Files
pxe-server/scripts/e10-client.py
cproudlock 5e249e8ad0 feat(e10): run on Windows as well as Linux
Serial access moves behind open_port(), with a termios backend on POSIX and a
Win32 backend reached through ctypes. Deliberately no pyserial: these tools
have to run on locked-down, air-gapped shopfloor machines where installing a
package is a project of its own.

Verified on a real controller from both a Linux laptop and a Windows 11 PC.

Three things that made this harder than it should have been, all now handled:

  - CreateFileW returns a HANDLE, which is 64-bit. Without an explicit restype
    ctypes truncates it to c_int. The open then appears to succeed and every
    read and write silently operates on a bogus handle, which looks exactly
    like a dead cable. Every kernel32 call now declares argtypes and restype.

  - Defaulting to a fixed COM number was actively harmful. A wrong-but-real
    port opens without error and answers nothing, so defaulting to COM3 while
    the adapter was on COM4 produced the same silent symptom. Windows now
    auto-picks only when exactly one port looks like a USB virtual COM port,
    and otherwise refuses and lists what it found.

  - COM10 and above need the \\.\ prefix, which is harmless on COM1-9, so it
    is always applied.

Adds two diagnostics, because "no response" has too many possible causes to
guess at:
  ports    every serial port that actually exists. On Windows this reads
           SERIALCOMM from the registry, so a port absent here does not exist
           now, whatever Device Manager showed last week.
  doctor   walks the layers - discovery, open, write, read - and reports which
           one fails, including a warning when the configured port is an
           onboard one while a USB adapter is present.

Port selection is -d, then $E10_PORT, then the safe auto-pick. Friendlier
errors on both platforms for a missing port or a permissions problem.
2026-08-27 13:40:15 -04:00