Files
pxe-server/playbook/preinstall/preinstall.json
cproudlock 9235d19e55 preinstall: drop Oracle 10.2.0.3, defer to runtime enforcer for 11.2
10.2.0.3 was being installed into every Standard/CMM/Genspect/Keyence/
WaxAndTrace/Display image at build time. Oracle 11.2 is now installed
and version-enforced at runtime by the GE-Enforce common manifest
entry (Install-Oracle11r2.cmd), so baking 10.2 into the image creates
drift: 10.2 on disk, 11.2 expected by registry. Remove from preinstall.json
and drop the flat installer from sync-preinstall.sh so new builds come
up clean and the enforcer does the install on first boot.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-22 16:15:01 -04:00

188 lines
12 KiB
JSON

{
"Version": "1.0",
"Site": "West Jefferson",
"Applications": [
{
"_comment": "VC++ 2008 SP1 x86 - the bootstrapper (vcredist2008_x86.exe) ignores /norestart and triggers an immediate Windows reboot when files are in use (per Aaron Stebner's MSDN docs). Fix: install the extracted vc_red.msi directly with REBOOT=ReallySuppress, which IS hard-honored by Windows Installer. msiexec may return 3010 (would-have-rebooted-but-suppressed) but won't actually reboot. cab name 'vc_red.cab' is hardcoded in the MSI's Media table - do not rename.",
"Name": "VC++ Redistributable 2008 x86",
"Installer": "vcredist/2008/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{9BE518E6-ECC6-35A9-88E4-87755C07200F}",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2010 x86 - same fix as 2008. Bootstrapper ignores /norestart; extracted MSI with REBOOT=ReallySuppress does not.",
"Name": "VC++ Redistributable 2010 x86",
"Installer": "vcredist/2010/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2012 x86 Minimum Runtime - extracted from vcredist2012_x86.exe Burn bundle. Same REBOOT=ReallySuppress fix.",
"Name": "VC++ Redistributable 2012 x86 (Minimum)",
"Installer": "vcredist/2012-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}",
"PCTypes": ["*"]
},
{
"Name": "VC++ Redistributable 2012 x86 (Additional)",
"Installer": "vcredist/2012-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{B175520C-86A2-35A7-8619-86DC379688B9}",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2013 x86 Minimum Runtime - extracted from vcredist2013_x86.exe Burn bundle.",
"Name": "VC++ Redistributable 2013 x86 (Minimum)",
"Installer": "vcredist/2013-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{13A4EE12-23EA-3371-91EE-EFB36DDFFF3E}",
"PCTypes": ["*"]
},
{
"Name": "VC++ Redistributable 2013 x86 (Additional)",
"Installer": "vcredist/2013-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F8CFEB22-A2E7-3971-9EDA-4B11EDEFC185}",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2013 x64 Minimum Runtime - required by Keyence VR-6000 Series Software. Extracted from the Keyence installer's Windows Installer cache. Same REBOOT=ReallySuppress pattern as the x86 variants.",
"Name": "VC++ Redistributable 2013 x64 (Minimum)",
"Installer": "vcredist/2013-x64-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{A749D8E6-B613-3BE3-8F5F-045C84EBA29B}",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2013 x64 Additional Runtime - required by Keyence VR-6000 Series Software. Pairs with the Minimum Runtime above.",
"Name": "VC++ Redistributable 2013 x64 (Additional)",
"Installer": "vcredist/2013-x64-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{929FBD26-9020-399B-9A7A-751D61F0B942}",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2010 x64 - required by PC-DMIS 2016/2019 R2 on CMM PCs. PCDLRN.exe links against msvcr100.dll and the VS 2010 MFC DLLs which are only provided by this redistributable. Extracted from the PC-DMIS 2016 bundle's attached container (a1 payload). Silent install: /q /norestart. Detection: Uninstall key under the native x64 hive with fixed product GUID.",
"Name": "VC++ Redistributable 2010 x64",
"Installer": "vcredist/2010-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{1D8E6291-B0D5-35EC-8441-6616F567A0F7}",
"DetectionName": "DisplayVersion",
"DetectionValue": "10.0.40219",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2012 x64 - required by PC-DMIS 2016/2019 R2. Same rationale as 2010 x64; PC-DMIS links against msvcr110.dll / MFC110. Extracted from the PC-DMIS 2016 bundle's attached container (a2 payload). Detection on the Minimum Runtime GUID (the main redist wrapper installs both Minimum and Additional sub-packages).",
"Name": "VC++ Redistributable 2012 x64",
"Installer": "vcredist/2012-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{5AF4E09F-5C9B-3AAF-B731-544D3DC821DD}",
"DetectionName": "DisplayVersion",
"DetectionValue": "11.0.51106",
"PCTypes": ["*"]
},
{
"_comment": "VC++ 2015-2022 x86 - extracted from vcredist2015_2017_2019_2022_x86.exe Burn bundle. The bundle contains 2022 14.44.35211 plus 8 chained KB updates for older 2015/2017/2019 releases. We install only the 2022 Min+Add MSIs - the CRT v140 ABI is shared across 2015/2017/2019/2022, so the latest pair covers all four versions on Windows 10/11.",
