UDC_Setup.exe and UDC.exe expect: UDC_Setup.exe WestJefferson -7605 Not the spaced-quoted positional pair we'd been passing: UDC_Setup.exe "West Jefferson" 7605 The wrong format meant UDC ignored both args, fell back to defaults (Site=Evendale, MachineNumber=blank). Combined with the kill-after-detect window, neither value got persisted to udc_settings.json regardless of whether UDC.exe was given time to write. Changes: - preinstall.json: UDC InstallArgs now "WestJefferson -9999" - 00-PreInstall-MachineApps.ps1: site override now matches/replaces the compact 'WestJefferson' token (not 'West Jefferson') and uses siteNameCompact from site-config; targetNum extraction regex updated to '-(\d+)$' for the new dash-prefix format - Update-MachineNumber.ps1: UDC.exe relaunch now passes positional compact-site + dash-prefixed number instead of -site/-machine flags Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>