- Strip emojis from 47 markdown files across docs/, sql/, and root - Add docs/DOCS_CONSOLIDATION_PLAN.md with plan to reduce 45 docs to 8 - Establish no-emoji rule for documentation going forward 🤖 Generated with [Claude Code](https://claude.com/claude-code) Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
9.3 KiB
9.3 KiB
Machine Relationships - Usage Examples
Date: 2025-11-06 Purpose: Show real-world examples of how machine relationships work
Example Scenario: Dualpath Lathes with Shared Controller
Setup:
- Machine 2001 (CNC Lathe)
- Machine 2002 (CNC Lathe)
- PC 500 (Shopfloor PC, hostname: PC-CNC-01)
Relationships:
- 2001 and 2002 share the same controller (dualpath)
- Both machines communicate directly with PC 500
Data Setup
Step 1: Insert Relationship Types (one-time setup)
INSERT INTO relationshiptypes (relationshiptype, description, isbidirectional) VALUES
('Dualpath', 'Machines share same controller', 1),
('Controlled By', 'Machine controlled by PC/controller', 0),
('Controls', 'PC/controller controls machine', 0);
Step 2: Link the dualpath machines
-- 2001 and 2002 are dualpath
INSERT INTO machinerelationships (relationshiptypeid, machineid1, machineid2, notes) VALUES
(1, 2001, 2002, 'Dualpath lathe pair - share controller');
Step 3: Link machines to controlling PC
-- 2001 is controlled by PC 500
INSERT INTO machinerelationships (relationshiptypeid, machineid1, machineid2, notes) VALUES
(2, 2001, 500, 'Primary CNC controller');
-- 2002 is controlled by PC 500
INSERT INTO machinerelationships (relationshiptypeid, machineid1, machineid2, notes) VALUES
(2, 2002, 500, 'Primary CNC controller');
Common Queries
Q1: Is machine 2001 dualpath? With what machine?
SELECT
m.machinenumber AS this_machine,
CASE
WHEN m2.machineid IS NOT NULL THEN 'Yes'
ELSE 'No'
END AS is_dualpath,
m2.machinenumber AS dualpath_partner,
rt.relationshiptype
FROM machines m
LEFT JOIN machinerelationships mr ON (
(mr.machineid1 = m.machineid OR mr.machineid2 = m.machineid)
AND mr.relationshiptypeid = 1
)
LEFT JOIN machines m2 ON (
CASE
WHEN mr.machineid1 = m.machineid THEN mr.machineid2
ELSE mr.machineid1
END = m2.machineid
)
LEFT JOIN relationshiptypes rt ON mr.relationshiptypeid = rt.relationshiptypeid
WHERE m.machineid = 2001;
Result:
this_machine | is_dualpath | dualpath_partner | relationshiptype
2001 | Yes | 2002 | Dualpath
Q2: Which PC controls machine 2001?
SELECT
m.machinenumber AS cnc_machine,
pc.machineid AS controller_id,
pc.machinenumber AS controller_location,
pc.hostname AS controller_hostname,
rt.relationshiptype
FROM machines m
JOIN machinerelationships mr ON mr.machineid1 = m.machineid
JOIN machines pc ON mr.machineid2 = pc.machineid
JOIN relationshiptypes rt ON mr.relationshiptypeid = rt.relationshiptypeid
WHERE m.machineid = 2001
AND mr.relationshiptypeid = 2;
Result:
cnc_machine | controller_id | controller_location | controller_hostname | relationshiptype
2001 | 500 | IT-LAB-01 | PC-CNC-01 | Controlled By
Q3: What machines does PC 500 control?
SELECT
pc.hostname AS controller,
m.machinenumber AS controlled_machine,
mt.machinetype,
mr.notes
FROM machines pc
JOIN machinerelationships mr ON mr.machineid2 = pc.machineid
JOIN machines m ON mr.machineid1 = m.machineid
JOIN machinetypes mt ON m.machinetypeid = mt.machinetypeid
WHERE pc.machineid = 500
AND mr.relationshiptypeid = 2
ORDER BY m.machinenumber;
Result:
controller | controlled_machine | machinetype | notes
PC-CNC-01 | 2001 | CNC - Lathe | Primary CNC controller
PC-CNC-01 | 2002 | CNC - Lathe | Primary CNC controller
Q4: Complete picture - Machine + Dualpath + Controller + IP
SELECT
m.machinenumber AS machine,
mt.machinetype,
-- Dualpath info
m_dual.machinenumber AS dualpath_partner,
-- Controller info
pc.hostname AS controller,
pc.machinenumber AS controller_location,
-- Controller's IP
c.address AS controller_ip
FROM machines m
JOIN machinetypes mt ON m.machinetypeid = mt.machinetypeid
-- Find dualpath partner
LEFT JOIN machinerelationships mr_dual ON (
(mr_dual.machineid1 = m.machineid OR mr_dual.machineid2 = m.machineid)
AND mr_dual.relationshiptypeid = 1
)
LEFT JOIN machines m_dual ON (
CASE
WHEN mr_dual.machineid1 = m.machineid THEN mr_dual.machineid2
ELSE mr_dual.machineid1
END = m_dual.machineid