"Name": "VC++ Redistributable 2022 x86 (Minimum)",
"Installer": "vcredist/2022-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{922480B5-CAEB-4B1B-AAA4-9716EFDCE26B}",
"PCTypes": ["*"]
},
{
"Name": "VC++ Redistributable 2022 x86 (Additional)",
"Installer": "vcredist/2022-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{C18FB403-1E88-43C8-AD8A-CED50F23DE8B}",
"PCTypes": ["*"]
},
{
"_comment": "Adobe Acrobat Reader DC - same version as GEA-Engineering image. Two-step install via Install-AcroReader.cmd wrapper: base MSI with enterprise transform (AcroRead.mst) then DC update patch (AcroRdrDCUpd2500120531.msp). Source files on PXE server at /srv/samba/winpeapps/gea-engineer/Deploy/Applications/extra/adobe/ - copy to /srv/samba/enrollment/preinstall/installers/adobe/.",
"Name": "Adobe Acrobat Reader DC",
"Installer": "adobe\\Install-AcroReader.cmd",
"Type": "EXE",
"InstallArgs": "",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\Adobe\\Acrobat Reader DC\\Reader\\AcroRd32.exe",
"PCTypes": ["*"]
},
{
"_comment": "OpenText HostExplorer 15 SP1 ShopFloor - replaced the WJDT-built OpenText.exe Inno wrapper with our own Setup-OpenText.ps1 that does the same install steps (msiexec base + ShopFloor.mst transform + SP1 .msp patch) PLUS fans the per-user profile/keymap/menu/macro content out to Default User and every existing user profile. The Inno wrapper deployed per-user content to {userappdata} which resolves to whichever user is running the installer (SYSTEM under DSC, single user under PreInstall) so Azure-AD users never saw the profiles. Setup-OpenText.cmd is a tiny launcher that hands off to Setup-OpenText.ps1 because the runner only handles MSI/EXE types. All bundled files live in vcredist-style subtree at dependencies/opentext/ and get xcopied through WinPE staging. NO DetectionMethod here on purpose - Setup-OpenText.ps1 owns its own version check by reading version.txt next to itself and comparing to HKLM:\\SOFTWARE\\GE\\OpenText\\Installed; the runner always invokes the wrapper (cost: ~1s of PowerShell launch when up-to-date) so the version constant lives in exactly one place: dependencies/opentext/version.txt.",
"Name": "OpenText HostExplorer ShopFloor",
"Installer": "opentext\\Setup-OpenText.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Setup-OpenText.log",
"PCTypes": ["Standard", "CMM", "Keyence", "Genspect", "WaxAndTrace", "Lab"]
},
{
"_comment": "UDC_Setup.exe spawns a hidden WPF window (UDC.exe) after install and never exits, so the runner needs KillAfterDetection: true to terminate UDC_Setup.exe + UDC.exe once the registry detection passes. This is an OPT-IN flag - normal installers should NOT set it because killing msiexec mid-install leaves msiserver holding the install mutex and the next msiexec call returns 1618 (Oracle hit this exact bug).",
"Name": "UDC",
"Installer": "UDC_Setup.exe",
"Type": "EXE",
"InstallArgs": "\"West Jefferson\" -9999",
"KillAfterDetection": true,
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\UDC",
"PCTypes": ["Standard-Machine"]
},
{
"_comment": "Display kiosk app (Lobby Display or Dashboard). Install-KioskApp.cmd wrapper reads C:\\Enrollment\\display-type.txt to determine which installer to run. Both GEAerospaceLobbyDisplaySetup.exe and GEAerospaceDashboardSetup.exe must be staged in the display\\ subtree alongside the wrapper. Inno Setup /VERYSILENT is idempotent so no detection needed.",
"Name": "Display Kiosk App",
"Installer": "display\\Install-KioskApp.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Dashboard-install.log",
"PCTypes": ["Display"]
},
{
"_comment": "WJF Defect Tracker - replaces old ClickOnce deployment. MSI creates desktop + Start Menu shortcuts. Enforcer on SFLD share handles version updates post-imaging. TARGETDIR explicit because VS deployment MSI defaults to random path without it.",
"Name": "WJF Defect Tracker",
"Installer": "WJF_Defect_Tracker.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ALLUSERS=1 REBOOT=ReallySuppress TARGETDIR=\"C:\\Program Files (x86)\\WJF_Defect_Tracker\"",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\WJF_Defect_Tracker\\Defect_Tracker.exe",
"PCTypes": ["*"]
},
{
"_comment": "Shopfloor Standard serial-port drivers: StarTech PCIe serial adapter (MosChip-based) + Prolific PL2303 USB-to-serial. Install-Drivers.cmd runs pnputil /add-driver with /subdirs /install so every bundled INF under drivers/ lands in the Windows driver store and auto-binds to matching hardware present now or plugged in later. Scoped to Standard PCs (both Machine + Timeclock) because the PCTypes filter is type-level only; installing a serial driver on a Timeclock without the hardware is harmless - it just sits in the driver store.",
"Name": "Shopfloor Serial Drivers",
"Installer": "drivers\\Install-Drivers.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Install-Drivers.log",
"DetectionMethod": "File",
"DetectionPath": "C:\\ProgramData\\PXEDrivers\\drivers-installed.marker",
"PCTypes": ["Standard"]
}
]
}