Both kiosks admit a check-in or check-out with no login when the caller sits in a configured network. The subtraction that makes that safe was missing. A reverse proxy normally sits ON the plant network a site enters in the allowlist. When the proxy forwards nothing - misconfigured, or something bypassed it - the request arrives wearing the proxy's own address, which matches the allowlist, while carrying no evidence whatever about who sent it. That is the one case that has to refuse, and it was being admitted. The previous fail-closed test only looked closed because the proxy in it happened to sit outside the range. Addresses that belong to the path are now subtracted before the allowlist is consulted: loopback always, since no site's kiosk is the server itself, plus whatever the site declares as its proxies. USB and printedparts get the same treatment - they had diverged for no reason anybody chose. Three more, same surface: A range that admits everybody can no longer be saved by accident. 0.0.0.0/0 and ::/0 are refused outright, anything wider than a site plausibly needs is refused unless an explicit override is set, and the refusal says why. The kiosk token no longer travels in a URL. The provisioning link carries a single-use setup code redeemed on first open, so the token stays out of browser history, referrers and proxy logs. The route is declared public deliberately: the secret is the code, the way a password-reset link is the secret. The badge-to-name lookup is bounded. It answers without a login and is now reachable from a whole network rather than one screen, so a source that keeps missing gets refused rather than being allowed to walk the directory. On by default, budget and kill switch are settings. All four new settings carry controls on their settings pages. A setting that can stop the kiosk, or widen it, must not be reachable only by hand-editing rows. The installer's client-IP advice is corrected: it described the opposite of what the shipped waitress flags do, and named only GE-Enforce as the thing that breaks when the rule is absent, when the two kiosk allowlists depend on it too.
USB plugin - CMMC USB check-in/out database contract
The USB plugin tracks removable-media check-in/out for CMMC compliance. Device
and log state live in a separate, read-write MySQL database (cmmc_usb),
reached with parameterized pymysql via cmmc_usb_connection(). Names of people
are resolved from the HR employee directory (see the employees plugin).
The plugin's own reference tables (usbdevicetypes, usbdevices,
usbcheckouts) live in the main app database; only the live check-in/out data
is in cmmc_usb.
The schema is standardized across sites - the
cmmc_usbcheck-in/out solution is the same deployment everywhere, so the tables below match as-is and no schema adaptation is needed. The database name may differ per site, though - setcmmc_usb_db_name(defaultcmmc_usb) to match the local name. The view recipe at the end is only a fallback for a site that somehow differs. (Contrast the employee directory, which genuinely varies per site.)
Connection
Credentials resolve settings-first, then environment, except the password which is env-only (never stored in the app database).
| Field | Setting key (editable in the setup wizard) | Env var (fallback) |
|---|---|---|
| Host | cmmc_usb_db_host |
CMMC_USB_DB_HOST |
| Database | cmmc_usb_db_name |
CMMC_USB_DB_NAME |
| User | cmmc_usb_db_user |
CMMC_USB_DB_USER |
| Password | (not stored) | CMMC_USB_DB_PASSWORD |
Set the password in .env; the setup wizard's Features step shows the exact
line to paste. This database is read-write - the app account needs
SELECT, INSERT, UPDATE. Engine is MySQL/MariaDB (pymysql).
Required schema
The plugin runs raw SQL against these tables (or views - see below).
devices
| Column | Type | Notes |
|---|---|---|
device_id |
VARCHAR | Primary key; the device serial/tag |
device_desc |
VARCHAR | Description |
device_owner |
VARCHAR | Owner |
status |
VARCHAR | Check-in/out state |
locker_location |
VARCHAR | Where the device is stored |
Operations: SELECT (list + by id), INSERT (register device), UPDATE
(edit fields, change status).
checkinoutlog
| Column | Type | Notes |
|---|---|---|
log_id |
INT (PK) | Auto id |
badge_number |
VARCHAR | Person's badge |
device_id |
VARCHAR | FK to devices.device_id |
action |
VARCHAR | check-in / check-out |
timestamp |
DATETIME | When it happened |
scanned_viruses |
(text/int) | Scan result |
locker_location |
VARCHAR | Locker at time of event |
sanitized |
(bool/int) | Sanitization flag |
Operations: SELECT (history per device), INSERT (log an event).
users
| Column | Type | Notes |
|---|---|---|
badge_number |
VARCHAR | Primary key; the scanned badge |
first_name |
VARCHAR | Given name |
last_name |
VARCHAR | Surname |
Operations: SELECT by badge, INSERT (auto-add a badge on first scan).
Employee directory dependency
To turn a scanned badge into a name, the plugin also reads the HR employees
directory (via the employees plugin's connection). A badge shaped 0<digits>BZ
carries a PayNo (the digits); lookups try employees.SSO and employees.PayNo.
See plugins/employees/README.md for that schema and connection.
Adapting a different site schema (recommended: views)
Sites whose USB-tracking database uses different table/column names should
create read-only/updatable views named devices, checkinoutlog, and
users that map local columns to the names above. Example:
CREATE VIEW devices AS
SELECT
asset_tag AS device_id,
description AS device_desc,
owner AS device_owner,
state AS status,
storage_bay AS locker_location
FROM usb_assets;
Because the plugin writes to devices/checkinoutlog/users, either make the
views updatable (single-table views usually are) or expose real tables with
these column names. Grant the app account SELECT, INSERT, UPDATE.
Notes:
device_idandbadge_numberare the natural keys the plugin matches on.- If
cmmc_usbis unreachable, USB endpoints return an error and the rest of the app keeps working (the feature degrades, it does not crash the app).