source PPKG; we construct the BPRT-tagged filename
|
|
REM by filling in Office, Region, Expiry, Version on the target copy.
|
|
REM Update SOURCE_PPKG + PPKG_VER when a new PPKG is released.
|
|
set SOURCE_PPKG=GCCH_Prod_SFLD_v4.14.ppkg
|
|
set PPKG_VER=v4.14
|
|
set PPKG_EXP=20260831
|
|
set REGION=US
|
|
|
|
set OFFICE=
|
|
if "%enroll%"=="1" set OFFICE=NoOffice
|
|
if "%enroll%"=="2" set OFFICE=StdOffice-x86
|
|
if "%enroll%"=="3" set OFFICE=StdOffice-x64
|
|
if "%enroll%"=="4" set OFFICE=ProPlusOffice-x86
|
|
if "%enroll%"=="5" set OFFICE=ProPlusOffice-x64
|
|
if "%enroll%"=="6" set OFFICE=
|
|
if "%enroll%"=="" goto enroll_menu
|
|
|
|
set PPKG=
|
|
if not "%OFFICE%"=="" set PPKG=GCCH_Prod_SFLD_%OFFICE%_%REGION%_Exp_%PPKG_EXP%_%PPKG_VER%.ppkg
|
|
|
|
REM --- 2026-05-04 rename reorg: PCTYPE is set by gea_shopfloor_submenu above
|
|
REM (single string, e.g. gea-shopfloor-collections). pc-subtype.txt is no
|
|
REM longer written. DISPLAYTYPE IS still written (display-type.txt) when
|
|
REM PCTYPE=gea-shopfloor-display because Install-KioskApp.cmd needs Lobby
|
|
REM vs Dashboard to choose installer + Get-PCProfile builds Display-{type}
|
|
REM profile key.
|
|
set PCSUBTYPE=
|
|
|
|
REM --- Machine number / asset tag (only PC types that key per-machine config) ---
|
|
REM collections + nocollections = 4-digit machine number for shopfloor identification.
|
|
REM waxtrace = asset tag like WJRP2335 used to match per-machine cal ISO during
|
|
REM 09-Setup-WaxAndTrace.ps1. Cal ISO files are named
|
|
REM CAL-{asset_tag}_serial-*_probe-*.iso.
|
|
set MACHINENUM=9999
|
|
if /i "%PCTYPE%"=="gea-shopfloor-collections" goto prompt_machinenum
|
|
if /i "%PCTYPE%"=="gea-shopfloor-nocollections" goto prompt_machinenum
|
|
if /i "%PCTYPE%"=="gea-shopfloor-waxtrace" goto prompt_waxtrace_asset
|
|
goto skip_machinenum
|
|
:prompt_machinenum
|
|
echo.
|
|
set /p MACHINENUM=Enter machine number (digits, or Enter for 9999):
|
|
if "%MACHINENUM%"=="" set MACHINENUM=9999
|
|
echo Machine number: %MACHINENUM%
|
|
goto skip_machinenum
|
|
:prompt_waxtrace_asset
|
|
echo.
|
|
echo Wax/Trace bays use the asset tag (e.g. WJRP2335) to pick the right
|
|
echo calibration ISO during shopfloor setup.
|
|
set /p MACHINENUM=Enter asset tag (e.g. WJRP2335):
|
|
if "%MACHINENUM%"=="" (
|
|
echo WARNING: no asset tag entered - calibration apply will be skipped.
|
|
set MACHINENUM=
|
|
)
|
|
echo Asset tag: %MACHINENUM%
|
|
:skip_machinenum
|
|
|
|
REM --- Map enrollment share early (kept open for copy after imaging) ---
|
|
set NEED_ENROLL=0
|
|
if not "%PPKG%"=="" set NEED_ENROLL=1
|
|
if not "%PCTYPE%"=="" set NEED_ENROLL=1
|
|
if "%NEED_ENROLL%"=="0" goto enroll_staged
|
|
net use Y: \\172.16.9.1\enrollment /user:pxe-upload pxe /persistent:no
|
|
if "%PPKG%"=="" goto enroll_staged
|
|
if not exist "Y:\ppkgs\%SOURCE_PPKG%" (
|
|
echo WARNING: %SOURCE_PPKG% not found on server. Enrollment will be skipped.
