Files
pxe-server/startnet-template.cmd
cproudlock f3211dfd29 CMM test iteration: desktop shortcuts, rename to 09-Setup-*, defer NIC re-enable
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.

- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
  "09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
  and WaxAndTrace. The "01-" prefix implied the script runs first in
  the overall sequence when it actually runs between baseline (00, 04)
  and finalization (06, 07). Logs now read "Running CMM setup:
  09-Setup-CMM.ps1" which matches the real position. Standard/
  01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
  represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
  - startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
    which the user does not want on CMM workstations. Now relies on
    the Get-ProfileValue empty-array fix to not fall through to site
    defaults.
  - desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
    2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
    materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
    and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
    (x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
  "UNPLUG ethernet cable, press any key" prompt + the interactive
  wired-NIC re-enable. The whole prompt block was a hard blocker on
  the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
  re-enable wired NICs unconditionally at the top of the transcript.
  This is the new home for the re-enable that used to live behind the
  prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
  PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
  minutes of wall-clock time to physically rewire from PXE to
  production without us blocking on a keypress. Tower case is a
  no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
  Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
  to reflect the new filename.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 21:03:09 -04:00

354 lines
12 KiB
Batchfile

@echo off
echo Please wait while 'WinPE' is being processed. This may take a few seconds.
wpeinit
powercfg /s 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c
REM --- Wait for network (DHCP may take a moment after wpeinit) ---
echo Waiting for network...
:wait_net
ping -n 2 10.9.100.1 >NUL 2>&1
if errorlevel 1 goto wait_net
echo Network ready.
REM --- BIOS update check (runs before imaging menu) ---
set BIOS_STATUS=No BIOS check (share unavailable)
net use B: \\10.9.100.1\winpeapps\_shared /user:pxe-upload pxe /persistent:no 2>NUL
if exist B:\BIOS\check-bios.cmd (
echo.
echo Checking for BIOS updates...
call B:\BIOS\check-bios.cmd
REM If BIOS was flashed, check-bios.cmd reboots and we never reach here.
echo.
)
net use B: /delete 2>NUL
:menu
cls
echo.
echo ========================================
echo WinPE Setup Menu
echo ========================================
echo Firmware: %BIOS_STATUS%
echo.
echo Please select an option:
echo.
echo 1. GEA Standard
echo 2. GEA Engineer
echo 3. GEA Shopfloor
echo 4. GE Standard
echo 5. GE Engineer
echo 6. GE Shopfloor Lockdown
echo 7. GE Shopfloor MCE
echo.
echo ========================================
echo.
set /p choice=Enter your choice (1-7):
REM --- Only shopfloor images (3,6,7) need GCCH enrollment ---
set PPKG=
if "%choice%"=="3" goto enroll_menu
if "%choice%"=="6" goto enroll_menu
if "%choice%"=="7" goto enroll_menu
goto enroll_staged
:enroll_menu
cls
echo.
echo ========================================
echo GCCH Enrollment Profile
echo ========================================
echo.
echo 1. No Office
echo 2. Standard Office (x86)
echo 3. Standard Office (x64)
echo 4. Pro Plus Office (x86) with Access
echo 5. Pro Plus Office (x64) with Access
echo 6. Skip enrollment
echo.
set /p enroll=Enter your choice (1-6):
if "%enroll%"=="1" set PPKG=GCCH_Prod_SFLD_NoOffice_US_Exp_20260430_v4.8.ppkg
if "%enroll%"=="2" set PPKG=GCCH_Prod_SFLD_StdOffice-x86_US_Exp_20260430_v4.8.ppkg
if "%enroll%"=="3" set PPKG=GCCH_Prod_SFLD_StdOffice-x64_US_Exp_20260430_v4.8.ppkg
if "%enroll%"=="4" set PPKG=GCCH_Prod_SFLD_ProPlusOffice-x86_US_Exp_20260430_v4.8.ppkg
if "%enroll%"=="5" set PPKG=GCCH_Prod_SFLD_ProPlusOffice-x64_US_Exp_20260430_v4.8.ppkg
if "%enroll%"=="6" set PPKG=
if "%enroll%"=="" goto enroll_menu
:pctype_menu
cls
echo.
