Field bay surfaced two bugs in one diag dump (mdm-diag-F907T5X3 - 6PPSF24): 1. GE Proactive Remediation Report IP actually writes GE_Report_IP_Address_2_5.LOG (uppercase .LOG), not the .txt I assumed. Globs in two places had .txt filter -> never matched -> Phase 1 stuck IN PROGRESS forever even after the file landed and wired-NIC re-enable never fired. Drop extension from both globs in Monitor-IntuneProgress.ps1 (id=7 push gate + p1Done check). 2. The "GE Re-enable Wired NICs" SYSTEM task registered by Run-ShopfloorSetup was polling Autologon_Remediation.log for "Autologon set for ShopFloor" - a lockdown-time signal. Re-enable needs to fire at Report-IP time (well before lockdown) so that Monitor can push idx=7 with the QR before the Intune-triggered LAPS-prompt reboot. Repoint the SYSTEM task's poll to C:\Logs\GE_Report_IP_Address* (any extension). Plus minor UX: copy button next to the Intune device ID on /imaging dashboard so techs can grab the GUID without having to double-click-select the <code>. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>