|
|
set PPKG=
|
|
)
|
|
:enroll_staged
|
|
|
|
echo. > X:\Boot.tag
|
|
if "%choice%"=="1" goto gea-standard
|
|
if "%choice%"=="2" goto gea-engineer
|
|
if "%choice%"=="3" goto gea-shopfloor
|
|
if "%choice%"=="4" goto ge-standard
|
|
if "%choice%"=="5" goto ge-engineer
|
|
if "%choice%"=="6" goto ge-shopfloor-lockdown
|
|
if "%choice%"=="7" goto ge-shopfloor-mce
|
|
echo Invalid choice. Please try again.
|
|
pause
|
|
goto menu
|
|
|
|
:gea-standard
|
|
echo.
|
|
echo Starting GEA Standard setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\gea-standard /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:gea-engineer
|
|
echo.
|
|
echo Starting GEA Engineer setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\gea-engineer /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:gea-shopfloor
|
|
echo.
|
|
echo Starting GEA Shopfloor setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\gea-shopfloor /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:ge-standard
|
|
echo.
|
|
echo Starting GE Standard setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\ge-standard /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:ge-engineer
|
|
echo.
|
|
echo Starting GE Engineer setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\ge-engineer /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:ge-shopfloor-lockdown
|
|
echo.
|
|
echo Starting GE Shopfloor Lockdown setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\ge-shopfloor-lockdown /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:ge-shopfloor-mce
|
|
echo.
|
|
echo Starting GE Shopfloor MCE setup...
|
|
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
|
|
for /l %%i in (1,1,2000000) do rem
|
|
net use Z: \\172.16.9.1\winpeapps\ge-shopfloor-mce /user:pxe-upload pxe /persistent:no
|
|
goto end
|
|
|
|
:end
|
|
echo.
|
|
|
|
REM --- Push initial "WinPE staging" status to PXE webapp ---
|
|
REM Externalized to Y:\scripts\winpe-status-push.ps1 so future edits don't
|
|
REM require a boot.wim rebuild. Best-effort; the script logs to
|
|
REM X:\Windows\Temp\winpe-status-push.log and swallows all errors.
|
|
if exist "Y:\scripts\winpe-status-push.ps1" (
|
|
powershell -NoProfile -ExecutionPolicy Bypass -File "Y:\scripts\winpe-status-push.ps1"
|
|
)
|
|
|
|
echo Waiting for PESetup.exe to start...
|
|
:wait_start
|
|
ping -n 3 127.0.0.1 >NUL
|
|
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
|
|
if errorlevel 1 goto wait_start
|
|
echo PESetup.exe is running. Waiting for imaging to complete...
|
|
|
|
REM --- Copy enrollment package and shopfloor setup as soon as Windows partition appears ---
|
|
if "%PPKG%"=="" if "%PCTYPE%"=="" goto wait_finish
|
|
echo Waiting for Windows partition at W: ...
|
|
:wait_enroll
|
|
ping -n 11 127.0.0.1 >NUL
|
|
if not exist W:\Windows\System32\config\system goto wait_enroll
|
|
echo Found Windows at W:
|
|
mkdir W:\Enrollment 2>NUL
|
|
|
|
REM --- Copy site config (drives site-specific values in all setup scripts) ---
|
|
if exist "Y:\config\site-config.json" (
|
|
copy /Y "Y:\config\site-config.json" "W:\Enrollment\site-config.json"
|
|
echo Copied site-config.json.
|
|
) else (
|
|
echo WARNING: site-config.json not found on enrollment share.
|
|
)
|
|
|
|
REM --- Copy PPKG if selected (renames from SOURCE to BPRT-tagged filename) ---
|
|
if "%PPKG%"=="" goto copy_pctype
|
|
copy /Y "Y:\ppkgs\%SOURCE_PPKG%" "W:\Enrollment\%PPKG%"
|
|
if errorlevel 1 (
|
|
echo WARNING: Failed to copy enrollment package.