echo ========================================
echo Shopfloor PC Type
echo ========================================
echo.
echo 1. CMM
echo 2. Wax and Trace
echo 3. Keyence
echo 4. Genspect
echo 5. Display
echo 6. Standard
echo 7. Lab
echo.
set PCTYPE=
set /p pctype_choice=Enter your choice (1-7):
if "%pctype_choice%"=="1" set PCTYPE=CMM
if "%pctype_choice%"=="2" set PCTYPE=WaxAndTrace
if "%pctype_choice%"=="3" set PCTYPE=Keyence
if "%pctype_choice%"=="4" set PCTYPE=Genspect
if "%pctype_choice%"=="5" set PCTYPE=Display
if "%pctype_choice%"=="6" set PCTYPE=Standard
if "%pctype_choice%"=="7" set PCTYPE=Lab
if "%PCTYPE%"=="" goto pctype_menu
REM --- Sub-type selection menus ---
REM PCSUBTYPE is written to pc-subtype.txt alongside pc-type.txt.
REM Scripts read it to look up the right profile in site-config.json.
set PCSUBTYPE=
set DISPLAYTYPE=
REM --- Standard sub-type ---
if not "%PCTYPE%"=="Standard" goto skip_standard_menu
:standard_menu
cls
echo.
echo ========================================
echo Standard PC Sub-Type
echo ========================================
echo.
echo 1. Timeclock (WJ Shopfloor only)
echo 2. Machine (WJ Shopfloor, Plant Apps, eDNC, UDC)
echo.
set /p standard_choice=Enter your choice (1-2):
if "%standard_choice%"=="1" set PCSUBTYPE=Timeclock
if "%standard_choice%"=="2" set PCSUBTYPE=Machine
if "%PCSUBTYPE%"=="" goto standard_menu
REM --- Machine number (Standard only) ---
set MACHINENUM=9999
echo.
set /p MACHINENUM=Enter machine number (digits, or Enter for 9999):
if "%MACHINENUM%"=="" set MACHINENUM=9999
echo Machine number: %MACHINENUM%
:skip_standard_menu
REM --- Display sub-type ---
if not "%PCTYPE%"=="Display" goto skip_display_menu
:display_menu
cls
echo.
echo ========================================
echo Display Type
echo ========================================
echo.
echo 1. Lobby Display
echo 2. Dashboard
echo.
set /p display_choice=Enter your choice (1-2):
if "%display_choice%"=="1" set DISPLAYTYPE=Lobby
if "%display_choice%"=="1" set PCSUBTYPE=Lobby
if "%display_choice%"=="2" set DISPLAYTYPE=Dashboard
if "%display_choice%"=="2" set PCSUBTYPE=Dashboard
if "%PCSUBTYPE%"=="" goto display_menu
:skip_display_menu
REM --- Map enrollment share early (kept open for copy after imaging) ---
set NEED_ENROLL=0
if not "%PPKG%"=="" set NEED_ENROLL=1
if not "%PCTYPE%"=="" set NEED_ENROLL=1
if "%NEED_ENROLL%"=="0" goto enroll_staged
net use Y: \\10.9.100.1\enrollment /user:pxe-upload pxe /persistent:no
if "%PPKG%"=="" goto enroll_staged
if not exist "Y:\%PPKG%" (
echo WARNING: %PPKG% not found on server. Enrollment will be skipped.