)
-- Find controller
LEFT JOIN machinerelationships mr_ctrl ON (
mr_ctrl.machineid1 = m.machineid
AND mr_ctrl.relationshiptypeid = 2
)
LEFT JOIN machines pc ON mr_ctrl.machineid2 = pc.machineid
-- Get controller's IP address
LEFT JOIN communications c ON (
pc.machineid = c.machineid
AND c.comstypeid = 1 -- IP type
)
WHERE m.machineid IN (2001, 2002);
Result:
machine | machinetype | dualpath_partner | controller | controller_location | controller_ip
2001 | CNC - Lathe | 2002 | PC-CNC-01 | IT-LAB-01 | 192.168.1.50
2002 | CNC - Lathe | 2001 | PC-CNC-01 | IT-LAB-01 | 192.168.1.50
Recommended View: vw_machine_relationships
Create a view for easy access:
CREATE VIEW vw_machine_relationships AS
SELECT
m.machineid,
m.machinenumber,
m.alias,
mt.machinetype,
-- Dualpath info
CASE WHEN m_dual.machineid IS NOT NULL THEN 1 ELSE 0 END AS is_dualpath,
m_dual.machineid AS dualpath_partner_id,
m_dual.machinenumber AS dualpath_partner,
-- Controller info
pc.machineid AS controller_id,
pc.hostname AS controller_hostname,
pc.machinenumber AS controller_location,
-- Controller IP
c.address AS controller_ip,
-- Relationship counts
(SELECT COUNT(*)
FROM machinerelationships mr
WHERE mr.machineid1 = m.machineid OR mr.machineid2 = m.machineid
) AS total_relationships
FROM machines m
JOIN machinetypes mt ON m.machinetypeid = mt.machinetypeid
-- Dualpath partner
LEFT JOIN machinerelationships mr_dual ON (
(mr_dual.machineid1 = m.machineid OR mr_dual.machineid2 = m.machineid)
AND mr_dual.relationshiptypeid = 1
AND mr_dual.isactive = 1
)
LEFT JOIN machines m_dual ON (
CASE
WHEN mr_dual.machineid1 = m.machineid THEN mr_dual.machineid2
ELSE mr_dual.machineid1
END = m_dual.machineid
)
-- Controller PC
LEFT JOIN machinerelationships mr_ctrl ON (
mr_ctrl.machineid1 = m.machineid
AND mr_ctrl.relationshiptypeid = 2
AND mr_ctrl.isactive = 1
)
LEFT JOIN machines pc ON mr_ctrl.machineid2 = pc.machineid
-- Controller IP
LEFT JOIN communications c ON (
pc.machineid = c.machineid
AND c.comstypeid = 1
)
WHERE m.isactive = 1;
Using the View:
-- Simple query for machine 2001
SELECT * FROM vw_machine_relationships WHERE machineid = 2001;
-- Show all dualpath machines
SELECT * FROM vw_machine_relationships WHERE is_dualpath = 1;
-- Show all machines controlled by PC 500
SELECT * FROM vw_machine_relationships WHERE controller_id = 500;
ASP Code Examples
Check if machine is dualpath:
strSQL = "SELECT * FROM vw_machine_relationships WHERE machineid = ?"
Set rs = ExecuteParameterizedQuery(objConn, strSQL, Array(CLng(machineId)))
If Not rs.EOF Then
isDualpath = rs("is_dualpath")
If isDualpath = 1 Then
Response.Write("Dualpath with: " & rs("dualpath_partner"))
End If
If Not IsNull(rs("controller_hostname")) Then
Response.Write("Controller: " & rs("controller_hostname"))
Response.Write(" (IP: " & rs("controller_ip") & ")")
End If
End If
Display machine card with relationships:
<div class="machine-card">
<h3>Machine <%= rs("machinenumber") %></h3>
<p>Type: <%= rs("machinetype") %></p>
<% If rs("is_dualpath") = 1 Then %>
<div class="dualpath-badge">
<strong>Dualpath:</strong> Linked with <%= rs("dualpath_partner") %>
</div>
<% End If %>
<% If Not IsNull(rs("controller_hostname")) Then %>
<div class="controller-info">
<strong>Controller:</strong> <%= rs("controller_hostname") %><br>
<strong>Location:</strong> <%= rs("controller_location") %><br>
<strong>IP:</strong> <%= rs("controller_ip") %>
</div>
<% End If %>
</div>
Benefits of This Design
Flexible - Any machine can relate to any other machine Bidirectional - Dualpath works both ways automatically Directional - "Controlled By" has clear direction Extensible - Easy to add new relationship types Query-friendly - Simple JOINs to get related machines Unified - PCs are machines too, so PC-to-machine relationships use same table Future-proof - Supports clusters, backups, master-slave, etc.
Future Relationship Types (Examples)
INSERT INTO relationshiptypes (relationshiptype, description, isbidirectional) VALUES
('Backup', 'Backup/redundant machine', 1),
('Cluster Member', 'Member of machine cluster', 1),
('Feeds Into', 'Output feeds into next machine', 0),
('Mirror', 'Mirrored configuration', 1),
('Hot Standby', 'Hot standby/failover machine', 0);