|
|
goto copy_pctype
|
|
)
|
|
copy /Y "Y:\scripts\run-enrollment.ps1" "W:\Enrollment\run-enrollment.ps1"
|
|
copy /Y "Y:\scripts\wait-for-internet.ps1" "W:\Enrollment\wait-for-internet.ps1"
|
|
copy /Y "Y:\scripts\migrate-to-wifi.ps1" "W:\Enrollment\migrate-to-wifi.ps1"
|
|
|
|
REM --- Create enroll.cmd at drive root as manual fallback ---
|
|
> W:\enroll.cmd (
|
|
echo @echo off
|
|
echo echo Waiting for network...
|
|
echo :waitnet
|
|
echo ping -n 2 8.8.8.8 ^>NUL 2^>^&1
|
|
echo if errorlevel 1 goto waitnet
|
|
echo echo Network connected. Running enrollment...
|
|
echo powershell.exe -ExecutionPolicy Bypass -File "C:\run-enrollment.ps1"
|
|
)
|
|
echo Manual fallback created at W:\enroll.cmd
|
|
|
|
:copy_pctype
|
|
REM --- Copy shopfloor PC type setup scripts ---
|
|
if "%PCTYPE%"=="" goto cleanup_enroll
|
|
echo %PCTYPE%> W:\Enrollment\pc-type.txt
|
|
REM 2026-05-04 rename reorg: pc-subtype.txt no longer written.
|
|
REM display-type.txt IS still written for gea-shopfloor-display because
|
|
REM Install-KioskApp.cmd reads it to pick Lobby vs Dashboard installer
|
|
REM and Get-PCProfile.ps1 reads it to build the Display-{type} profile key.
|
|
if not "%DISPLAYTYPE%"=="" echo %DISPLAYTYPE%> W:\Enrollment\display-type.txt
|
|
if not "%MACHINENUM%"=="" echo %MACHINENUM%> W:\Enrollment\machine-number.txt
|
|
REM Keyence model goes to BOTH keyence-model.txt (read by 09-Setup-Keyence) AND
|
|
REM pc-subtype.txt (read by GE-Enforce for per-model dispatch via existing
|
|
REM PCSubType wiring: looks for gea-shopfloor-keyence-<model>\manifest.json on share).
|
|
if not "%KEYENCEMODEL%"=="" (
|
|
echo %KEYENCEMODEL%> W:\Enrollment\keyence-model.txt
|
|
echo %KEYENCEMODEL%> W:\Enrollment\pc-subtype.txt
|
|
)
|
|
copy /Y "Y:\shopfloor-setup\Run-ShopfloorSetup.ps1" "W:\Enrollment\Run-ShopfloorSetup.ps1"
|
|
REM --- Always copy Shopfloor baseline scripts ---
|
|
mkdir W:\Enrollment\shopfloor-setup 2>NUL
|
|
copy /Y "Y:\shopfloor-setup\backup_lockdown.bat" "W:\Enrollment\shopfloor-setup\backup_lockdown.bat"
|
|
if exist "Y:\shopfloor-setup\Shopfloor" (
|
|
mkdir W:\Enrollment\shopfloor-setup\Shopfloor 2>NUL
|
|
xcopy /E /Y /I "Y:\shopfloor-setup\Shopfloor" "W:\Enrollment\shopfloor-setup\Shopfloor\"
|
|
echo Copied Shopfloor baseline setup files.
|
|
)
|
|
REM --- Always copy common/ (cross-PC-type GE-Enforce dispatcher + lib live here post-v2) ---
|
|
if exist "Y:\shopfloor-setup\common" (
|
|
mkdir W:\Enrollment\shopfloor-setup\common 2>NUL
|
|
xcopy /E /Y /I "Y:\shopfloor-setup\common" "W:\Enrollment\shopfloor-setup\common\"
|
|
echo Copied common setup files.