set PPKG=
)
:enroll_staged
echo. > X:\Boot.tag
if "%choice%"=="1" goto gea-standard
if "%choice%"=="2" goto gea-engineer
if "%choice%"=="3" goto gea-shopfloor
if "%choice%"=="4" goto ge-standard
if "%choice%"=="5" goto ge-engineer
if "%choice%"=="6" goto ge-shopfloor-lockdown
if "%choice%"=="7" goto ge-shopfloor-mce
echo Invalid choice. Please try again.
pause
goto menu
:gea-standard
echo.
echo Starting GEA Standard setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\gea-standard /user:pxe-upload pxe /persistent:no
goto end
:gea-engineer
echo.
echo Starting GEA Engineer setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\gea-engineer /user:pxe-upload pxe /persistent:no
goto end
:gea-shopfloor
echo.
echo Starting GEA Shopfloor setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\gea-shopfloor /user:pxe-upload pxe /persistent:no
goto end
:ge-standard
echo.
echo Starting GE Standard setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\ge-standard /user:pxe-upload pxe /persistent:no
goto end
:ge-engineer
echo.
echo Starting GE Engineer setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\ge-engineer /user:pxe-upload pxe /persistent:no
goto end
:ge-shopfloor-lockdown
echo.
echo Starting GE Shopfloor Lockdown setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\ge-shopfloor-lockdown /user:pxe-upload pxe /persistent:no
goto end
:ge-shopfloor-mce
echo.
echo Starting GE Shopfloor MCE setup...
start "FlatApp" %SYSTEMDRIVE%\GESetup\FlatSetupLoader.exe
for /l %%i in (1,1,2000000) do rem
net use Z: \\10.9.100.1\winpeapps\ge-shopfloor-mce /user:pxe-upload pxe /persistent:no
goto end
:end
echo.
echo Waiting for PESetup.exe to start...
:wait_start
ping -n 3 127.0.0.1 >NUL
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
if errorlevel 1 goto wait_start
echo PESetup.exe is running. Waiting for imaging to complete...
REM --- Copy enrollment package and shopfloor setup as soon as Windows partition appears ---
if "%PPKG%"=="" if "%PCTYPE%"=="" goto wait_finish
echo Waiting for Windows partition at W: ...
:wait_enroll
ping -n 11 127.0.0.1 >NUL
if not exist W:\Windows\System32\config\system goto wait_enroll
echo Found Windows at W:
mkdir W:\Enrollment 2>NUL
REM --- Copy site config (drives site-specific values in all setup scripts) ---
if exist "Y:\site-config.json" (
copy /Y "Y:\site-config.json" "W:\Enrollment\site-config.json"
echo Copied site-config.json.
) else (
echo WARNING: site-config.json not found on enrollment share.
)
REM --- Copy PPKG if selected ---
if "%PPKG%"=="" goto copy_pctype
copy /Y "Y:\%PPKG%" "W:\Enrollment\%PPKG%"
if errorlevel 1 (
echo WARNING: Failed to copy enrollment package.
goto copy_pctype
)
copy /Y "Y:\run-enrollment.ps1" "W:\Enrollment\run-enrollment.ps1"
copy /Y "Y:\wait-for-internet.ps1" "W:\Enrollment\wait-for-internet.ps1"
copy /Y "Y:\migrate-to-wifi.ps1" "W:\Enrollment\migrate-to-wifi.ps1"
REM --- Create enroll.cmd at drive root as manual fallback ---
> W:\enroll.cmd (
echo @echo off
echo echo Waiting for network...
echo :waitnet
echo ping -n 2 8.8.8.8 ^>NUL 2^>^&1
echo if errorlevel 1 goto waitnet
echo echo Network connected. Running enrollment...
