The stage 5 smoke test failure was a locked config section, but not one of the two the installer unlocks. A diagnostic collected from the server returned: HTTP 500.52 - URL Rewrite Module Error Module RewriteModule, Handler httpplatformhandler Error Code 0x80070021 Config Error: This configuration section cannot be used at this path. Config File: \\?\C:\shopdb-flask\web.config handlers and httpPlatform were both overrideMode Allow and locked false, so the unlock had worked. The section at fault was a third one, system.webServer/rewrite/allowedServerVariables, which ships overrideModeDefault="Deny". web.config declared <allowedServerVariables> locally for the X-Forwarded-For rule, and IIS rejects that declaration outright, failing the entire configuration before httpPlatformHandler ran. python was therefore never launched and C:\shopdb-flask\logs stayed empty, which reads as a dead application or a permissions fault and is neither. Unlocking the section would let every site on the machine declare arbitrary server variables. The installer now adds the single variable to the server-level allow list, checking first because a duplicate add is an error, and web.config no longer declares it. The rewrite rule is unchanged. Verified by applying the installer's own uncommenting to the template and parsing the result: one rewrite element, no allowedServerVariables, the rule still setting HTTP_X_FORWARDED_FOR from REMOTE_ADDR. shopdb-diagnose.py checked only the two sections the installer unlocks, so it could not have named this one; the IIS error page did. It now reports the lock state of the rewrite sections as well.