|
|
)
|
|
REM --- Copy _ntlars-backups (147 per-bay .reg files restored by gea-shopfloor-{collections,nocollections}\03-RestoreEDncConfig.ps1) ---
|
|
REM Same root level as common/, referenced by 03-RestoreEDncConfig.ps1 via Join-Path $PSScriptRoot '..\_ntlars-backups'.
|
|
if exist "Y:\shopfloor-setup\_ntlars-backups" (
|
|
mkdir W:\Enrollment\shopfloor-setup\_ntlars-backups 2>NUL
|
|
xcopy /E /Y /I "Y:\shopfloor-setup\_ntlars-backups" "W:\Enrollment\shopfloor-setup\_ntlars-backups\"
|
|
echo Copied _ntlars-backups.
|
|
)
|
|
REM --- Copy type-specific scripts on top of baseline ---
|
|
if exist "Y:\shopfloor-setup\%PCTYPE%" (
|
|
mkdir "W:\Enrollment\shopfloor-setup\%PCTYPE%" 2>NUL
|
|
xcopy /E /Y /I "Y:\shopfloor-setup\%PCTYPE%" "W:\Enrollment\shopfloor-setup\%PCTYPE%\"
|
|
echo Copied %PCTYPE% setup files.
|
|
) else (
|
|
echo WARNING: No setup files found for PC type %PCTYPE%.
|
|
)
|
|
|
|
REM --- Stage preinstall bundle (apps installed locally to save Azure bandwidth) ---
|
|
if exist "Y:\pre-install\preinstall.json" (
|
|
mkdir W:\PreInstall 2>NUL
|
|
mkdir W:\PreInstall\installers 2>NUL
|
|
copy /Y "Y:\pre-install\preinstall.json" "W:\PreInstall\preinstall.json"
|
|
if exist "Y:\pre-install\installers" (
|
|
xcopy /E /Y /I "Y:\pre-install\installers" "W:\PreInstall\installers\"
|
|
echo Staged preinstall bundle to W:\PreInstall.
|
|
) else (
|
|
echo WARNING: Y:\pre-install\installers not found - preinstall.json staged without installers.
|
|
)
|
|
if exist "Y:\pre-install\udc-backups" (
|
|
xcopy /E /Y /I "Y:\pre-install\udc-backups" "W:\PreInstall\udc-backups\"
|
|
echo Staged UDC settings backups to W:\PreInstall\udc-backups.
|
|
)
|
|
) else (
|
|
echo No preinstall bundle on PXE server - skipping.
|
|
)
|
|
|
|
REM --- Stage CMM bootstrap bundle (CMM-type PCs only) ---
|
|
REM Copies the Hexagon installer bundle (~1.9 GB) from the PXE server enrollment
|
|
REM share onto the target disk so 09-Setup-CMM.ps1 can install from local disk.
|
|
REM The tsgwp00525 SFLD share that holds the canonical copy is not yet reachable
|
|
REM during shopfloor-setup (Azure DSC provisions those creds later), so this
|
|
REM bootstrap exists to get the first-install through. Post-imaging, the
|
|
REM unified GE-Enforce dispatcher takes over from the share for ongoing updates.
|
|
if /i not "%PCTYPE%"=="gea-shopfloor-cmm" goto skip_cmm_stage
|
|
if exist "Y:\installers-post\cmm\cmm-manifest.json" (
|
|
mkdir W:\CMM-Install 2>NUL
|
|
xcopy /E /Y /I "Y:\installers-post\cmm" "W:\CMM-Install\"
|
|
echo Staged CMM bootstrap to W:\CMM-Install.
|
|
) else (
|
|
echo WARNING: Y:\cmm-installers not found - CMM PC cannot install Hexagon apps at imaging time.