echo powershell.exe -ExecutionPolicy Bypass -File "C:\run-enrollment.ps1"
)
echo Manual fallback created at W:\enroll.cmd
:copy_pctype
REM --- Copy shopfloor PC type setup scripts ---
if "%PCTYPE%"=="" goto cleanup_enroll
echo %PCTYPE%> W:\Enrollment\pc-type.txt
if not "%DISPLAYTYPE%"=="" echo %DISPLAYTYPE%> W:\Enrollment\display-type.txt
if not "%PCSUBTYPE%"=="" echo %PCSUBTYPE%> W:\Enrollment\pc-subtype.txt
if not "%MACHINENUM%"=="" echo %MACHINENUM%> W:\Enrollment\machine-number.txt
copy /Y "Y:\shopfloor-setup\Run-ShopfloorSetup.ps1" "W:\Enrollment\Run-ShopfloorSetup.ps1"
REM --- Always copy Shopfloor baseline scripts ---
mkdir W:\Enrollment\shopfloor-setup 2>NUL
copy /Y "Y:\shopfloor-setup\backup_lockdown.bat" "W:\Enrollment\shopfloor-setup\backup_lockdown.bat"
if exist "Y:\shopfloor-setup\Shopfloor" (
mkdir W:\Enrollment\shopfloor-setup\Shopfloor 2>NUL
xcopy /E /Y /I "Y:\shopfloor-setup\Shopfloor" "W:\Enrollment\shopfloor-setup\Shopfloor\"
echo Copied Shopfloor baseline setup files.
)
REM --- Copy type-specific scripts on top of baseline ---
if exist "Y:\shopfloor-setup\%PCTYPE%" (
mkdir "W:\Enrollment\shopfloor-setup\%PCTYPE%" 2>NUL
xcopy /E /Y /I "Y:\shopfloor-setup\%PCTYPE%" "W:\Enrollment\shopfloor-setup\%PCTYPE%\"
echo Copied %PCTYPE% setup files.
) else (
echo WARNING: No setup files found for PC type %PCTYPE%.
)
REM --- Stage preinstall bundle (apps installed locally to save Azure bandwidth) ---
if exist "Y:\preinstall\preinstall.json" (
mkdir W:\PreInstall 2>NUL
mkdir W:\PreInstall\installers 2>NUL
copy /Y "Y:\preinstall\preinstall.json" "W:\PreInstall\preinstall.json"
if exist "Y:\preinstall\installers" (
xcopy /E /Y /I "Y:\preinstall\installers" "W:\PreInstall\installers\"
echo Staged preinstall bundle to W:\PreInstall.
) else (
echo WARNING: Y:\preinstall\installers not found - preinstall.json staged without installers.
)
) else (
echo No preinstall bundle on PXE server - skipping.
)
REM --- Stage CMM bootstrap bundle (CMM-type PCs only) ---
REM Copies the Hexagon installer bundle (~1.9 GB) from the PXE server enrollment
REM share onto the target disk so 09-Setup-CMM.ps1 can install from local disk.
REM The tsgwp00525 SFLD share that holds the canonical copy is not yet reachable
REM during shopfloor-setup (Azure DSC provisions those creds later), so this
REM bootstrap exists to get the first-install through. Post-imaging, the logon-
REM triggered CMM-Enforce.ps1 takes over from the share.
if /i not "%PCTYPE%"=="CMM" goto skip_cmm_stage
if exist "Y:\cmm-installers\cmm-manifest.json" (
mkdir W:\CMM-Install 2>NUL
xcopy /E /Y /I "Y:\cmm-installers" "W:\CMM-Install\"
echo Staged CMM bootstrap to W:\CMM-Install.
) else (
echo WARNING: Y:\cmm-installers not found - CMM PC cannot install Hexagon apps at imaging time.
)
:skip_cmm_stage
:pctype_done
:cleanup_enroll
net use Y: /delete 2>NUL
:wait_finish
ping -n 11 127.0.0.1 >NUL
wmic process where "name='PESetup.exe'" get name 2>NUL | find /I "PESetup" >NUL
if not errorlevel 1 goto wait_finish
echo.
echo Imaging complete. Rebooting in 15 seconds...
echo Press Ctrl+C to cancel.
ping -n 16 127.0.0.1 >NUL
wpeutil reboot