|
|
)
|
|
:skip_cmm_stage
|
|
|
|
REM --- Stage Keyence per-model bootstrap bundle (Keyence PCs only) ---
|
|
REM Copies only the selected model's MSI + Data cabs from the PXE enrollment
|
|
REM share to the target disk. installers-post/keyence/<model>/ contains:
|
|
REM manifest.json
|
|
REM installers/{MSI, Data1.cab, [Data11.cab for vr3000], 1033.mst}
|
|
REM drivers/ (vr6000 only - older external .inf; vr3000/vr5000 drivers
|
|
REM are embedded in their MSIs)
|
|
REM 09-Setup-Keyence.ps1 reads C:\Enrollment\keyence-model.txt to know which.
|
|
if /i not "%PCTYPE%"=="gea-shopfloor-keyence" goto skip_keyence_stage
|
|
if "%KEYENCEMODEL%"=="" goto skip_keyence_stage
|
|
if exist "Y:\installers-post\keyence\%KEYENCEMODEL%\manifest.json" (
|
|
mkdir W:\KeyenceInstall 2>NUL
|
|
mkdir W:\KeyenceInstall\%KEYENCEMODEL% 2>NUL
|
|
xcopy /E /Y /I "Y:\installers-post\keyence\%KEYENCEMODEL%" "W:\KeyenceInstall\%KEYENCEMODEL%\"
|
|
echo Staged Keyence %KEYENCEMODEL% bootstrap to W:\KeyenceInstall\%KEYENCEMODEL%\.
|
|
) else (
|
|
echo WARNING: Y:\installers-post\keyence\%KEYENCEMODEL% not found - Keyence %KEYENCEMODEL% cannot install at imaging time.
|
|
)
|
|
:skip_keyence_stage
|
|
|
|
REM --- Stage WaxTrace bootstrap bundle (wax/trace gea-shopfloor-waxtrace only) ---
|
|
REM Copies the FormTracePak master capture (~110 MB compressed) + HASP +
|
|
REM VC++ redists + per-machine cal ISOs from the enrollment share onto the
|
|
REM target disk so 09-Setup-WaxAndTrace.ps1 can install FormTracePak via
|
|
REM xcopy + reg-import (bypassing Mitutoyo's CD-ROM-bound VB6 wrapper).
|
|
if /i not "%PCTYPE%"=="gea-shopfloor-waxtrace" goto skip_waxtrace_stage
|
|
if exist "Y:\installers-post\waxtrace\waxtrace-manifest.json" (
|
|
mkdir W:\WaxTrace-Install 2>NUL
|
|
xcopy /E /Y /I "Y:\installers-post\waxtrace" "W:\WaxTrace-Install\"
|
|
echo Staged WaxTrace bootstrap to W:\WaxTrace-Install.
|
|
) else (
|
|
echo WARNING: Y:\installers-post\waxtrace not found - WaxTrace PC cannot install FormTracePak at imaging time.
|
|
)
|
|
:skip_waxtrace_stage
|
|
:pctype_done
|
|
|
|
REM --- BIOS update sub-stage push (fires AFTER W: copies complete) ---
|
|
REM check-bios.cmd drops X:\bios-fired.flag iff it actually flashed or
|
|
REM staged a firmware update. Reading the flag file is more reliable than
|
|
REM scanning BIOS_STATUS for substrings (caret escaping inside quoted SET
|
|
REM is subtle in WinPE cmd.exe). Push must happen before Y: cleanup since
|
|
REM the push script lives on the share.
|
|
if exist X:\bios-fired.flag (
|
|
if exist "Y:\scripts\winpe-status-push.ps1" (
|
|
powershell -NoProfile -ExecutionPolicy Bypass -File "Y:\scripts\winpe-status-push.ps1" -CurrentStage "WinPE: BIOS firmware update"
|
|
)
|
|
)
|
|
|
|
:cleanup_enroll
|
|
net use Y: /delete 2>NUL
|
|
|
|
:wait_finish
|
|
ping -n 11 127.0.0.1 >NUL
|
|
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
|
|
if not errorlevel 1 goto wait_finish
|
|
echo.
|
|
echo Imaging complete. Rebooting in 15 seconds...
|
|
echo Press Ctrl+C to cancel.
|
|
ping -n 16 127.0.0.1 >NUL
|
|
wpeutil reboot
|